1,720,985 research outputs found
Acupuncture needling sensation: the neural correlates of deqi using fMRI
The needling sensation of deqi is considered by most acupuncturists to be an important component of acupuncture, yet neuroimaging research that investigates this needle sensation has been limited. In this study we have investigated the effect of deqi and acute pain needling sensations upon brain fMRI blood oxygen level-dependent (BOLD) signals. Seventeen right-handed participants who received acupuncture at the right LI-4 (Hegu) acupoint were imaged in a 3T MRI scanner. fMRI datasets were classified, on the basis of psychophysical participants' reports of needling scores, into those that were associated with predominantly deqi sensations versus those with predominantly acute pain sensations. Brain areas showing changes in BOLD signal increases (activations) and decreases (deactivations) were identified. Differences were demonstrated in the pattern of activations and deactivations between groupings of scans associated with deqi versus pain sensations. For the deqi grouping, significant deactivations occurred, whereas significant activations did not. In contrast, the predominantly acute pain grouping was associated with a mixture of activations and deactivations. For the comparison between the predominately deqi sensation grouping and the acute pain sensation grouping (deqi>pain contrast), only negative Z value voxels resulted (mainly from deactivations in the deqi grouping and activations in the pain grouping) in the limbic/sub-cortical structures and the cerebellum regions of interest. Our results show the importance of collecting and accounting for needle sensation data in neuroimaging studies of acupunctur
Brain imaging of acupuncture: comparing superficial with deep needling
The difference between superficial and deep needling at acupuncture points has yet to be mapped with functional magnetic resonance imaging (fMRI). Using a 3 T MRI, echo planar imaging data were acquired for 17 right-handed healthy volunteer participants. Two fMRI scans of acupuncture needling were taken in random order in a block design, one for superficial and one for deep needling on the right hand at the acupuncture point LI-4 (Hegu), with the participant blind to the order. For both scans needle stimulation was used. Brain image analysis tools were used to explore within-group and between-group differences in the blood oxygen level dependent (BOLD) responses. The study demonstrated marked similarities in BOLD signal responses between superficial and deep needling, with no significant differences in either activations (increases in BOLD signal) or deactivations (decreases in BOLD signal) above the voxel Z score of 2.3 with corrected cluster significance of P = 0.05. For both types of needling, deactivations predominatid over activations. These fMRI data suggest that acupuncture needle stimulation at two different depths of needling, superficial and deep, do not elicit significantly different BOLD responses. This data is consistent with the equivalent therapeutic outcomes that are claimed by proponents of Japanese and Chinese styles of acupuncture that utilise superficial and deep needling, respectively
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Development and applications of a smartphone-based mobile electroencephalography (EEG) system
Electroencephalography (EEG) is a clinical and research technique used to non-invasively acquire brain activity. EEG is performed using static systems in specialist laboratories where participant mobility is constrained. It is desirable to have EEG systems which enable acquisition of brain activity outside such settings. Mobile systems seek to reduce the constraining factors of EEG device and participant mobility to enable recordings in various environments but have had limited success due to various factors including low system specification. The main aim of this thesis was to design, build, test and validate a novel smartphone-based mobile EEG system.A literature review found that the term ‘mobile EEG’ has an ambiguous meaning as researchers have used it to describe many differing degrees of participant and device mobility. A novel categorisation of mobile EEG (CoME) scheme was derived from thirty published EEG studies which defined scores for participant and device mobilities, and system specifications. The CoME scheme was subsequently applied to generate a specification for the proposed mobile EEG system which had 24 channels, sampled at 24 bit at a rate of 250 Hz. Unique aspects of the EEG system were the introduction of a smartphone into the specification, along with the use of Wi-Fi for communications. The smartphone’s processing power was used to remotely control the EEG device so as to enable EEG data capture and storage as well as electrode impedance checking via the app. This was achieved by using the Unity game engine to code an app which provided the flexibility for future development possibilities with its multi-platform support.The prototype smartphone-based waist-mounted mobile EEG system (termed ‘io:bio’) was validated against a commercial FDA clinically approved mobile system (Micromed). The power spectral frequency, amplitude and area of alpha frequency waves were determined in participants with their eyes closed in various postures: lying, sitting, standing and standing