Electrician
Not a member yet
543 research outputs found
Sort by
Design and Construction of Solar Home System (SHS) with Application of Automatic Transfer Switch (ATS) as a Source of Electrical Energy for Residential Homes
Sistem Kendali Kadar Air dan Monitor Suhu Pengering Lada Hitam Berbasis Jaringan Multi Sensor
Industri Agribisnis hasil perkebunan pasca panen, kadar air penting dalam menentukan kualitas biji lada hitam. Penelitian pengembangan ini menyajikan tentang sistem kendali kadar air dan memonitor suhu pengering lada hitam berbasis multi sensor. Sensor PT100RTD pengindera suhu, sensor THD-DD2-C pengindera suhu dan kelembaban dan PLC CP1H-XA40DR-A sebagai central processing unit terkait dengan sistem SCADA sebagai user interface. Perancangan bertujuan mengindera suhu dan kelembapan kadar air lada hitam. Selanjutnya tingkat kelembaban dan suhu dikondisikan kadar air lada hitam berada 11 % sd. 12%. Perancangan berhasil diinstal untuk memantau kadar air lada hitam. Dengan menerapkan sistem ini, perbedaan rata-rata kadar air 10.59% saat pratest dan 11,57% saat posttest mempunyai efisiensi selisih kehilangan berat lada hitam selama proses berkurang 0,98%. Sistem kendali yang dibangun memiliki tingkat keakuratan cukup tinggi dengan error 2,76 %. Operasi SCADA sebagai user interface yang dibangun memungkinkan pengguna untuk memonitoring secara real time
Homer pro Studi Kelayakan Sistem Hybrid PLTD-PLTS dan Analisis Sistem Tenaga (Load Flow) di Pulau Tabuan Provinsi Lampung
Pulau terpencil di Indonesia memenuhi kebutuhan energi listriknya menggunakan PLTD yang memiliki biaya operasional dan pemeliharaan tinggi. Penelitian ini bertujuan untuk mengetahui kelayakan sistem pembangkit hybrid baru yang dapat menurunkan biaya operasional dan biaya cost of electricity (COE) yang tinggi. Hasil penelitian dari segi ekonomi menunjukkan adanya penurunan biaya pokok penyedia listrik dari sistem pembangkit sebelumnya sebesar 6.940 Rp/kWh ke sistem pembangkit hybrid yang baru sebesar 4.343,36 Rp/kWh atau mengalami penurunan sebesar 19% dan dari segi teknis menunjukkan bahwa jaringan distribusi listrik yang telah tersedia tidak mengalami pembebanan listrik yang berlebihan dan tidak mengalami drop tegangan yang lebih dari 5% saat dilakukan simulasi penerapan sistem pembangkit listrik hybrid yang baru sehingga dapat dikatakan jaringan distribusi listrik masih sanggup dan drop tegangan masih dalam batas wajar. Nilai cost of electricity (COE) yang masih di atas nilai COE listrik yang telah ditetapkan oleh PLN yaitu sebesar 1.352 Rp/kWh sehingga sistem hybrid PLTD-PLTS ini belum mampu atau belum layak untuk memenuhi standar nilai COE listrik PLN.
