Institute of Tropical Medicine Antwerp

Tropmed Central Antwerp
Not a member yet
    6320 research outputs found

    Malaria rapid diagnostic kits: quality of packaging, design and labelling of boxes and components and readability and accuracy of information inserts

    No full text
    BACKGROUND: The present study assessed malaria RDT kits for adequate and correct packaging, design and labelling of boxes and components. Information inserts were studied for readability and accuracy of information. METHODS: Criteria for packaging, design, labelling and information were compiled from Directive 98/79 of the European Community (EC), relevant World Health Organization (WHO) documents and studies on end-users' performance of RDTs. Typography and readability level (Flesch-Kincaid grade level) were assessed. RESULTS: Forty-two RDT kits from 22 manufacturers were assessed, 35 of which had evidence of good manufacturing practice according to available information (i.e. CE-label affixed or inclusion in the WHO list of ISO13485:2003 certified manufacturers). Shortcomings in devices were (i) insufficient place for writing sample identification (n = 40) and (ii) ambiguous labelling of the reading window (n = 6). Buffer vial labels were lacking essential information (n = 24) or were of poor quality (n = 16). Information inserts had elevated readability levels (median Flesch Kincaid grade 8.9, range 7.1 - 12.9) and user-unfriendly typography (median font size 8, range 5 - 10). Inadequacies included (i) no referral to biosafety (n = 18), (ii) critical differences between depicted and real devices (n = 8), (iii) figures with unrealistic colours (n = 4), (iv) incomplete information about RDT line interpretations (n = 31) and no data on test characteristics (n = 8). Other problems included (i) kit names that referred to Plasmodium vivax although targeting a pan-species Plasmodium antigen (n = 4), (ii) not stating the identity of the pan-species antigen (n = 2) and (iii) slight but numerous differences in names displayed on boxes, device packages and information inserts. Three CE labelled RDT kits produced outside the EC had no authorized representative affixed and the shape and relative dimensions of the CE symbol affixed did not comply with the Directive 98/79/EC. Overall, RDTs with evidence of GMP scored better compared to those without but inadequacies were observed in both groups. CONCLUSION: Overall, malaria RDTs showed shortcomings in quality of construction, design and labelling of boxes, device packages, devices and buffers. Information inserts were difficult to read and lacked relevant information

    Investigation of an outbreak of Taenia saginata cysts (cysticercus bovis) in dairy cattle from two farms

    No full text
    The paper describes the epidemiological investigation carried out on two dairy farms with cattle infected with Taenia saginata cysts. On the first affected farm it was estimated using Bayesian techniques that approximately 65% of 1400 mixed-age cattle were infected with Taenia saginata cysts. The investigation aimed to determine potential exposure pathways of cattle to Taenia saginata with a view to finding the human source of infection and to describe the epidemiology of the outbreak on the affected farms. In order to determine potential exposure pathways, investigation was centred on how feed or water could have been contaminated with eggs. The plausibility of pathways was determined by examining the spatial and temporal association between factors related to the pathway and the prevalence of infection in cattle strata. We describe the investigation carried out on affected farms

    Low CD4+ T cell counts among African HIV-1 infected subjects with group B KIR haplotypes in the absence of specific inhibitory KIR ligands

    No full text
    Natural killer (NK) cells are regulated by interactions between polymorphic killer immunoglobulin-like receptors (KIR) and human leukocyte antigens (HLA). Genotypic combinations of KIR3DS1/L1 and HLA Bw4-80I were previously shown to influence HIV-1 disease progression, however other KIR genes have not been well studied. In this study, we analyzed the influence of all activating and inhibitory KIR, in association with the known HLA inhibitory KIR ligands, on markers of disease progression in a West African population of therapy-naive HIV-1 infected subjects. We observed a significant association between carriage of a group B KIR haplotype and lower CD4+ T cell counts, with an additional effect for KIR3DS1 within the frame of this haplotype. In contrast, we found that individuals carrying genes for the inhibitory KIR ligands HLA-Bw4 as well as HLA-C1 showed significantly higher CD4+ T cell counts. These associations were independent from the viral load and from individual HIV-1 protective HLA alleles. Our data suggest that group B KIR haplotypes and lack of specific inhibitory KIR ligand genes, genotypes considered to favor NK cell activation, are predictive of HIV-1 disease progression

    Global health aid: raise more, spend better [letter]

    No full text

    The use of microbead-based spoligotyping for Mycobacterium tuberculosis complex to evaluate the quality of the conventional method : Providing guidelines for quality assurance when working on membranes

