1,720,957 research outputs found

    A novel computational tool for the analysis of implant positioning effects in cementless total hip replacements

    No full text
    Implant positioning is a critical factor in assuring the primary stability of cementless Total Hip Replacements (THRs). Although it is under the direct control of surgeons, finding the optimal implant position and achieving a perfect fit remain a challenge even with the advent of computer navigation. Placement of the femoral stem in an excessive ante/retroversion or varus/valgus orientation can be detrimental to the performance of THR. To determine the effect of such malalignment, finite element (FE) computer modelling is often used. However, this can be time consuming since FE meshes must be repeatedly generated and solved each time for a range of defined implant positions. In the present study, a mesh morphing technique is developed for the automatic generation of FE models of the implanted femur; in this way, many implant orientations can be investigated in a single analysis.An average femur geometry generated from a CT scan population of 13 male and 8 female patients aged between 43 and 84 years was considered. The femur was virtually implanted with the Furlong HAC titanium alloy stem (JRI Ltd, Sheffield, UK) and placed in the medullary canal in a baseline neutral nominal position. The head of the femur was then removed and both femur and implant volumes were joined together to form a single piece that was exported into ANSYS11 ICEM CFD (ANSYS Inc., 2008) for meshing. To adequately replicate implant ante/retroversion, varus/valgus or anterior/posterior orientations, the rigid body displacement of the implant was controlled by three rotations with respect to a local coordinate system. One hundred different implant positions were analysed and the quality of the morphed meshes analysed for consistency.To check the morphed meshes, corresponding models were generated individually by re-positioning the implant in the femur. Selected models were solved to predict the strain distribution in the bone and the bone-implant relative micromovements under joint and muscle loading. A good agreement was found for bone strains and implant micromotions between the morphed models and their individually run counterparts. In the post-processing stage further metrics were analysed to corroborate the findings of the morphed and individually run models. These included: average and maximum strains in bone interface area and its entire volume, percentage of bone interface area and its volume strained up to and beyond 0.7%; implant average and maximum micromotions and finally percentages of implant area undergoing reported critical micromotions of 50 ?m, 100 ?m and 150 ?m for bone ingrowth. Excellent correlation was observed in all cases.In conclusion, the proposed technique allowed an automatic generation of FE meshes of the implanted femur as the implant position varies; the required computational resources were considerably reduced and the biomechanical response was evaluated. This model forms a good basis for the development of a tool for multiple statistical analyses of the effects of implant orientation in pre-clinical studies<br/

    Rapid analysis of implant positioning effects in cementless total hip replacements

    No full text
    Implant positioning plays an important role in the success of cementless THRs in the early postoperative stage. Variability in positioning might be inevitable even with better pre-operative planning softwares or computer navigation. Combining multiple CAD operations and Finite Element (FE) simulations can help to capture variability effects. In the present study, FE meshes of the implanted femur were automatically generated for a range of pre-defined femur-implant configurations. Predicted micromovements at the femur-implant interface were then used to construct surrogate models to (a) compute the sensitivities of three biomechanical metrics to implant orientations and (b) identify the best and worst implant positions<br/

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado
    corecore