1,720,980 research outputs found

    CathROB: A Highly Compact and Versatile Remote Catheter Navigation System

    Full text link
    Several remote catheter navigation systems have been developed and are now commercially available. However, these systems typically require specialized catheters or equipment, as well as time-consuming operations for the system set-up. In this paper, we present CathROB, a highly compact and versatile robotic system for remote navigation of standard tip-steerable electrophysiology (EP) catheters. Key features of CathROB include an extremely compact design that minimizes encumbrance and time for system set-up in a standard cath lab, a force-sensing mechanism, an intuitive command interface, and functions for automatic catheter navigation and repositioning. We report in vitro and in vivo animal evaluation of CathROB. In vitro results showed good accuracy in remote catheter navigation and automatic repositioning (1.5 ± 0.6 mm for the left-side targets, 1.7 ± 0.4 mm for the right-side targets). Adequate tissue contact was achieved with remote navigation in vivo. There were no adverse events, including absence of cardiac perforation or cardiac damage, indicative of the safety profile of CathROB. Although further preclinical and clinical studies are required, the presented CathROB system seems to be a promising solution for an affordable and easy-to-use remote catheter navigation

    A Novel Sensorized Heart Valve Prosthesis: Preliminary In Vitro Evaluation

    Full text link
    Background: Recent studies have shown that subclinical valve thrombosis in heart valve prosthesis (HVP) can be responsible for reduced leaflet motion detectable only by advanced imaging diagnostics. We conceived a novel sensorized HVP able to detect earlier any thrombus formation that may alter the leaflets motion using an electric impedance measurement, IntraValvular Impedance (IVI). Methods: For IVI measurement, dedicated electrodes are embedded in the structure of the HVP to generate a local electric field that is altered by the moving valve leaflets during their cyclic opening/closing. We present preliminary in vitro results using a first prototype of sensorized mechanical heart valve connected to an external impedance measurement system. The prototype was tested on a circulatory mock loop system and the IVI signals were recorded during both normal dynamics and experimentally induced altered working of the leaflets. Results: Recordings showed a very repetitive and stable IVI signal during the normal cyclic opening/closing of the HVP. The induced alterations in leaflet motion were reflected in the IVI signal. Conclusions: The novel sensorized HVP has great potential to give early warning of possible subclinical valve thrombosis altering the valve leaflet motion, and to help in tailoring the anticoagulation therapy

    Quantitative Approach for the Analysis of Fusional Convergence Using Eye-Tracking and SacLab Toolbox

    Full text link
    Fusional vergence is a disjunctive movement of the eyes that is made in order to obtain single vision. (e aim of the study was to provide a quantitative and objective approach for analyzing the fusional convergence response using eye tracking (ET) technology and automatic data analysis provided by the intuitive SacLab toolbox previously developed by our group. We evaluated the proposed approach in a population of 26 subjects with normal binocular vision, who were tested with base-out prisms (magnitudes 4Δ, 6Δ, and 10Δ) in order to elicit fusional convergence response. Eye movements were recorded using the Viewpoint ET and analyzed using SacLab. Parameters describing both the vergence and the version components of the fusional response (convergence duration, CD; peak convergence velocity, PCV; number of intrusive saccades, NS; and mean saccadic amplitude, MSA) were automatically calculated and provided to clinicians for an objective evaluation. Results showed that the number of subjects achieving fusional convergence decreased with prism magnitude. For subjects achieving fusion CD and PCV increased significantly (p < 0.05) when increasing the prism magnitude. For NS and MSA, there were no significant changes when passing to 6Δ, but a significant increase resulted when passing to 10Δ (p < 0.05). Noninvasive ET associated with the intuitive SacLab toolbox may represent a valid option to objectively characterize the fusional vergence response in clinical setting. (e analysis may be extended to patients with vergence disorders

    Pretreatment tumor volume and tumor sphericity as prognostic factors in patients with oral cavity squamous cell carcinoma

