169,742 research outputs found

    Imaging genetically-modified cells with a miniaturised multimodal optical coherence tomography + fluorescence probem

    No full text
    We describe the development of multimodal probes capable of acquiring fluorescence and optical coherence tomography signals through a single fiber. We demonstrate their use by ex vivo imaging genetically-modified cells expressing a fluorescent protein, allowing their distribution to be visually assessed within the airway.Jiawen Li, Bryden C. Quirk, Juliette Delhove, Rodney W. Kirk, Alexandra McCarron, Patricia Cmielewski, Caroline Boudoux, David Parsons, Martin Donnelley, Robert A. McLaughli

    Rapid wavelength-swept spectrally encoded confocal microscopy

    No full text
    Spectrally encoded confocal microscopy (SECM) is a technique that allows confocal microscopy to be performed through the confines of a narrow diameter optical fiber probe. We present a novel scheme for performing SECM in which a rapid wavelength swept source is used. The system allows large field of view images to be acquired at rates up to 30 frames/second. Images of resolution targets and tissue specimens acquired ex vivo demonstrate high lateral (1.4 mu m) and axial (6 mu m) resolution. Imaging of human skin was performed in vivo at depths of up to 350 mu m, allowing cellular and sub-cellular details to be visualized in real time. (c) 2005 Optical Society of America

    Going Beyond Counting First Authors in Author Co-citation Analysis

    No full text
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Mitomycin C in highly myopic eyes - Author reply

    No full text
    Ophthalmology. 2005 Feb;112(2):208-18; discussion 219. Mitomycin C modulation of corneal wound healing after photorefractive keratectomy in highly myopic eyes. Gambato C, Ghirlando A, Moretto E, Busato F, Midena E. SourceRefractive Surgery Service and Antimetabolite Therapy Research Unit, Department of Ophthalmology, University of Padova, Padova, Italy. Abstract PURPOSE: To evaluate the role of topical mitomycin C in corneal wound healing (CWH) after photorefractive keratectomy (PRK) in highly myopic eyes. DESIGN: Prospective, double-masked, randomized clinical trial. PARTICIPANTS: Seventy-two eyes of 36 patients affected by high (>7 diopters) myopia. METHODS: In each patient, one eye was randomly assigned to PRK with intraoperative topical 0.02% mitomycin C application, and the fellow eye was treated with a placebo. Postoperatively, mitomycin C-treated eyes received artificial tears (3 times daily, tapered in 3 months), whereas the fellow eye was treated with fluorometholone sodium 2% and artificial tears (3 times daily, tapered in 3 months). MAIN OUTCOME MEASURES: Uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), contrast sensitivity, manifest refraction, and biomicroscopy. Contrast sensitivity was determined using the Pelli-Robson chart. Corneal confocal microscopy documented CWH. RESULTS: Mean follow-up was 18 months (range, 12-36). No side effects or toxic effects were documented. At 12-month follow-up examination, UCVAs (logarithm of the minimum angle of resolution) were 0.4+/-0.48 and 0.5+/-0.53 (P = .03) in mitomycin C-treated eyes and corticosteroid-treated eyes, respectively. At 1 year, corneal haze developed in 20% of corticosteroid-treated eyes, versus 0% of mitomycin C-treated eyes. At 12, 24, and 36 months, corneal confocal microscopy showed activated keratocytes and extracellular matrix significantly more evident in untreated eyes (Ps = 0.004, 0.024, and 0.046, respectively). CONCLUSION: Topical intraoperative application of 0.02% mitomycin C can reduce haze formation in highly myopic eyes undergoing PRK. Comment in Ophthalmology. 2006 Feb;113(2):357; author reply 357-8

    Dispelling the Myths Behind First-author Citation Counts

    No full text
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Preliminary Evaluation of Noninvasive Microscopic Imaging Techniques for the Study of Vocal Fold Development