    No full text
    BACKGROUND: The classical spoligotyping technique, relying on membrane reverse line-blot hybridization of the spacers of the Mycobacterium tuberculosis CRISPR locus, is used world-wide (598 references in Pubmed on April 8th, 2011). However, until now no inter-laboratory quality control study had been undertaken to validate this technique. We analyzed the quality of membrane-based spoligotyping by comparing it to the recently introduced and highly robust microbead-based spoligotyping. Nine hundred and twenty-seven isolates were analyzed totaling 39,861 data points. Samples were received from 11 international laboratories with a worldwide distribution. METHODS: The high-throughput microbead- based Spoligotyping was performed on CTAB and thermolyzate DNA extracted from isolated Mycobacterium tuberculosis complex (MTC) strains coming from the genotyping participating centers. Information regarding how the classical Spoligotyping method was performed by center was available. Genotype discriminatory analyses were carried out by comparing the spoligotypes obtained by both methods. The non parametric U-Mann Whitney homogeneity test and the Spearman rank correlation tests were performed to validate the observed results. RESULTS: Seven out of the 11 laboratories (63 %), perfectly typed more than 90% of isolates, 3 scored between 80-90% and a single center was under 80% reaching 51% concordance only. However, this was mainly due to discordance in a single spacer, likely having a non-functional probe on the membrane used. The centers using thermolyzate DNA performed as well as centers using the more extended CTAB extraction procedure. Few centers shared the same problematic spacers and these problematic spacers were scattered over the whole CRISPR locus (Mostly spacers 15, 14, 18, 37, 39, 40). CONCLUSIONS: We confirm that classical spoligotyping is a robust method with generally a high reliability in most centers. The applied DNA extraction procedure (CTAB or thermolyzate) did not affect the results in this study. However performance was center-dependent, suggesting that training is a key component in quality assurance of spoligotyping. Overall, no particular spacer yielded a higher degree of deviating results, suggesting that errors occur randomly either in the process of re-using membranes, or during the reading of the results and transferring of data from the film to a digital file. Last, the performance of the microbead-based method was excellent as previously shown by Cowan et al. (J. Clin. Microbiol. 2004) and Zhang et al. (J. Med. Microbiol. 2009), and demonstrated the proper detection of spacer 15 that is known to occasionally give weak signals in the classical spoligotyping

    Seroprevalence of transfusion-transmissible infections and evaluation of the pre-donation screening performance at the Provincial Hospital of Tete, Mozambique

    No full text
    BACKGROUND: The World Health Organization recommends universal and quality-controlled screening of blood donations for the major transfusion-transmissible infections (TTIs): human immunodeficiency virus (HIV), hepatitis B virus (HBV), hepatitis C virus (HCV) and syphilis. The study objectives were to determine the seroprevalence of these TTIs among blood donors at the Provincial Hospital of Tete, Mozambique, and to assess the local pre-donation screening performance. METHODS: All consenting voluntary and replacement candidate blood donors were consecutively included from February to May 2009. Sera of all candidates, independent of deferral by questionnaire, were submitted to screening with quality-assured rapid or simple assays for HIV, HBV surface antigen (HBsAg), HCV and syphilis. Assays locally used by the blood bank for HBV and syphilis screening were run in parallel to quality-assured external assays supplied during the study, and all discordant samples were submitted to confirmation testing in reference laboratories in Mozambique and Belgium. RESULTS: Of 750 consenting candidates (50.5% of voluntary donors), 71 (9.5%) were deferred by the questionnaire, including 38 specifically because of risk behavior for TTI. Of the 679 non-deferred candidates, 127 (18.7%) had serological confirmation of at least one TTI, with a lower prevalence in voluntary than in replacement donors (15.2% versus 22.4%, p=0.016). Seroprevalence of HIV, HBsAg and syphilis infections was 8.5%, 10.6 % and 1.2%. No confirmed HCV infection was found. Seroprevalence of TTIs was similar in the 38 candidates deferred for TTI risk as in the non-deferred group, except for HBsAg (26.3 % versus 10.6 %; p=0.005). The local assays used for HBV and syphilis had sensitivities of 98.4% and 100% and specificities of 80.4% and 98.8% respectively. This resulted in the rejection of 110 of the 679 blood donations (16.2%) because of false positive results. CONCLUSIONS: The seroprevalence of TTIs after questionnaire screening is high in Tete, Mozambique, but HCV infection does not appear as a major issue. The questionnaire did not exclude effectively HIV-infected donor candidates, while the locally used assays led to unnecessary rejection of many safe donations. A contextualized questionnaire and consistent use of quality-assured assays would considerably improve the current screening procedure for blood donation

    Development and validation of systems for rational use of viral load testing in adults receiving first-line ART in sub-Saharan Africa

