1,720,979 research outputs found
Informed Distributed Space Assets Design on Multi-Body Quasi-Periodic Tori by Means of Engineering Properties Mapping Techniques
Nonlinear Dynamic System Identification in the Spectral Domain Using Particle-Bernstein Polynomials
System identification (SI) is the discipline of inferring mathematical models from unknown dynamic systems using the input/output observations of such systems with or without prior knowledge of some of the system parameters. Many valid algorithms are available in the literature, including Volterra series expansion, Hammerstein–Wiener models, nonlinear auto-regressive moving average model with exogenous inputs (NARMAX) and its derivatives (NARX, NARMA). Different nonlinear estimators can be used for those algorithms, such as polynomials, neural networks or wavelet networks. This paper uses a different approach, named particle-Bernstein polynomials, as an estimator for SI. Moreover, unlike the mentioned algorithms, this approach does not operate in the time domain but rather in the spectral components of the signals through the use of the discrete Karhunen–Loève transform (DKLT). Some experiments are performed to validate this approach using a publicly available dataset based on ground vibration tests recorded from a real F-16 aircraft. The experiments show better results when compared with some of the traditional algorithms, especially for large, heterogeneous datasets such as the one used. In particular, the absolute error obtained with the prosed method is 63% smaller with respect to NARX and from 42% to 62% smaller with respect to various artificial neural network-based approaches
A multi-channel electromyography, electrocardiography and inertial wireless sensor module using bluetooth low-energy
This paper proposes a wireless sensor device for the real-time acquisition of bioelectrical signals such as electromyography (EMG) and electrocardiography (ECG), coupled with an inertial sensor, to provide a comprehensive stream of data suitable for human activity detection, motion analysis, and technology-assisted nursing of persons with physical or cognitive impairments. The sensor is able to acquire up to three independent bioelectrical channels (six electrodes), each with 24 bits of resolution and a sampling rate up to 3.2 kHz, and has a 6-DoF inertial platform measuring linear acceleration and angular velocity. The bluetooth low-energy wireless link was chosen because it allows easy interfacing with many consumer electronics devices, such as smartphones or tablets, that can work as data aggregators, but also imposes data rate restrictions. These restrictions are investigated in this paper as well, together with the strategy we adopted to maximize the available bandwidth and reliability of the transmission within the limits imposed by the protocol
High-Accuracy Clock Synchronization in Low-Power Wireless sEMG Sensors
Wireless surface electromyography (sEMG) sensors are very practical in that they can be worn freely, but the radio link between them and the receiver might cause unpredictable latencies that hinder the accurate synchronization of time between multiple sensors, which is an important aspect to study, e.g., the correlation between signals sampled at different sites. Moreover, to minimize power consumption, it can be useful to design a sensor with multiple clock domains so that each subsystem only runs at the minimum frequency for correct operation, thus saving energy. This paper presents the design, implementation, and test results of an sEMG sensor that uses Bluetooth Low Energy (BLE) communication and operates in three different clock domains to save power. In particular, this work focuses on the synchronization problem that arises from these design choices. It was solved through a detailed study of the timings experimentally observed over the BLE connection, and through the use of a dual-stage filtering mechanism to remove timestamp measurement noise. Time synchronization through three different clock domains (receiver, microcontroller, and ADC) was thus achieved, with a resulting total jitter of just 47 mu s RMS for a 1.25 ms sampling period, while the dedicated ADC clock domain saved between 10% to 50% of power, depending on the selected data rate
Energy and Performance Analysis of Lossless Compression Algorithms for Wireless EMG Sensors
Electromyography (EMG) sensors produce a stream of data at rates that can easily saturate a low-energy wireless link such as Bluetooth Low Energy (BLE), especially if more than a few EMG channels are being transmitted simultaneously. Compressing data can thus be seen as a nice feature that could allow both longer battery life and more simultaneous channels at the same time. A lot of research has been done in lossy compression algorithms for EMG data, but being lossy, artifacts are inevitably introduced in the signal. Some artifacts can usually be tolerable for current applications. Nevertheless, for some research purposes and to enable future research on the collected data, that might need to exploit various and currently unforseen features that had been discarded by lossy algorithms, lossless compression of data may be very important, as it guarantees no extra artifacts are introduced on the digitized signal. The present paper aims at demonstrating the effectiveness of such approaches, investigating the performance of several algorithms and their implementation on a real EMG BLE wireless sensor node. It is demonstrated that the required bandwidth can be more than halved, even reduced to 1/4 on an average case, and if the complexity of the compressor is kept low, it also ensures significant power savings
Recurrent neural network for human activity recognition in embedded systems using ppg and accelerometer data
Photoplethysmography (PPG) is a common and practical technique to detect human activity and other physiological parameters and is commonly implemented in wearable devices. However, the PPG signal is often severely corrupted by motion artifacts. The aim of this paper is to address the human activity recognition (HAR) task directly on the device, implementing a recurrent neural network (RNN) in a low cost, low power microcontroller, ensuring the required performance in terms of accuracy and low complexity. To reach this goal, (i) we first develop an RNN, which integrates PPG and tri-axial accelerometer data, where these data can be used to compensate motion artifacts in PPG in order to accurately detect human activity; (ii) then, we port the RNN to an embedded device, Cloud-JAM L4, based on an STM32 microcontroller, optimizing it to maintain an accuracy of over 95% while requiring modest computational power and memory resources. The experimental results show that such a system can be effectively implemented on a constrained-resource system, allowing the design of a fully autonomous wearable embedded system for human activity recognition and logging
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
- …
