1,720,958 research outputs found
Recommended from our members
Accuracy of autorefraction in an adult Indian population.
PurposeAutorefractors allow non-specialists to quickly assess refractive error, and thus could be a useful component of large-scale vision screening programs. In order to better characterize the role of autorefraction for public health outreach programs in resource-limited settings, the diagnostic accuracy of two autorefractors was assessed relative to subjective refraction in an adult Indian population.MethodsAn optometrist refracted a series of patients aged ≥50 years at an eye clinic in Bangalore, India using the Nidek ARK-900 autorefractor first, followed by the 3nethra Royal autorefractor, and then subjective refraction. The diagnostic accuracy of each autorefractor for myopia, hyperopia, and astigmatism was assessed using subjective refraction as the reference standard, and measures of agreement between refractions were calculated.ResultsA total of 197 eyes in 104 individuals (mean age 63 ± 8 years, 52% female) were evaluated. Both autorefractors produced spherical equivalent estimates that were on average more hyperopic than subjective refraction, with a measurement bias of +0.16 D (95%CI +0.09 to +0.23D) for Nidek and +0.42 D (95%CI +0.28 to +0.54D) for 3nethra. When comparing pairs of measurements from autorefraction and subjective refraction, the limits of agreement were approximately ±1D for the Nidek autorefractor and ±1.75D for the 3Nethra autorefractor. The sensitivity and specificity of detecting ≥1 diopter of myopia were 94.6% (95%CI 86.8-100%) and 92.5% (95%CI 88.9-97.5%) for the Nidek, and 89.2% (95%CI 66.7-97.4) and 77.5% (95%CI 71.2-99.4%) for the 3Nethra. The accuracy of each autorefractor increased at greater levels of refractive error.ConclusionsThe sensitivity and specificity of the Nidek autorefractor for diagnosing refractive error among adults ≥50 years in an urban Indian clinic was sufficient for screening for visually significant refractive errors, although the relatively wide limits of agreement suggest that subjective refinement of the eyeglasses prescription would still be necessary
The patterns of uveitis and the factors affecting visual outcome from Chulalongkorn University Uveitis Cohort (CU(2)C): A 5-year longitudinal study protocol
BACKGROUND: In Thailand, several novel laboratory investigations are recently available to help differentiate the uveitic etiologies. The update on uveitis epidemiological data in Thailand is necessary to better understand the disease burden and provide guidance on management. The current study aims to describe the prevalence and identify factors associated with poor visual outcomes of uveitis patients at a tertiary center in Thailand. METHODS: A 5-year-prospective study of uveitis cases presented at a tertiary referral center in the central region of Thailand is conducted
Age dependent normative data of vertical and horizontal reflexive saccades
Purpose: There is some controversy whether or not saccades change with age. This cross-sectional study aims to clarify the characteristics of reflexive saccades at various ages to establish a normative cohort in a standardized set-up. Second objective is to investigate the feasibility of saccadometry in daily ophthalmological practice.
Methods: One hundred healthy participants aged between 6 and 76 years underwent an ophthalmologic examination and saccadometry, using an infrared video-oculography device, sampling at 220 Hz. The reflexive saccades were evoked in four directions and three target displacements each (5°/15°/30° horizontally and of 5°/10°/20° vertically). Saccadic peak velocity, gain (amplitude/target displacement) and latency were measured.
Results: Mean peak velocity of saccades was 213°/s (± 29°/s), 352°/s (± 50°/s) and 455°/s (± 67°/s) to a target position 5°, 15°and 30° horizontally, respectively, and 208°/s (± 36°/s), 303°/s (± 50°/s) and 391°/s (± 71°/s) to a target position 5°, 10° and 20° vertically. The association between peak velocity and eccentricity proved to be present at any age in all four directions. We found no relevant effect of age on peak velocity, gain and latency in a fitted linear mixed model. However, latency becomes shorter during childhood and adolescence, while in adulthood it is relatively stable with a slight trend to increase in the elderly. Saccades are more precise when the target displacement is small. Isometric saccades are most common, followed by hypometric ones. All children and elderly were able to perform good quality saccadometry in a recording time of approximately 10 minutes.
Conclusion: The presented data may serve as normative control for further studies using such a video-oculography device for saccadometry. The means of peak velocity and the gain can be used independently from age respecting the target displacement. Latency is susceptible to age
Evaluation of a Virtual Reality implementation of a binocular imbalance test.
The purpose of this study was (1) to implement a test for binocular imbalance in a Virtual Reality headset, (2) to assess its testability, reliability and outcomes in a population of clinical patients and (3) to evaluate the relationships of interocular acuity difference, stereoacuity and binocular imbalance to amblyogenic risk factors. 100 volunteers (6 to 70 years old, mean 21.2 ± 16.2), 21 with no amblyogenic risk factors and 79 with amblyopia or a history of amblyopia participated. Participants were classified by amblyogenic risk factor (24 anisometropic, 25 strabismic and 30 mixed) and, for those with strabismus, also by refractive response (16 accommodative and 39 non-accommodative). We characterized our sample using three variables, called the 'triplet' henceforth: interocular acuity difference, stereoacuity and imbalance factor. Binocular imbalance showed high test-retest reliability (no significant difference between test and retest in a subgroup, n = 20, p = 0.831); was correlated with Worth 4 dots test (r = 0.538, p<0.0001); and correlated with both interocular acuity difference (r = 0.575, p<0.0001) and stereoacuity (r = 0.675, p<0.0001). The mean values of each variable of the triplet differed depending on group classification. Mixed and non-accommodative groups showed the worst mean values compared with the other groups. Among participants with strabismus, strabismic vs mixed subgroups did not show significant differences in any variable of the triplet, whereas the accommodative vs non-accommodative subgroups showed significant differences in all of them. According to a univariate logistic model, any variable of the triplet provides a good metric for differentiating patients from controls, except for binocular imbalance for anisometropic subgroup. The proposed binocular imbalance test is feasible and reliable. We recommend monitoring amblyopia clinically not only considering visual acuity, but also stereoacuity and interocular imbalance. Stereoacuity on its own fails because of the high percentage of patients with no measurable stereoacuity. Binocular imbalance may help to fill that gap
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
- …