with arms raised. Since a correlation analysis to compare two systems has interpretability problems, Bland and Altman plots were utilised with a priori justified limits of agreement to statistically assess the agreement between the two EEG systems. Overall, the results found similar agreements between the io:bio and Micromed systems indicating that the systems could be used interchangeably. Utilising the io:bio and Micromed systems in a walking configuration, led to contamination of EEG channels with artifacts thought to arise from movement and muscle-related sources, and electrode displacement.To enable an event related potential (ERP) capability of the EEG system, additional coding of the smartphone app was undertaken to provide stimulus delivery and associated data marking. Using the waist-mounted io:bio system, an auditory oddball paradigm was also coded into the app, and delivery of auditory tones (standard and deviant) to the participant (sitting posture) achieved via headphones connected to the smartphone. N100, N200 and P300 ERP components were recorded in participants sitting, and larger amplitudes were found for the deviant tones compared to the standard ones. In addition, when the paradigm was tested in individual participants during walking, movement-related artifacts impacted negatively upon the quality of the ERP components, although components were discernible in the grand mean ERP.The io:bio system was redesigned into a head-mounted configuration in an attempt to reduce EEG artifacts during participant walking. The initial approach taken to redesign the system involved using electronic components populated onto a flexible PCB proved to be non-robust. Instead, the rigid PCB form of the circuitry was taken from the io:bio waist-mounted system and placed onto the rear head section of the electrode cap via a bespoke cradle. Using this head-mounted system, in a preliminary auditory oddball paradigm study, ERP responses were obtained in participants whilst walking. Initial results indicate that artifacts are reduced in this head-mounted configuration, and N100, N200 and P300 components are clearly identifiable in some channels
Development and applications of a smartphone-based mobile electroencephalography (EEG) system
Electroencephalography (EEG) is a clinical and research technique used to non-invasively acquire brain activity. EEG is performed using static systems in specialist laboratories where participant mobility is constrained. It is desirable to have EEG systems which enable acquisition of brain activity outside such settings. Mobile systems seek to reduce the constraining factors of EEG device and participant mobility to enable recordings in various environments but have had limited success due to various factors including low system specification. The main aim of this thesis was to design, build, test and validate a novel smartphone-based mobile EEG system.A literature review found that the term ‘mobile EEG’ has an ambiguous meaning as researchers have used it to describe many differing degrees of participant and device mobility. A novel categorisation of mobile EEG (CoME) scheme was derived from thirty published EEG studies which defined scores for participant and device mobilities, and system specifications. The CoME scheme was subsequently applied to generate a specification for the proposed mobile EEG system which had 24 channels, sampled at 24 bit at a rate of 250 Hz. Unique aspects of the EEG system were the introduction of a smartphone into the specification, along with the use of Wi-Fi for communications. The smartphone’s processing power was used to remotely control the EEG device so as to enable EEG data capture and storage as well as electrode impedance checking via the app. This was achieved by using the Unity game engine to code an app which provided the flexibility for future development possibilities with its multi-platform support.The prototype smartphone-based waist-mounted mobile EEG system (termed ‘io:bio’) was validated against a commercial FDA clinically approved mobile system (Micromed). The power spectral frequency, amplitude and area of alpha frequency waves were determined in participants with their eyes closed in various postures: lying, sitting, standing and standing with arms raised. Since a correlation analysis to compare two systems has interpretability problems, Bland and Altman plots were utilised with a priori justified limits of agreement to statistically assess the agreement between the two EEG systems. Overall, the results found similar agreements between the io:bio and Micromed systems indicating that the systems could be used interchangeably. Utilising the io:bio and Micromed systems in a walking configuration, led to contamination of EEG channels with artifacts thought to arise from movement and muscle-related sources, and electrode displacement.To enable an event related potential (ERP) capability of the EEG system, additional coding of the smartphone app was undertaken to provide stimulus delivery and associated data marking. Using the waist-mounted io:bio system, an auditory oddball paradigm was also coded into the app, and delivery of auditory tones (standard and deviant) to the participant (sitting posture) achieved via headphones connected to the smartphone. N100, N200 and P300 ERP components were recorded in participants sitting, and larger