1,720,960 research outputs found
Effects of Different Inertial Measurement Unit Sensor-to-Segment Calibrations on Clinical 3-Dimensional Humerothoracic Joint Angles Estimation
Calibrating inertial measurement units (IMUs) involves converting orientation data from a local reference frame into a clinically meaningful reference system. Several solutions exist but little work has been done to compare different calibration methods with each other and an optical motion capture system. Thirteen healthy subjects with no signs of upper limb injury were recruited for this study and instrumented with IMU sensors and optical markers. Three IMU calibration methods were compared: N-pose calibration, functional calibration, and manual alignment. Subjects executed simple single-plane single-joint tasks for each upper limb joint as well as more complex multijoint tasks. We performed a 3-way analysis of variance on range of motion error, root mean squared error, and offset to assess differences between calibrations, tasks, and anatomical axes. Differences in the 3 IMU calibrations are minor and not statistically significant for most tasks and anatomical axes, with the exception of the offset interaction calibration × axes (P < .001, ηG2=.056). Specifically, manual alignment gives the best offset estimation on the abduction/adduction and internal/external rotation axes. Therefore, we recommend the use of a static N-pose calibration procedure as the preferred IMU calibration method to model the humerothoracic joint, as this setup is the simplest as it only requires accurate positioning of the trunk sensor
Vertical Jump Height Estimation Using Low-Sampling IMU in Countermovement Jumps: A Feasible Alternative to Motion Capture and Force Platforms
Vertical jump height from a countermovement jump is a widespread metric to assess the lower limb functionality. Motion capture systems and force platforms are considered gold standards to estimate vertical jump height; however, their use in ecological settings is limited. This study aimed to evaluate the feasibility of low-sampling-rate inertial measurement units as an alternative to the gold standard systems. The validity of three computational methods for IMU-based data—numerical double integration, takeoff velocity, and flight time—was assessed using data from 18 healthy participants who performed five double-leg and ten single-leg countermovement jumps. The data were simultaneously collected from a motion capture system, two force platforms, and an IMU positioned at the L5 level. The comparisons revealed that the numerical double integration method exhibited the highest correlation (0.87) and the lowest bias (2.5 cm) compared to the gold standards and excellent reliability (0.88). Although the takeoff velocity and flight time methods demonstrated comparable performances for double-leg jumps, their accuracy in single-leg jumps was reduced. Overall, the low-sampling-rate IMU with the numerical double integration method seems to be a reliable and feasible alternative for field-based countermovement jump assessment, warranting future investigation across diverse populations and jump modalities
Effects of IMU sensor-to-segment calibration on clinical 3D elbow joint angles estimation
Introduction: Inertial Measurement Units (IMU) require a sensor-to-segment calibration procedure in order to compute anatomically accurate joint angles and, thereby, be employed in healthcare and rehabilitation. Research literature proposes several algorithms to address this issue. However, determining an optimal calibration procedure is challenging due to the large number of variables that affect elbow joint angle accuracy, including 3D joint axis, movement performed, complex anatomy, and notable skin artefacts. Therefore, this paper aims to compare three types of calibration techniques against an optical motion capture reference system during several movement tasks to provide recommendations on the most suitable calibration for the elbow joint. Methods: Thirteen healthy subjects were instrumented with IMU sensors and optical marker clusters. Each participant performed a series of static poses and movements to calibrate the instruments and, subsequently, performed single-plane and multi-joint tasks. The metrics used to evaluate joint angle accuracy are Range of Motion (ROM) error, Root Mean Squared Error (RMSE), and offset. We performed a three-way RM ANOVA to evaluate the effect of joint axis and movement task on three calibration techniques: N-Pose (NP), Functional Calibration (FC) and Manual Alignment (MA). Results: Despite small effect sizes in ROM Error, NP displayed the least precision among calibrations due to interquartile ranges as large as 24.6°. RMSE showed significant differences among calibrations and a large effect size where MA performed best (RMSE = 6.3°) and was comparable with FC (RMSE = 7.2°). Offset showed a large effect size in the calibration*axes interaction where FC and MA performed similarly. Conclusion: Therefore, we recommend MA as the preferred calibration method for the elbow joint due to its simplicity and ease of use. Alternatively, FC can be a valid option when the wearer is unable to hold a predetermined posture.</p
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Preliminary Validation of an IMU-based Physiotherapy Assessment System for the Lower Extremities
Physiotherapy assessments traditionally rely on the clinician’s interpretation to evaluate musculoskeletal conditions. However, technology, such as Inertial Measurement Units (IMU), is increasingly used to assist medical professionals. This study evaluates the accuracy and reliability of the Euleria Lab (ELAB) rehabilitation system against an optical motion capture system (OPTO). 7 healthy volunteers were instrumented with 5 IMU and 22 retroreflective markers and performed lower limbs single-plane and multi-plane movements. Joint angles were used to compute Range of Motion (ROM), Root Mean Squared Error (RMSE), Bland-Altman plots and intraclass correlation coefficient (ICC). ROM and RMSE were analysed using two RM ANOVA. In multi-plane tasks, ankle, knee and hip angles were compared using Hotelling’s T2 statistical parametric mapping (SPM) test. No significant differences were found between the two systems for ROM and between tasks in terms of RMSE. However, hip rotation showed large RMSE and poor ICC reliability. Hip flexion and abduction showed good agreement and a systematic bias = 10°. Multi-joint tasks revealed significant differences only in hip flexion during lunges. Therefore, ELAB proved highly accurate and reliable for the assessment of the movements: ankle, knee, and trunk flexion, but demonstrated poor accuracy and agreement during the hip rotation movement. ELAB displayed significant biases but good agreement and minor errors during hip flexion and abduction
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
- …
