1,720,990 research outputs found
Feasibility of a left atrial electrical disconnection procedure for atrial fibrillation using transcatheter radiofrequency ablation
INTRODUCTION:
Transcatheter Left Atrial Electrical Disconnection. An effective, catheter-based treatment for persistent atrial fibrillation (AF) remains elusive. This study assessed the feasibility of transcatheter left atrial (LA) electrical disconnection and its effect on AF inducibility. METHOD AND RESULTS:
Thirteen anesthetized swine underwent noncontact mapping of the right atrium (RA) during coronary sinus (CS) pacing. Sites of earliest RA activation were identified using isopotential maps. An ablation catheter was navigated to these sites and a cluster of radiofrequency (RF) lesions applied until earliest activation shifted to a new site. The procedure was repeated until the atria were electrically disconnected. AF induction was attempted before and after ablation. Earliest RA activation was the CS os during proximal CS pacing and Bachmann's bundle during distal CS pacing. These two sites were successfully ablated in all 13 animals. Earliest activation then shifted to the fossa ovalis. RF energy was applied at a median of 2.5 sites (range 1 to 5) around the fossa, then at sites in the triangle of Koch, septum, cavotricuspid isthmus, and posterior wall. Atrial electrical disconnection was achieved in 10 of 13 animals (5 LA electrical disconnection, 3 RA electrical disconnection, 2 biatrial electrical disconnection with complete heart block). After atrial electrical disconnection, the LA became electrically silent. Before ablation, AF was inducible in every animal. After atrial electrical disconnection, AF was inducible in 3 of 10 animals. CONCLUSION:
Atrial electrical disconnection is feasible using noncontact mapping and RF ablation. Successful electrical disconnection of the atria reduces AF inducibility. This approach is worthy of further evaluation as a management strategy for persistent AF, combined with device therapies
High altitude arrhythmias
Objective: To investigate the cause and nature of palpitations occurring at high altitude. Methods: Implantable loop recorders were inserted subcutaneously in the left pectoral region of 9 healthy male volunteers. Subjects flew to Kathmandu (1,250 m) and then Lukla (2,800 m) before immediately commencing an identical ascent and descent profile to high altitude. The loop recorders were activated with any episode of palpitations and during exercise, rest and sleep. Arterial oxygen saturation was assessed concomitant with device activation. Results: Above 5,000 m all subjects reported palpitations during exercise. All subjects demonstrated sinus tachycardia and marked sinus arrhythmia; one subject demonstrated atrial flutter; one subject had non-conducted p waves, and a further subject had marked ST segment depression. Conclusions: Significant arrhythmias occur at high altitude. In view of the increased risk of sudden cardiac death at high altitude, and considering that the elderly account for 15% of the 100 million visitors to altitude annually, further investigation is require
Comparison of coronary venous defibrillation with conventional transvenous internal defibrillation in man
Animal studies have shown that defibrillation in coronary veins is more effective than in the right ventricle. We aimed to assess the feasibility of placing defibrillation electrodes in the middle cardiac vein (MCV) in man and its impact on defibrillation requirements.
Methods: A prospective randomised study conducted in a tertiary referral centre. 10 patients (9 male) undergoing ICD implantation (65 (12) yrs) for NASPE/BPEG indications were studied. Defibrillation thresholds (DFT) were measured, using a binary search and an external defibrillator after 10 seconds of ventricular fibrillation, for the following configurations in each patient (order of testing randomised): RV + MCV rarr Can and RV rarr SVC + Can.
Interventions: A dual coil defibrillation electrode was placed transvenously in the right ventricle (RV) in the conventional manner. Using a guiding catheter a 3.2 Fr (67.5 mm length) electrode was placed transvenously in MCV. A test-can was placed subcutaneously in the left pectoral region.
Results: Lead placement was possible in 8/10 pts. Time to perform a middle cardiac venogram and place the electrode was 21 (23) mins. No adverse events were observed. Defibrillation current was less (6.7 (2.7) A) with RV + MCV rarr Can compared to the conventional RV rarr SVC + Can configuration (8.9 (3.4) A, p = 0.03). There was no significant difference in defibrillation voltage or energy. However, shock impedance was higher in the former configuration (57 (10) v. 43 (6) OHgr, p = 0.001).
Conclusions: In the majority of cases placement of a defibrillation lead in MCV is feasible. Defibrillation current requirements are 25% less when the shock is delivered using a MCV electrode
Development of indications for cardiac resynchronisation therapy in the implantable cardioverter defibrillator population
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
- …
