Bionic Limbs: Clinical Reality and Academic Promises
Three recent articles in Science Translational Medicine (Tan et al. and Ortiz-Catalan et al., this issue; Raspopovic et al., 5 Feb 2014 issue, 222ra19) present neuroprosthetic systems in which sensory information is delivered through direct nerve stimulation while controlling an action of the prosthesis-in all three cases, arm and hand movement. We discuss such sensory-motor integration and other key issues in prosthetic reconstruction, with an emphasis on the gap existing between clinically available systems and more advanced, custom-designed academic systems. In the near future, osseointegration, implanted muscle, and nerve electrodes for decoding and stimulation may be components of prosthetic systems for clinical use, available to a large patient population
Context-Dependent Upper Limb Prosthesis Control for Natural and Robust Use
Pattern recognition and regression methods applied to the surface EMG have been used for estimating the user intended motor tasks across multiple degrees of freedom (DOF), for prosthetic control. While these methods are effective in several conditions, they are still characterized by some shortcomings. In this study we propose a methodology that combines these two approaches for mutually alleviating their limitations. This resulted in a control method capable of context-dependent movement estimation that switched automatically between sequential (one DOF at a time) or simultaneous (multiple DOF) prosthesis control, based on an online estimation of signal dimensionality. The proposed method was evaluated in scenarios close to real-life situations, with the control of a physical prosthesis in applied tasks of varying difficulties. Test prostheses were individually manufactured for both able-bodied and transradial amputee subjects. With these prostheses, two amputees performed the Southampton Hand Assessment Procedure test with scores of 58 and 71 points. The five able-bodied individuals performed standardized tests, such as the box&block and clothes pin test, reducing the completion times by up to 30%, with respect to using a state-of-the-art pure sequential control algorithm. Apart from facilitating fast simultaneous movements, the proposed control scheme was also more intuitive to use, since human movements are predominated by simultaneous activations across joints. The proposed method thus represents a significant step towards intelligent, intuitive and natural control of upper limb prostheses
The extraction of neural information from the surface EMG for the control of upper-limb prostheses
Despite not recording directly from neural cells, the surface electromyogram (EMG) signal contains information on the neural drive to muscles, i.e., the spike trains of motor neurons. Using this property, myoelectric control consists of the recording of EMG signals for extracting control signals to command external devices, such as hand prostheses. In commercial control systems, the intensity of muscle activity is extracted from the EMG and used for single degrees of freedom activation (direct control). Over the past 60 years, academic research has progressed to more sophisticated approaches but, surprisingly, none of these academic achievements has been implemented in commercial systems so far. We provide an overview of both commercial and academic myoelectric control systems and we analyze their performance with respect to the characteristics of the ideal myocontroller. Classic and relatively novel academic methods are described, including techniques for simultaneous and proportional control of multiple degrees of freedom and the use of individual motor neuron spike trains for direct control. The conclusion is that the gap between industry and academia is due to the relatively small functional improvement in daily situations that academic systems offer, despite the promising laboratory results, at the expense of a substantial reduction in robustness. None of the systems so far proposed in the literature fulfills all the important criteria needed for widespread acceptance by the patients, i.e. intuitive, closed-loop, adaptive, and robust real-time ( 200 ms delay) control, minimal number of recording electrodes with low sensitivity to repositioning, minimal training, limited complexity and low consumption. Nonetheless, in recent years, important efforts have been invested in matching these criteria, with relevant steps forwards
Game-Based Rehabilitation for Myoelectric Prosthesis Control
Background: A high number of upper extremity myoelectric prosthesis users abandon their devices due to difficulties in prosthesis control and lack of motivation to train in absence of a physiotherapist. Virtual training systems, in the form of video games, provide patients with an entertaining and intuitive method for improved muscle coordination and improved overall control. Complementary to established rehabilitation protocols, it is highly beneficial for this virtual training process to start even before receiving the final prosthesis, and to be continued at home for as long as needed.
Objective: The aim of this study is to evaluate (1) the short-term effects of a commercially available electromyographic (EMG) system on controllability after a simple video game-based rehabilitation protocol, and (2) different input methods, control mechanisms, and games.
Methods: Eleven able-bodied participants with no prior experience in EMG control took part in this study. Participants were asked to perform a surface EMG test evaluating their provisional maximum muscle contraction, fine accuracy and isolation of electrode activation, and endurance control over at least 300 seconds. These assessments were carried out (1) in a Pregaming session before interacting with three EMG-controlled computer games, (2) in a Postgaming session after playing the games, and (3) in a Follow-Up session two days after the gaming protocol to evaluate short-term retention rate. After each game, participants were given a user evaluation survey for the assessment of the games and their input mechanisms. Participants also received a questionnaire regarding their intrinsic motivation (Intrinsic Motivation Inventory) at the end of the last game.
Results: Results showed a significant improvement in fine accuracy electrode activation (P<.01), electrode separation (P=.02), and endurance control (P<.01) from Pregaming EMG assessments to the Follow-Up measurement. The deviation around the EMG goal value diminished and the opposing electrode was activated less frequently. Participants had the most fun playing the games when collecting items and facing challenging game play.
