1,720,978 research outputs found

    Respiratory oscillometry testing in relation to exercise in healthy and asthmatic Thoroughbreds

    No full text
    Background: Racehorses may experience exercise-induced bronchodilation or bronchoconstriction, with potential differences between healthy and asthmatic individuals. Objectives: To identify exercise-related lung function variations by oscillometry in racehorses, compare lung function between healthy and mild equine asthma (MEA) horses, assess oscillometry's potential as a predictor of racing fitness. Study design: Prospective case-control clinical study. Methods: Fourteen Thoroughbred racehorses (5 healthy, 9 MEA) underwent a protocol including respiratory oscillometry at rest, exercise with fitness monitoring, oscillometry at 15 and 45 min post-exercise, and bronchoalveolar lavage fluid (BALf) cytology. Oscillometry parameters (resistance [Rrs] and reactance [Xrs]) were compared within and between healthy and MEA groups at different timepoints. Associations between Rrs and Xrs at rest and 15 min post-exercise and BALf cytology and fitness indices were evaluated. Results: MEA horses showed higher Rrs at 15 min post-exercise (0.6 ± 0.2 cmH2 O/L/s) than healthy horses (0.3 ± 0.1 cmH2 O/L/s) (p < 0.01). In healthy horses, Rrs decreased at 15 min post-exercise compared with resting values (0.5 ± 0.1 cmH2 O/L/s) (p = 0.04). In MEA horses, oscillometry parameters did not vary with time. Post-exercise Xrs inversely correlated with total haemosiderin score (p < 0.01, r2 = 0.51). Resting Rrs inversely correlated with speed at 200 bpm (p = 0.03, r2 = -0.61), and Xrs with maximum heart rate (HR) during exercise (p = 0.02, r2 = -0.62). Post-exercise Rrs inversely correlated with mean (p = 0.04, r2 = -0.60) and maximum speed (p = 0.04, r2 = -0.60), and HR variability (p < 0.01, r2 = -0.74). Main limitations: Small sample size, oscillometry repeatability not assessed, potential interference of upper airway obstructions, external variables influencing fitness indices. Conclusions: Oscillometry identified lung function differences between healthy and MEA horses at 15 min post-exercise. Only healthy horses exhibited exercise-induced bronchodilation. Oscillometry showed potential in predicting subclinical airway obstruction

    Differences in pulmonary function measured by oscillometry between horses with mild-moderate equine asthma and healthy controls

    No full text
    Background: The diagnosis of mild-moderate equine asthma (MEA) can be confirmed by airway endoscopy, bronchoalveolar lavage fluid (BALf) cytology, and lung function evaluation by indirect pleural pressure measurement. Oscillometry is a promising pulmonary function test method, but its ability to detect subclinical airway obstruction has been questioned. Objectives: To evaluate the differences in lung function measured by oscillometry between healthy and MEA-affected horses. Study design: Prospective case-control clinical study. Methods: Thirty-seven horses were divided into healthy and MEA groups, based on history and clinical score; the diagnosis of MEA was confirmed by airway endoscopy and BALf cytology. Horses underwent oscillometry at frequencies ranging from 2 to 6 Hz. Obtained parameters included whole-breath, inspiratory, expiratory, and the difference between inspiratory and expiratory resistance (Rrs) and reactance (Xrs). Differences between oscillometry parameters at different frequencies were evaluated within and between groups by repeated-measures two-way ANOVA and post hoc tests with Bonferroni correction. Frequency dependence was compared between groups by t test. For significant parameters, a receiver operating characteristics curve was designed, cut-off values were identified and their sensitivity and specificity were calculated. Statistical significance was set at p < 0.05. Results: No significant differences in Xrs and Rrs were observed between groups. The frequency dependence of whole-breath and inspiratory Xrs significantly differed between healthy (respectively, -0.03 +/- 0.02 and -0.05 +/- 0.02 cmH(2)O/L/s) and MEA (-0.1 +/- 0.03 and -0.2 +/- 0.02 cmH(2)O/L/s) groups (p < 0.05 and p < 0.01). For inspiratory Xrs frequency dependence, a cut-off value of -0.06 cmH(2)O/L/s was identified, with 86.4% (95% CI: 66.7%-95.3%) sensitivity and 66.7% (95% CI: 41.7%-84.8%) specificity. Main limitations: Sample size, no BALf cytology in some healthy horses. Conclusions: Oscillometry can represent a useful non-invasive tool for the diagnosis of MEA. Specifically, the evaluation of the frequency dependence of Xrs may be of special interest

    BENEFITS OF INTRATRACHEAL AND EXTRATHORACIC HIGH-FREQUENCY PERCUSSIVE VENTILATION IN A MODEL OF CAPNOPERITONEUM

    No full text
    : Abdominal inflation with CO2 is used to facilitate laparoscopic surgeries, however providing adequate mechanical ventilation in this scenario is of major importance during anesthesia management. We characterized high frequency percussive ventilation (HFPV) in protecting from the gas exchange and respiratory mechanical impairments during capnoperitoneum. In addition, we aimed to assess the difference between conventional pressure-controlled mechanical ventilation (CMV) and HFPV modalities generating the high-frequency signal intratracheally (HFPVi) or extrathoracally (HFPVe). Anesthetized rabbits (n=16) were mechanically ventilated by random sequences of CMV, HFPVi, and HFPVe. The ventilator superimposed the conventional waveform with two high frequency signals (5 Hz and 10 Hz) during intratracheal HFPV (HFPVi) and HFPV with extrathoracic application of oscillatory signals through a sealed chest cuirass (HFPVe). Lung oxygenation index (PaO2/FiO2), arterial partial pressure of carbon dioxide (PaCO2), intrapulmonary shunt (Qs/Qt), and respiratory mechanics were assessed before abdominal inflation, during capnoperitoneum, and after abdominal deflation. Compared with CMV, HFPVi with additional 5-Hz oscillations during capnoperitoneum resulted in higher PaO2/FiO2, lower PaCO2, and decreased Qs/Qt. These improvements were smaller but remained significant during HFPVi with 10 Hz and HFPVe with either 5 or 10 Hz. The ventilation modes did not protect against capnoperitoneum-induced deteriorations in respiratory tissue mechanics. These findings suggest that high frequency oscillations combined with conventional pressure-controlled ventilation improved lung oxygenation and CO2 removal in a model of capnoperitoneum. Compared with extrathoracic pressure oscillations, intratracheal generation of oscillatory pressure bursts appeared more effective. These findings may contribute to the optimization of mechanical ventilation during laparoscopic surgery

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
    corecore