amplitudes were found for the deviant tones compared to the standard ones. In addition, when the paradigm was tested in individual participants during walking, movement-related artifacts impacted negatively upon the quality of the ERP components, although components were discernible in the grand mean ERP.The io:bio system was redesigned into a head-mounted configuration in an attempt to reduce EEG artifacts during participant walking. The initial approach taken to redesign the system involved using electronic components populated onto a flexible PCB proved to be non-robust. Instead, the rigid PCB form of the circuitry was taken from the io:bio waist-mounted system and placed onto the rear head section of the electrode cap via a bespoke cradle. Using this head-mounted system, in a preliminary auditory oddball paradigm study, ERP responses were obtained in participants whilst walking. Initial results indicate that artifacts are reduced in this head-mounted configuration, and N100, N200 and P300 components are clearly identifiable in some channels
Development and applications of a smartphone-based mobile electroencephalography (EEG) system
Electroencephalography (EEG) is a clinical and research technique used to non-invasively acquire brain activity. EEG is performed using static systems in specialist laboratories where participant mobility is constrained. It is desirable to have EEG systems which enable acquisition of brain activity outside such settings. Mobile systems seek to reduce the constraining factors of EEG device and participant mobility to enable recordings in various environments but have had limited success due to various factors including low system specification. The main aim of this thesis was to design, build, test and validate a novel smartphone-based mobile EEG system.A literature review found that the term ‘mobile EEG’ has an ambiguous meaning as researchers have used it to describe many differing degrees of participant and device mobility. A novel categorisation of mobile EEG (CoME) scheme was derived from thirty published EEG studies which defined scores for participant and device mobilities, and system specifications. The CoME scheme was subsequently applied to generate a specification for the proposed mobile EEG system which had 24 channels, sampled at 24 bit at a rate of 250 Hz. Unique aspects of the EEG system were the introduction of a smartphone into the specification, along with the use of Wi-Fi for communications. The smartphone’s processing power was used to remotely control the EEG device so as to enable EEG data capture and storage as well as electrode impedance checking via the app. This was achieved by using the Unity game engine to code an app which provided the flexibility for future development possibilities with its multi-platform support.The prototype smartphone-based waist-mounted mobile EEG system (termed ‘io:bio’) was validated against a commercial FDA clinically approved mobile system (Micromed). The power spectral frequency, amplitude and area of alpha frequency waves were determined in participants with their eyes closed in various postures: lying, sitting, standing and standing with arms raised. Since a correlation analysis to compare two systems has interpretability problems, Bland and Altman plots were utilised with a priori justified limits of agreement to statistically assess the agreement between the two EEG systems. Overall, the results found similar agreements between the io:bio and Micromed systems indicating that the systems could be used interchangeably. Utilising the io:bio and Micromed systems in a walking configuration, led to contamination of EEG channels with artifacts thought to arise from movement and muscle-related sources, and electrode displacement.To enable an event related potential (ERP) capability of the EEG system, additional coding of the smartphone app was undertaken to provide stimulus delivery and associated data marking. Using the waist-mounted io:bio system, an auditory oddball paradigm was also coded into the app, and delivery of auditory tones (standard and deviant) to the participant (sitting posture) achieved via headphones connected to the smartphone. N100, N200 and P300 ERP components were recorded in participants sitting, and larger amplitudes were found for the deviant tones compared to the standard ones. In addition, when the paradigm was tested in individual participants during walking, movement-related artifacts impacted negatively upon the quality of the ERP components, although components were discernible in the grand mean ERP.The io:bio system was redesigned into a head-mounted configuration in an attempt to reduce EEG artifacts during participant walking. The initial approach taken to redesign the system involved using electronic components populated onto a flexible PCB proved to be non-robust. Instead, the rigid PCB form of the circuitry was taken from the io:bio waist-mounted system and placed onto the rear head section of the electrode cap via a bespoke cradle. Using this head-mounted system, in a preliminary auditory oddball paradigm study, ERP responses were obtained in participants whilst walking. Initial results indicate that artifacts are reduced in this head-mounted configuration, and N100, N200 and P300 components are clearly identifiable in some channels
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
- …