Conclusions: Most upper limb amputees use a 2-channel myoelectric prosthesis control. This study demonstrates that this control can be effectively trained by employing a video game-based rehabilitation protocol.(VLID)486422
Bionic reconstruction to restore hand function after brachial plexus injury: a case series of three patients
Background Brachial plexus injuries can permanently impair hand function, yet present surgical reconstruction provides only poor results. Here, we present for the first time bionic reconstruction; a combined technique of selective nerve and muscle transfers, elective amputation, and prosthetic rehabilitation to regain hand function. Methods Between April 2011, and May 2014, three patients with global brachial plexus injury including lower root avulsions underwent bionic reconstruction. Treatment occurred in two stages; first, to identify and create useful electromyographic signals for prosthetic control, and second, to amputate the hand and replace it with a mechatronic prosthesis. Before amputation, the patients had a specifically tailored rehabilitation programme to enhance electromyographic signals and cognitive control of the prosthesis. Final prosthetic fitting was applied as early as 6 weeks after amputation. Findings Bionic reconstruction successfully enabled prosthetic hand use in all three patients. After 3 months, mean Action Research Arm Test score increased from 5.3 (SD 4.73) to 30.7 (14.0). Mean Southampton Hand Assessment Procedure score improved from 9.3 (SD 1.5) to 65.3 (SD 19.4). Mean Disabilities of Arm, Shoulder and Hand score improved from 46.5 (SD 18.7) to 11.7 (SD 8.42). Interpretation For patients with global brachial plexus injury with lower root avulsions, who have no alternative treatment, bionic reconstruction offers a means to restore hand function
Targeted Muscle Reinnervation and Osseointegration for Pain Relief and Prosthetic Arm Control in a Woman with Bilateral Proximal Upper Limb Amputation
Background: Bilateral proximal upper limb loss is a dramatic life-changing event. Replacement of the lost function with prosthetic arms, including multiple mechatronic joints, has remained a challenge from the control, comfort, and pain management perspectives. Targeted muscle reinnervation (TMR) is a peripheral nerve surgical procedure proposed to improve the intuitive control of the prosthetic arm and for neuroma and phantom pain management. Moreover, osseointegrated percutaneous implants (OPIs) allow for direct skeletal attachment of the prosthetic arm, ensuring freedom of movement to the patient's residual articulations. Case Description: We have reported the first combined application of TMR and an OPI to treat a 24-year-old woman with a bilateral amputation at the shoulder level on the right side and at the very proximal transhumeral level on the left side. TMR was performed bilaterally in a single day, accounting for the peculiar patient's anatomy, as preparatory stage to placement of the OPI, and considering the future availability of implantable electromyographic sensors. The 2 OPI surgeries on the left side were completed after 8.5 months, and prosthetic treatment was completed 17 months after TMR. Conclusions: The use of TMR resolved the phantom pain bilaterally and the right-side neuroma pain. It had also substantially reduced the left side neuroma pain. The actual prosthetic control result was intuitive, although partially different from expectations. At 2 years after TMR, the patient reported improvement in essential activities of daily living, with a remarkable preference for the OPI prosthesis. Only 1 suspected case of superficial infection was noted, which had resolved. Overall, this combined treatment required a highly competent multidisciplinary team and exceptional commitment by the patient and her family
Translating research on myoelectric control into clinics – are the performance assessment methods adequate?
Missing an upper limb dramatically impairs daily-life activities. Efforts in overcoming the issues arising from this disability have been made in both academia and industry, although their clinical outcome is still limited. Translation of prosthetic research into clinics has been challenging because of the difficulties in meeting the necessary requirements of the market. In this perspective article, we suggest that one relevant factor determining the relatively small clinical impact of myocontrol algorithms for upper limb prostheses is the limit of commonly used laboratory performance metrics. The laboratory conditions, in which the majority of the solutions are being evaluated, fail to sufficiently replicate real-life challenges. We qualitatively support this argument with representative data from seven transradial amputees. Their ability to control a myoelectric prosthesis was tested by measuring the accuracy of offline EMG signal classification, as a typical laboratory performance metrics, as well as by clinical scores when performing standard tests of daily living. Despite all subjects reaching relatively high classification accuracy offline, their clinical scores varied greatly and were not strongly predicted by classification accuracy. We therefore support the suggestion to test myocontrol systems using clinical tests on amputees, fully fitted with sockets and prostheses highly resembling the systems they would use in daily living, as evaluation benchmark. Agreement on this level of testing for systems developed in research laboratories would facilitate clinically relevant progresses in this field
Functional outcome scores with standard myoelectric prostheses in below-elbow amputees
OBJECTIVE: To report normative outcome data of prosthetic hand function in below elbow amputees using four different objective measurements closely related to activities of daily living (ADL). DESIGN: Seventeen patients who underwent prosthetic fitting after unilateral below-elbow amputation were enrolled in this study. Global upper extremity function was evaluated using the Action Research Arm Test (ARAT), Southampton Hand Assessment Procedure (SHAP), the Clothespin-Relocation Test (CPRT) and the Box and Block Test (BBT), which monitor hand and extremity function. RESULTS: The patients achieved a mean ARAT score of 35.06 ± 4.42 of 57. The average SHAP score was 65.12 ± 13.95 points. The mean time for the CPRT was 22.57 ± 7.50 seconds and the mean score in the BBT was 20.90 ± 5.74. CONCLUSIONS: In the current economic situation of health care systems, demonstrating the effectiveness and necessity of rehabilitation interventions is of major importance. This study reports outcome data of below-elbow amputees and provides a useful guide for expected prosthetic user performance
- …