    No full text
    Purpose: This study was designed as a retrospective observational study, focusing on the correlation between the preoperative CT-scan tumor volume, tumor sphericity, and the disease-related prognosis. Methods: A total of 30 consecutive patients, affected by primary oral cancer, were retrospectively identified from our oral cancer database. The preoperative images (DICOM data) for the study population were uploaded into a modular software package designed to convert patients’ medical images into 3D digital models. Multislice interpolation and threshold segmentation tools were used to segment the tumor mass. This was then converted into a 3D mesh and exported in STL format, in order to calculate the corresponding volume. We applied the concept of sphericity — a measurement of how closely the shape of an object approaches that of a mathematically perfect sphere — to the segmented tumor mass. Results: Mean tumor volume was larger in patients with tumor recurrence and/or who had died than in patients who were disease free/alive. Tumor sphericity was influential on clinical outcomes. It appeared to be lower in patients who had tumor recurrence and/or who had died (0.54 ± 0.09 and 0.53 ± 0.05) than in patients who were disease free/alive (0.65 ± 0.07). This difference was statistically significant (p < 0.05). Cumulative recurrence-free survival was 86.2% for patients with a tumor volume lower than the cut-off value. Otherwise, it was 0% for those with a tumor volume higher than the cut-off value (p < 0.01; log rank test). Cumulative recurrence-free survival was 86.3% for patients with a higher sphericity index, compared with 13.6% for those with a lower sphericity index. Conclusion: The prognostic model, based on a tridimensional, CT-based characterization of the tumor size, which includes both tumor volume and tumor sphericity, uses readily available information and could be considered when formulating prognoses for patients with oral cancer

    Gaze Trajectory Index (GTI): A novel metric to quantify saccade trajectory deviation using eye tracking

    No full text
    Background: Many different indexes have been proposed to quantify saccade curvature based on geometric properties of the saccade trajectory projected on the 2D plane. We introduce the Gaze Trajectory Index (GTI), a novel metric to quantify saccade trajectory deviation based on calculation of the rotational eye movements performed in 3D space while following a 2D saccade trajectory recorded with eye tracking (ET). Methods: We provided a description of GTI calculation. In 13 subjects with normal binocular vision we assessed GTI in single-target tests, then we evaluated GTI against previously proposed metrics (Maximum Deviation,MD; Area Curvature,AC; Quadratic Curvature,QC; Initial Direction,ID) using a distractor paradigm that elicited two types of saccade deviations, i.e.“inner-curved” and “outer-curved” saccades. Results: In single-target tests GTI showed that saccade curvature was significantly higher for oblique than for vertical saccades (0.86°±0.32 vs 0.55°±0.60,p < 0.05) and higher for vertical than for horizontal saccades (0.55°±0.60 vs 0.23°±0.17,p < 0.05), in accordance with previous studies. In distractor-based tests, for inner-curved saccades, GTI strongly correlated with MD (r = 0.965,p < 0.01), AC (r = 0.940,p < 0.01), QC (r = 0.866,p < 0.01), and Principal Component Analysis (PCA) confirmed that all these metrics reflect the same underlying phenomenon. For outer-curved trajectories, GTI showed poor correlation with MD and AC (r = 0.291 and 0.416,p < 0.01), however PCA included the three metrics in the same first component group. For outer-curved trajectories, GTI was the only metric showing strong correlation (r = 0.950,p < 0.05) with the overshoot degree of the trajectory. Conclusion: The novel GTI seems to have adjunctive potential, particularly for outer-curved trajectories, in the estimation of the absolute amount of saccade trajectory deviation

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Assessment of a novel patient-specific 3D printed multi-material simulator for endoscopic sinus surgery

    Full text link
    Background: Three-dimensional (3D) printing is an emerging tool in the creation of anatomical models for surgical training. Its use in endoscopic sinus surgery (ESS) has been limited because of the difficulty in replicating the anatomical details. Aim: To describe the development of a patient-specific 3D printed multi-material simulator for use in ESS, and to validate it as a training tool among a group of residents and experts in ear-nose-throat (ENT) surgery. Methods: Advanced material jetting 3D printing technology was used to produce both soft tissues and bony structures of the simulator to increase anatomical realism and tactile feedback of the model. A total of 3 ENT residents and 9 ENT specialists were recruited to perform both non-destructive tasks and ESS steps on the model. The anatomical fidelity and the usefulness of the simulator in ESS training were evaluated through specific questionnaires. Results: The tasks were accomplished by 100% of participants and the survey showed overall high scores both for anatomy fidelity and usefulness in training. Dacryocystorhinostomy, medial antrostomy, and turbinectomy were rated as accurately replicable on the simulator by 75% of participants. Positive scores were obtained also for ethmoidectomy and DRAF procedures, while the replication of sphenoidotomy received neutral ratings by half of the participants. Conclusion: This study demonstrates that a 3D printed multi-material model of the sino-nasal anatomy can be generated with a high level of anatomical accuracy and haptic response. This technology has the potential to be useful in surgical training as an alternative or complementary tool to cadaveric dissection
    corecore