1,720,977 research outputs found

    Focal electroretinogram and microperimetry testing of photoreceptor‐retinal pigment epithelium function in intermediate age‐related macular degeneration

    Full text link
    Purpose: To compare the performance of focal electroretinogram (FERG) and fast mesopic microperimetry in evaluating macular function of intermediate age-related macular degeneration (iAMD) subjects with preserved visual acuity. Methods: Cross-sectional, observational study. Participants with drusen >125 μm and VA ≥80 ETDRS letters and age- and sex-comparable healthy subjects were consecutively enrolled in the study. Three photopic FERG recordings of the central 9° of the macula with luminance modulated stimuli flickering at 42.5 Hz and a fast mesopic microperimetry with a custom pattern of 3 central (CS) and 3 paracentral (pCS) stimuli at 1.2° and 6° from fixation were acquired. Results: Overall, 112 eyes of 77 participants (age 73.0 ± 7.1 years, 47 iAMD eyes) were analysed. Mean FERG amplitude, CS and pCS (all p < 0.05) were lower in the iAMD group. A significant association was observed between FERG amplitude and iAMD (OR 9.58, p < 0.001) in multiple logistic regression analysis. Z-scores of FERG were lower than microperimetry in iAMD (p = 0.002) but not for healthy participants. AUC of the ROC curve was greater for FERG than microperimetry (0.895 versus 0.644 and 0.675, both p < 0.05). Conclusion: Focal ERG objectively measures a cumulative response originating from the photoreceptor-RPE complex of the central 9° of the macula and demonstrated high accuracy in identifying decreased central macular function in iAMD patients with preserved visual acuity, performing better than fast mesopic microperimetry. Focal ERG should be considered a reliable technique for measuring retinal sensitivity of iAMD patients

    Off-Centered DMEK Grafts: Impact and Resolution

    Full text link
    Purpose: The aim of this study was to assess the outcomes of off-centered Descemet membrane endothelial keratoplasty (DMEK) grafts compared to descemetorhexis. Methods: This is a retrospective case series of DMEK procedures conducted between June 2022 and July 2023 with postoperative graft decentration, characterized by a gap between the graft and descemetorhexis edge. Results: Eight eyes of 8 patients met the inclusion criteria. The average gap between the descemetorhexis edge and DMEK graft was 911.2 mm (range 306–1468). The resulting focal peripheral edema overlying the gap resolved in all cases, with a median time of 3 months. Best-corrected visual acuity improved from 0.49 (60.26) logarithm of the minimum angle of resolution to 0.01 (60.02) logarithm of the minimum angle of resolution at 12 months (P = 0.003). Central corneal thickness decreased from 646.5 (6177.8) mm to 473.7 (629.6) mm at 12 months (P = 0.05). One eye, in the overlapped area of host–donor Descemet membranes, had small peripheral partial graft detachment less than one-third of graft surface area. No eyes required graft rebubbling. A larger descemetorhexis to DMEK gap showed a trend toward longer resolution times (P = 0.06). Focal edema in the inferonasal periphery took longer to recover compared with the nasal position (P = 0.01). Larger descemetorhexis to DMEK gaps did not significantly influence the longitudinal visual acuity trend (P = 0.75). Conclusions: Decentered DMEK, characterized by a gap between the graft and descemetorhexis edge, leads to focal stromal edema that diminishes over time, with no impact on final visual acuity

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
    corecore