    Surgical Management of Complications after Dexamethasone Implant

    No full text
    To report surgical management of ocular complications occurred after dexamethasone (DEX) implant (Ozurdex®) injection. Methods. Retrospective interventional case series. Results. Different surgical procedures including viscoexpression to manage the migration of the implant into the anterior chamber, “phaco-rolling” technique for the intralenticular injection, and vitrectomy with implant removal for an acute endophthalmitis were performed. Successful management of different complications after DEX implant by using individualized surgical approaches was observed. Conclusions. Early and targeted surgical management is required in selected cases of ocular complications after DEX implant. The implant removal was needed to preserve ocular anatomy and function

    25-Gauge Vitrectomy in Open Eye Injury with Retained Foreign Body

    No full text
    Purpose. Ocular trauma with retained foreign body is an important cause of visual impairment in working-age population. Clinical status impacts on the timing and planning of surgery. In the last year small gauge vitrectomy has become safer and more efficient, extending the range of pathologies successfully treated. Aims. To evaluate the safety and outcomes in patients with open eye injury with retained foreign body that underwent early 25-gauge vitrectomy. Methods. In this retrospective, noncomparative, interventional case series, we performed 25-gauge vitrectomy on 10 patients affected by open globe injuries with retained foreign body, over 3 years. We analyzed age, wound site, foreign body characteristics, ocular lesions correlated, relative afferent pupillary defect, visual acuity, and intraocular pressure. Follow-up evaluations were performed at 1, 3, and 6 months. According to the clinical status we performed other procedures to manage ocular correlated lesions. Results. The median age of patients was 37 years. The foreign body median size was 3.5 mm (size range, 1 to 10 mm). 25-gauge vitrectomy was performed within 12 hours of trauma. Foreign body removal occurred via a clear corneal or scleral tunnel incision or linear pars plana scleral access. Visual acuity improved in all patients. Endophthalmitis was never reported. Only two cases reported postoperative ocular hypertension resolved within the follow-up. Retinal detachment recurred in one case only. Conclusions. 25-gauge vitrectomy could be considered as early approach to manage open globe injuries with a retained posterior segment foreign body in selected cases with good outcomes and low complication rate

    INVERTED INTERNAL LIMITING MEMBRANE-FLAP TECHNIQUE FOR OPTIC DISK PIT MACULOPATHY: MORPHOLOGIC AND FUNCTIONAL ANALYSIS

    No full text
    To analyze morphologic and functional changes after inverted internal limiting membrane-flap technique for optic disk pit maculopathy using optical coherence tomography, multifocal electroretinography, and microperimetry

    One-year outcomes of 27-gauge versus 25-gauge pars plana vitrectomy for uncomplicated rhegmatogenous retinal detachment repair

    No full text
    27-gauge (27G) and 25-gauge (25G) transconjunctival sutureless vitrectomy (TSV) were considered equal about safety, effectiveness and vitrectomy time for the treatment of rhegmatogenous retinal detachment (RRD), although larger and long-term comparative studies are needed to confirm previous knowledge. Furthermore, a combined comparison of time duration of surgery and vitreous removal was never performed. Our purpose was to compare the safety and efficacy of 27G versus 25G TSV for the treatment of uncomplicated RRD over a 1-year follow-up

    sj-tif-1-ejo-10.1177_11206721221089172 - Supplemental material for Live surgery outcomes in cataract surgery

    No full text
    Supplemental material, sj-tif-1-ejo-10.1177_11206721221089172 for Live surgery outcomes in cataract surgery by Pasquale Puzo, Francesco D’Oria, Aurelio Imburgia, Cosimo Incandela, Alessandra Sborgia, Eleonora B Marchegiani, Laura Rania, Alessandro Mularoni and Giovanni Alessio in European Journal of Ophthalmology</p

    One-handed rotational phacoemulsification technique

    No full text
    Introduction: We described a one-handed rotational phacoemulsification technique to decrease phaco time and power, and surgical stress on the cornea in eyes with different types of cataract. Methods: In this technique a single sutureless corneal incision was made without any side-port incision. After hydrodissection and hydrodelamination were performed, a phaco tip was positioned in contact with the nucleus beside the capsulorhexis edge. By using a peristaltic pump, phacoemulsification was started with high levels of vacuum to keep the probe tip on the edge of the lens and to ensure the rotation of the nucleus, and with low ultrasound energy. The torsional mode used required less occlusion time and volume of fluid. The inclination of the tip was modified to 45-degree, directing it toward the lens center. So the nucleus was aspirated from the periphery toward the center by a rotational movement. Results: The eye in the technical video had a NC4-NO4 cataract. The preoperative vision in this eye was 20/100 with no improvement with refraction. On postoperative day 1, visual acuity had improved to 20/20. We recorded low intraoperative parameters including ultrasound time (21.4 sec), phacoemulsification power (73%), balanced salt solution used (31 mL) and cumulative dissipated energy (7.27) at the conclusion of the case. After 1 month, Central Corneal Thickness changed from 504 μm to 516 μm, and Endothelial Cell Loss was 1.15%. Conclusion: This technique uses a single clear corneal incision, high vacuum and low ultrasound power to reduce the exposition to excessive surgical maneuvers, fluid turbulence and ultrasound energy

    How Reliable Is Pyramidal Wavefront-Based Sensor Aberrometry in Measuring the In Vivo Optical Behaviour of Multifocal IOLs?

    No full text
    Cataract or refractive lens surgery, along with the implantation of multifocal intraocular lenses (MF-IOL), enables a complete range of functional far, near and intermediate vision. Refractive, diffractive and extended depth of focus (EDoF) or combination of these principles represent the technology used to obtain this multifocality. Aberrometry makes it possible to study the aberrations induced by MF-IOLs. Among the different optical principles available to measure ocular aberrations, pyramidal wavefront-based sensor (PWS) aberrometry shows the highest resolution with MF-IOLs. Retinal image quality measured by a PWS aberrometer differed significantly according to the technology of the implanted lens. Monofocal and diffractive lenses showed the highest values of far-distance retinal image quality, followed by refractive and EDoF lenses; however, retinal image quality analysed in diffractive lenses appears to be more dependent on residual refractive error. Considering this limitation, PWS-aberrometry could be used to compare diffractive lenses. Nevertheless, further studies are needed to provide additional information about the clinical retinal image quality of MF-IOLs and to help surgeons in the important preoperative selection of IOLs

    Inverted internal limiting membrane-flap technique for large macular hole: a microperimetric study

    No full text
    Inverted Internal Limiting Membrane (ILM)-flap technique would seem to lead to higher closure rate and better visual acuity than traditional procedure with ILM peeling for the treatment of large macular hole (LMH). Visual acuity recovery does not reveal many other functional changes related to surgical approach. Our purpose was to evaluate macular function and morphology over a 1-year follow-up after inverted ILM-flap technique for LMH by using microperimetry in order to predict visual prognosis
    corecore