    No full text
    BACKGROUND:: World Health Organization (WHO) immunological and clinical criteria for monitoring first-line antiretroviral treatment (ART) offer low accuracy for predicting viral failure. Targeting viral load assays to those at high risk has been recommended and a system to do this has been developed in Cambodia. Systems for use in Sub-Saharan African populations were evaluated. METHODS:: A new Ugandan based scoring system for targeting viral load assays was developed from data from the first 4 years of a Ugandan cohort (N = 559) receiving first-line ART. The accuracy of this, the Cambodian system and the WHO criteria to predict viral failure, through targeting viral load assays, were compared in a separate population of 496 Ugandans. RESULTS:: The new Ugandan scoring system included CD4 count, mean cell volume, adherence, and HIV associated clinical events as predictors of viral failure. In the validation population, the Ugandan system undertook viral load assays in 61 (12.3%) cases offering 20.5% sensitivity and 100% positive predictive value (PPV) to predict viral failure. The Cambodian system undertook viral load assays in 33 (6.7%) cases producing 23.1% sensitivity and 90.0% PPV. WHO criteria recommended viral load assays in 72 (14.5%) cases offering 30.8% sensitivity and 100% PPV. CONCLUSIONS:: Locally developed algorithms based on clinical and immunological criteria may offer little additional accuracy over WHO criteria for targeting viral load assays. Where possible, confirming viral load before switching therapy is recommended. Scoring systems are more flexible than WHO criteria in allowing ART providers to choose the proportion of the population that undergo targeted viral load testing

    A review of trends in the distribution of vector-borne diseases: is international trade contributing to their spread?

    No full text
    It is difficult to determine the part that international trade has played in the expansion of vector-borne diseases, because of the multitude of factors that affect the transformation of habitats and the interfaces between vectors and hosts. The introduction of pathogens through trade in live animals or products of animal origin, as well as the arrival of arthropod vectors, is probably quite frequent but the establishment of an efficient transmission system that develops into a disease outbreak remains the exception. In this paper, based on well-documented examples, the authors review the ecological and epidemiological characteristics of vector-borne diseases that may have been affected in their spread and change of distribution by international trade. In addition, they provide a detailed analysis of the risks associated with specific trade routes and recent expansions of vector populations. Finally, the authors highlight the importance, as well as the challenges, of preventive surveillance and regulation. The need for improved monitoring of vector populations and a readiness to face unpredictable epidemiological events are also emphasised, since this will require rapid reaction, not least in the regulatory context

    Trypanosoma lewisi or T. lewisi-like infection in a 37-day-old Indian infant

    No full text
    Trypanosomes were observed in the peripheral blood smear of a 37-day-old Indian infant admitted off feeds, with fever and convulsions. Trypanosoma (Herpetosoma) lewisi was identified in the blood. The species identification was confirmed by morphometry, polymerase chain reaction, and sequencing. Human infection with this organism is rare. Only seven cases of this infection have been reported previously in humans. The cases reported are reviewed to develop a composite picture of this disease

    Assessment of the knowledge of graphical symbols labelled on malaria rapid diagnostic tests in four international settings

    No full text
    BACKGROUND: Graphical symbols on in vitro diagnostics (IVD symbols) replace the need for text in different languages and are used on malaria rapid diagnostic tests (RDTs) marketed worldwide. The present study assessed the comprehension of IVD symbols labelled on malaria RDT kits among laboratory staff in four different countries. METHODS: Participants (n = 293) in Belgium (n = 96), the Democratic Republic of the Congo (DRC, n = 87), Cambodia (n = 59) and Cuba (n = 51) were presented with an anonymous questionnaire with IVD symbols extracted from ISO 15223 and EN 980 presented as stand-alone symbols (n = 18) and in context (affixed on RDT packages, n = 16). Responses were open-ended and scored for correctness by local professionals. RESULTS: Presented as stand-alone, three and five IVD symbols were correctly scored for comprehension by 67% and 50% of participants; when contextually presented, five and seven symbols reached the 67% and 50% correct score respectively. 'Batch code' scored best (correctly scored by 71.3% of participants when presented as stand-alone), 'Authorized representative in the European Community' scored worst (1.4% correct). Another six IVD symbols were scored correctly by less than 10% of participants: 'Do not reuse', 'In vitro diagnostic medical device', 'Sufficient for', 'Date of manufacture', 'Authorised representative in EC', and 'Do not use if package is damaged'. Participants in Belgium and Cuba both scored six symbols above the 67% criterion, participants from DRC and Cambodia scored only two and one symbols above this criterion. Low correct scores were observed for safety-related IVD symbols, such as for 'Biological Risk' (42.7%) and 'Do not reuse' (10.9%). CONCLUSION: Comprehension of IVD symbols on RDTs among laboratory staff in four international settings was unsatisfactory. Administrative and outreach procedures should be undertaken to assure their acquaintance by end-users

    14

    full texts

    6,320

    metadata records
    Updated in last 30 days.
    Tropmed Central Antwerp is based in Belgium
    Access Repository Dashboard
    Do you manage Open Research Online? Become a CORE Member to access insider analytics, issue reports and manage access to outputs from your repository in the CORE Repository Dashboard! 👇