Repository of the Institute of Nuclear Physics PAN
Not a member yet
    364 research outputs found

    Preliminary Study of Elemental and Radionuclides Composition in Sediment Samples from Dobczyce Water Reseivoir

    No full text
    Sediments play fundamental role in toxic compounds distribution in aquatic systems and in the evaluation of current state and course of changes taking place in environment. On the other hand physical, chemical, biochemical and geochemical processes that influence toxic compounds and elements fate in sediments are numerous and complex (for example: adsorption – desorption, oxidation – reduction, ion-exchange, biological activity). River and lake sediments constitute also very difficult analytical samples. Due to the above mentioned general statements only long term and as complex as possible research can lead to satisfactory answers to the question about drinking water quality for the city of Cracow. Therefore in this paper, introductory results concerning determination of concentration of chosen elements such as Al, P, K, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, NI, Cu, Zn and radionuclids natural ( 40K ) and artificial (137Cs) in the depth profile of sediment samples from the Dobczyce Reservoir are presented. For the best quality of experimental work several analytical techniques, were applied namely: Proton Induced X-ray Emission (PIXE), Rutherford Back-Scattering (RBS), Atomic Absorption Spectroscopy (AAS), gamma spectrometry, and x-ray diffraction

    Analysis of Tests of the CASTOR Calorimeter Prototype

    No full text

    Energy Evolution of the Total Cross Section - Significance of the HERA γp Measurements

    No full text

    Ewolucja nieliniowa w chromodynamice kwantowej i jej zastosowania do produkcji neutrin przy bardzo wysokich energiach

    No full text
    Praca dotyczy badań nad zjawiskiem saturacji partonowej w zderzeniach cząstek przy wysokich energiach. Zaobserwowane zostało zjawisko skalowania geometrycznego w przekroju czynnym na głębokonieelastyczne zderzenia elektronu z protonem. Skalowanie to może być interpretowane jako przejaw saturacji partonowej. Polega ono na zależności całkowitego przekroju czynnego od jednej zmiennej τ ≡ Q 2 /Q 2s (x) będącej stosunkiem wirtualności fotonu Q 2 do skali saturacji Q 2 s (x) zależnej potęgowo od x Bjorkena

    Monte Carlo Simulations of the Spectrometric n-Gamma Well Logging. Comparison of Simulations and Measurements for the SO-5-90 Logging Tool

    No full text
    The results of the Monte Carlo simulations (MCNP code) of the spectrometric neutron-gamma well logging (sNGL) are presented. The sNGL can be very useful for the precise lithology determination, what is especially important for oil and gas prospecting in shally–sand formations. Possibility of determination of the Si, Ca and Fe content in rocks by means of the analysis of gamma ray spectra induced by the captured neutrons is well known for 40 years at least [Larionov, 1969]. Preliminary sNGL experiments performed at the Polish Calibration Station in Zielona Góra, using a simple borehole spectrometer equipped with the isotopic Am-Be neutron source and the BGO detector, fully confirmed this possibility. MCNP simulations of the sNGL experiments have been done for the SO-5-90 neutron-gamma spectrometer and for the lithology models (standards) of the Calibration Station. The concentrations of H, Si, Ca and Fe in these models have been determined from the real and simulated experiments using the simulated (“MCNP”) and measured (“meas”) spectra of gamma-rays from neutron interactions with the rock nuclei. The H, Si and Ca concentrations obtained from the simulated experiment are well correlated with their reference values, known from the chemical (“chem”) analyses - regarded as true values. Squares of the correlation coefficients (R2) amount to 0.992, 0.988 and 0.984, respectively. For Fe, a lower R2 has occurred for the linear dependence FeMCNP(Fechem) than for Femeas(Fechem) amounting to 0.834 and 0.923 respectively. Although the established correlations between results of the real and simulated sNGL experiments show the high values of correlation coefficients, the noticeable improvement of these correlations is expected for the fully verified chemical composition of the Zielona Góra standards and for improved parameters of the n-gamma spectrometer. The usefulness of the MCNP code for modeling the spectrometric neutron-gamma logging tool responses is confirmed. The possibility of the fast and accurate computer simulations opens a new field for development of the spectrometric n-gamma logging. Especially the influence of such disturbing factors as borehole conditions, borehole and formation salinities or presence of the additional rock elements (like B, S, K, Gd ) must be precisely known when the quantitative determination of Si, Ca and Fe is required

