1,721,039 research outputs found

    A site-specific controlled-release system for metformin

    No full text
    Oral absorption of the antihyperglycaemic agent metformin hydrochloride (MF-HCI) is confined to the upper part of the intestine, therefore rational controlled-release formulations of this drug should ensure a complete release during transit from stomach to jejunum. The aim of this study was the preparation of a system able to sustain release of high MF-HCI doses in compliance with the above requirement. Matrices (6mm diameter; 50 mg weight) comprising varying drug-Precirol ATO 5 ratios were prepared by compression. The matrix containing 70% drug was coated on one face with Eudragit L100-55. Drug release to simulated gastric (SGF), jejunal (SJF) and ileal (SIF) fluids in sequence was studied using a modified USP rotating basket method. Release depended on drug load whereas it was independent of dissolution medium pH and hydrodynamics. Release kinetics were of √t type and were determined by drug diffusion in aqueous pores created in the matrix by drug dissolution. An equation correlating rate-determining factors was developed, whereby the release pattern could be optimized. The half-coated matrix started release in SGF and completed it in SJF. The half-coated matrix, synchronizing drug release and matrix transit across the small intestine, may improve drug bioavailability and reduce side effects

    Detection and decontamination of Mycobacterium chimaera and other non-tuberculosis mycobacteria in heater–cooler devices used in cardiopulmonary bypass: a Manufacturer and National guidelines summary, and a potential resolution to the problem requiring further investigation

    Full text link
    Since 2011, invasive infections due to Mycobacterium chimaera have been diagnosed in patients with previous cardiac surgery. The use of heating/cooling devices (heater–cooler units), necessary to regulate the blood temperature in extra-corporeal circulation, has been identified as a source of contaminated aerosol. Adhering to a strict maintenance program according to the manufacturer’s instructions for use including sanitizing is essential to reduce the risk. Current manufacturer guidelines and national recommendations for detection and decontamination of Mycobacterium chimaera and other non-tuberculosis mycobacteria should organically update units’ policies and protocols as they are published

    Experimental evaluation of aerosol production after dental ultrasonic instrumentation: An analysis on fine particulate matter perturbation

    Full text link
    Aerosol production represents a major concern during the majority of dental procedures. The aim of the present study is to investigate the dynamics of aerosol particles after 15 min of continuous supragingival ultrasonic instrumentation with no attempt of containment through particle count analysis. Eight volunteers were treated with supragingival ultrasonic instrumentation of the anterior buccal region. A gravimetric impactor was positioned 1 m away and at the same height of the head of the patient. Particles of different sizes (0.3–10 μm) were measured at the beginning of instrumentation, at the end of instrumentation (EI), and then every 15 min up to 105 min. The 0.3-μm particles showed non-significant increases at 15/30 min. The 0.5–1-μm particles increased at EI (p < 0.05), and 0.5 μm remained high for another 15 min. Overall, all submicron aerosol particles showed a slow decrease to normal values. Particles measuring 3–5 μm showed non-significant increases at EI. Particles measuring 10 μm did not show any increases but a continuous reduction (p < 0.001 versus 0.3 μm, p < 0.01 versus 0.5 μm, and p < 0.05 versus 1–3 μm). Aerosol particles behaved differently according to their dimensions. Submicron aerosols peaked after instrumentation and slowly decreased after the end of instrumentation, whilst larger particles did not show any significant increases. This experimental study produces a benchmark for the measurement of aerosol particles during dental procedures and raises some relevant concerns about indoor air quality after instrumentation

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
    corecore