    No full text
    Understanding pediatric voice development and laryngeal pathology is predicated on a detailed knowledge of the microanatomy of the layered structure of the vocal fold. Our current knowledge of this microanatomy and its temporal evolution is limited by the lack of pediatric specimen availability. By providing the capability to image pediatric vocal folds in vivo, a noninvasive microscopy technique could greatly expand the existing database of pediatric laryngeal microanatomy and could furthermore make longitudinal Studies possible. A variety of natural-contrast optical imaging technologies, including optical frequency domain imaging (OFDI), full-field optical coherence microscopy (FF-OCM), and spectrally encoded confocal microscopy (SECM) have been recently developed for noninvasive diagnosis in adult patients. In this paper, we demonstrate the potential of these three techniques for laryngeal investigation by obtaining images of excised porcine vocal fold samples. In our study, OFDI allowed visualization of the vocal fold architecture deep within the tissue, from the superficial mucosa to the vocalis muscle. The micron-level resolution of SECM allowed investigation of cells and extracellular matrix fibrils from the superficial mucosa to the intermediate layer of the lamina propria (LP) (350 mu m penetration depth). The large field of view (Lip to 700 Am), penetration depth (up to 500 mu m), and resolution (2 X 2 X 1 mu m [X X Y X Z]) of FF-OCM enabled comprehensive three-dimensional evaluation of the layered structure of the LP. Our results Suggest that these techniques provide important and complementary cellular and structural information, which may be useful for investigating pediatric vocal fold maturation in vivo

    A Multi-Language Comparison of Influences on Author Verification using Character N-Grams

    No full text
    We create a new multi-language corpus for author verification based on Wikipedia talkpages, and evaluate the influence that differences in topic and time have on character n-gram author profiles. Topic alignment between two texts is found to increase author verification precision, and an authors writing style is found to change over time, but not more significantly after 3 years than after 1 year.Information ArchitectureWISElectrical Engineering, Mathematics and Computer Scienc

    A 0.12mm<sup>2</sup> Wien-Bridge Temperature Sensor with 0.1°C (3σ) Inaccuracy from -40°C to 180°C

    No full text
    Resistor-based temperature sensors can achieve much higher resolution and energy efficiency than conventional BJT-based sensors [1], but they typically occupy more area (&gt; 0.25 mm 2 ) and have lower operating temperatures (le 125 {circ} {C}) [2]-[4]. This work describes a 0.12mm 2 resistor-based sensor that uses a Wien-bridge (WB) filter to achieve 0.1 {circ} {C} (3 sigma) inaccuracy from - 40 {circ} {C} to 180 {circ} {C}. Compared to a state-of-the-art WB sensor [4], it occupies 6 × less area and achieves comparable relative accuracy over a 76% wider operating range. Session 10.3 Green Open Access added to TU Delft Institutional Repository ‘You share, we take care!’ – Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Electronic InstrumentationMicroelectronic

    A ±25A Versatile Shunt-Based Current Sensor with 10kHz Bandwidth and ±0.25% Gain Error from -40°C to 85°C Using 2-Current Calibration

    No full text
    Accurate current sensing is critical in many industrial applications, such as battery management and motor control. Precise shunt-based current sensors have been reported with gain errors of less than 1% over the industrial temperature range (-40°C to 85°C) [1]–[4]. However, since they are intended for coulomb counting, their bandwidth is limited to a few tens of Hz, making them unsuitable for battery impedance or motor-current sensing. This paper presents a current sensor with a wide (10kHz) bandwidth and a tunable temperature compensation scheme (TCS), which allows it to be flexibly used with different types of shunts while maintaining high accuracy. A low-cost room-temperature calibration scheme is proposed to optimize gain flatness over temperature by exploiting the shunt's self-heating at large currents. Over the industrial temperature range and a ±25A current range, it achieves state-of-the-art gain error (±0.25%) with both low-cost PCB and stable metal-alloy shunts.Green Open Access added to TU Delft Institutional Repository 'You share, we take care!' - Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Electronic InstrumentationMicroelectronic
    corecore