1,721,003 research outputs found
Cause ed incidenza di revisione chirurgica dei dispositivi impiantabili: 4 anni di esperienza di un unico centro.
Closed-loop cardiac pacing vs. conventional dual-chamber pacing with specialized sensing and pacing algorithms for syncope prevention in patients with refractory vasovagal syncope: results of a long-term follow-up
AimsClosed-loop stimulation (CLS) pacing has shown greater efficacy in preventing the recurrence of vasovagal syncope (VVS) in patients with a cardioinhibitory response to head-up tilt test (HUTT) compared with conventional pacing. Moreover, there is no conclusive evidence to support the superiority of CLS over the conventional algorithms for syncope prevention. This study retrospectively evaluated the effectiveness of CLS pacing compared with dual-chamber pacing with conventional specialized sensing and pacing algorithms for syncope prevention in the prevention of syncope recurrence in patients with refractory VVS and a cardioinhibitory response to HUTT during a long-term follow-up.Methods and resultsForty-one patients (44 male, 53 ± 16 years) with recurrent, refractory VVS (26 with trauma) and a cardioinhibitory response to HUTT who had undergone pacemaker implantation were included in the analysis. Twenty-five patients received a dual-chamber CLS pacemaker (CLS group) and 16 patients received a dual-chamber pacemaker with conventional algorithms for syncope prevention (conventional pacing group): 9 patients with Medtronic rate drop response algorithm and 7 patients with Guidant-Boston Scientific sudden brady response algorithm. During the follow-up (mean 4.4 ± 3.0 years, interquartile range 2.27.4 years) one patient (4) in the CLS group and six (38) in the conventional pacing group had syncope recurrences (P 0.016). The KaplanMeier actuarial estimate of first recurrence of syncope after 8 years was 4 in the CLS group and 40 in the conventional pacing group (P 0.010).ConclusionsThe results of this retrospective analysis show that, in order to prevent a recurrence of VVS in patients with a cardioinhibitory response to HUTT, dual-chamber CLS pacing was more effective than dual-chamber pacing with conventional algorithms for syncope prevention in preventing bradycardia-related syncope. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2012.2012 © Published on behalf of the European Society of Cardiology
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
Rate, causes, and impact on patient outcome of implantable device complications requiring surgical revision: large population survey from two centres in Italy.
AimsThe long-term impact of implantable device-related complications on the patient outcome has not been thoroughly evaluated. The aims of this retrospective, bi-centre study were to analyse the rate and nature of device-related complications requiring surgical revision in a large series of patients undergoing device implantation, elective generator replacement and pacing system upgrade and to systematically assess the impact of such complications on patient outcome and healthcare utilization.Methods and resultsData from 2671 consecutive procedures (1511 device implantations, 1034 elective generator replacements, and 126 pacing system upgrades) performed between January 2006 and March 2011 were retrospectively analysed. The outcome measures recorded were complication-related mortality, number of re-operations, need for complex surgical procedures, number of re-hospitalizations, and additional hospital treatment days. Over a median follow-up of 27 months, the overall rate of complications was 2.8% per procedure-year [9.5% in cardiac resynchronisation therapy (CRT) device implantation, 6.1% in pacing system upgrade, 3.5% in implantable cardioverter defibrillator implantation, 1.7% in pacemaker implantation, and 1.7% in generator replacement). The procedure with the highest risk of complications was CRT device implantation (odds ratio: 6.6; P < 0.001); these complications primarily involved coronary sinus lead dislodgement and device infection. Patients with complications had a significantly higher number of device-related hospitalizations (2.3 ± 0.6 vs. 1.0 ± 0.1; P < 0.001) and hospital treatment days (15.7 ± 25.1 vs. 3.6 ± 1.1; P < 0.001) than those without complications. Device infection was the complication with the greatest negative impact on patient outcome.ConclusionCardiac resynchronisation therapy implantation was the procedure with the highest risk of complications requiring surgical revision. Complications were associated with substantial clinical consequences and a significant increase in the number and length of hospitalizations
Ruolo del monitoraggio remoto nella gestione di pazienti con device sottoposto ad avviso di sicurezza
- …