Keywords: Homer pro, Hybrid Generation System, Cost of Electricity (COE), Isolated Power Grid, Load Flow
a Comprehensive and Inclusive Key Design for Smart Parking Solution Using the Three Validation Real Time Method
This study presents an innovative smart parking system known as SM Park, which utilizes the Three Validation Real-Time (3VR) method to provide accurate and efficient parking space monitoring. The system integrates multiple sensor technologies, including ultrasonic and Passive Infrared (PIR) sensors, along with computer vision, to detect the availability of parking slots in real-time. By leveraging the Internet of Things (IoT) and Artificial Intelligence (AI), SM Park enables users to reserve parking spaces in advance via its website, thus minimizing wait times and improving the overall efficiency of parking. The development process followed a prototype methodology, which allowed for rapid prototyping, feedback collection, and iterative design enhancements. The system's performance was evaluated through various stages, including literature review, system design, prototype development, and sensor integration. The system design eliminates the need for external devices such as RFID tags or mobile applications, creating a more inclusive parking solution. This paper outlines the design and architecture of the SM Park system, its technical components, and its potential for addressing key challenges in urban parking management, such as congestion, carbon emissions, and inefficient space utilization
Electric Power Monitoring System on Solar Panels with the Application of Internet of Things (IoT)
Analisa Pengaruh Jumlah Sudu dan Model Sudu Turbin Terhadap Daya Turbin Undershot Pembangkit Listrik Tenaga Mikro Hidro
Micro Hydro Power Plant is a small scale power plant that uses hydropower as its energy source. The power to drive the PLTMH turbine is in the form of water flow originating from irrigation canals and rivers. The undershot turbine is a type of water turbine that utilizes river flow or irrigation channels as the driving force for the undershot turbine. In this research, based on the problems used in undershot turbines in order to get maximum results, the researcher designed a PLTMH prototype by analyzing the effect of the number of blades and the turbine blade model on the power produced by the generator in the undershot turbine of a micro hydro power plant so that it would be known that the number of blades was 12 , 14, 18 and the triangular blade model which obtains better PLTMH output. In this study, the number of blades was 14 which was the best with a resulting voltage of 9.4 volts, a current of 0.96 amperes and a power of 9.02 watts
Implementasi Fuzzy Tahani Dalam Model Sistem Rekomendasi Pemilihan Produk Proyektor Android
Rancang Bangun Alat Penyiraman Otomatis Tanaman Stroberi dengan Sistem dan Pengendalian Dari Jarak Jauh Menggunakan Aplikasi Blynk
Kemajuan teknologi telah mengubah banyak sektor, termasuk pertanian. Internet of Things (IoT) adalah salah satu perkembangan terbaru yang memungkinkan alat-alat pertanian terhubung ke internet. Potensi komersial stroberi sebagai komoditas hortikultura menarik karena nilai ekonominya yang tinggi. Saat ini proses penyiraman tanaman stroberi masih dilakukan secara manual, sehingga membutuhkan waktu yang lama dan tenaga kerja manusia. Hal ini membuat proses penyiraman menjadi tidak efektif untuk menjaga kelengasan tanah dalam kondisi yang ideal. Oleh karena itu dibutuhkan alat penyiraman otomatis. Terdapat beberapa parameter yang diperhatikan dalam penyiraman otomatis, di antaranya kelengasan dan pH tanah. Penelitian ini merancang prototipe alat pemantau dan pengontrol kelengasan serta pH tanah berbasis IoT, dengan menggunakan sensor kelengasan dan pH tanah sebagai parameter utama serta dua buah pompa. Data dari sensor diproses oleh Mikrokontroler ESP32 dan ditampilkan pada platform Blynk. Kelengasan tanaman stroberi yang diinginkan diatas 80% dan rentang pH antara 6,5-7. Saat pengujian sensor, didapatkan tingkat akurasi yang dihasilkan oleh sensor kelengasan sebesar 85,99% dan sensor pH sebesar 99,82 %. Selain itu, terdapat jeda waktu sebesar 1.12 detik pada aplikasi Blynk saat melakukan kendali nyala atau mati pada relay
Proses Perbaikan Data ODP (Optical Distribution Point) Tidak Sama dan Rename ODP Menggunakan UIM Tools Untuk Meluruskan Service di PT. TELKOM WITEL KARAWANG
Kereta Rel Listrik (KRL) dalam operasionalnya disuplai tegangan 1500 VDC yang diperoleh dari 20 kV PLN kemudian diturunkan dengan sistem penyearah pada Gardu Traksi KRL. Penyearah yang prinsip kerjanya switching merupakan kategori beban non-linear dapat memproduksi harmonisa yang dapat menyebabkan penuruan kehandalan pada peralatan gardu traksi, selain itu kebutuhan daya reaktif yang berlebih dapat menghasilkan harmonisa. Metode yang digunakan dalam penelitian ini dengan mengambil data daya termasuk data beban dan kapasitas transformator pada gardu traksi, kemudian dilakukan simulasi untuk mendapatkan nilai harmonisa awal tanpa filter pasif. Hasil pengujian pertama tanpa menggunakan filter pasif pada transformator 20 kV/1,5kV menunjukkan nilai harmonisa sebesar 20,37% hasil tersebut masih sesuai standar, sedangkan harmonisa yang dibutuhkan adalah <5% (sesuai standar IEEE 519-2014) sehingga perlu dilakukan mitigasi perbaikan. Perbaikan dilakukan dengan menambahkan filter pasif high-pass pada bus transformator dan bus beban, hasil pengujian menggunakan filter pasif menunjukan penurunan nilai harmonisa menjadi 3,36%