    Nowe źródło jonów cyklotronu AIC-144

    No full text
    A new ion source for the AIC-144 isochronous cyclotron is presented. The source is of the PIG-type for production protons, deuterons and helions. It is most convinient as an “old” source f.ex. filament of the cathod is exchaanged only by pulling of a cathod’s holder. The source possess some new mechanisms for improving of exploitation

    Development of Kraków External Microbeam - Single Ion Hit Facility

    No full text
    The main purpose of building the microbeam setup for the external (i.e out-of-vacuum) measurements is single cell with single ions irradiation. The single-ion hit facility is based on the existing Kraków microbeam setup characterized by the spatial resolutions of about 3 μm. Present work introduces the setup and the measurement chamber that was developed, constructed and assembled in IFJ PAN. The passage of single ions from vacuum to atmosphere (where the cell dish is located) is registered using the channeltron detector installed inside the chamber. Channeltron registers secondary electrons emitted from CsI layer covering the Si3N4 exit window. The system of very precise diaphragms reduces the beam intensity down to a fluence of about 103 protons/sec. The beam blanking, correlated with single proton passage is provided by the fast, electrostatic deflecting system. The precise 3D table, installed outside the chamber, allows positioning the cell dish at a 200 μm distance from the exit window and change the targeted cell with a sub-micrometer precision within the dish. The paper shows results of the preliminary investigations aimed towards optimization of the most important issues: resolution of external microbeam, proton registration efficiency, efficiency of deflecting system and accuracy of single-proton-hit system

    Cyclotron Production, Separation and Quality Control of 73As

    No full text
    The isotope 73As has been produced on the AIC-144 cyclotron via the natGe(p,xn)73As nuclear reaction. The high purity germanium target of natural isotopic abundance was bombarded by the internal proton beam. The target was dissolved in aqua regia, and the As isotopes were separated on the Dowex-1 ion-exchange resin. The contaminant 74As was let to decay. Traces of stable germanium in the final product were determined spectrophotometrically and by the internal tracer method. The 69Ge tracer was produced on the same cyclotron in the Zn(α,xn)69Ge reactions. The isotope 69Ge as well as its contaminants 66Ga and 67Ga, produced in Zn(α,pxn)66,67Ga reactions, were separated from Zn by solvent extraction from 7M HCl. The resultant carrier-free 73As was of high radionuclide purity and did not contain detectable traces of the target material

    SCTHV VME Model 203 User's Manual

    No full text
    This manual describes the elements of the SCT High Voltage Power Supply – VME Model HV203, its operation and installation procedures

    Analiza materiałów biomedycznych wybranymi metodami spektroskopowymi

    No full text
    Rozwój analitycznych metod fizycznych wykorzystujących cząstki naładowane oraz promieniowanie synchrotronowe pozwolił na zastosowanie ich w wielu dziedzinach nauki, a w szczególności w biologii i medycynie. Zastosowanie tych metod umożliwia prowadzenie badań w mikro obszarach tkanek, a nawet w pojedynczych komórkach. Z końcem dwudziestego wieku nastąpił znaczny rozwój metod, dzięki którym można prowadzić jednoczesną analizę składu pierwiastkowego oraz stopnia utlenienia metali występujących w materiałach biologicznych na poziomie śladowym. Ciągła potrzeba prowadzenia prac badawczych z zakresu diagnostyki medycznej staje się inspiracją do rozwoju metod, za pomocą których będzie można odpowiedzieć na nurtujące środowisko medyczne pytania dotyczące: etiologii powstawania chorób, możliwości ich wczesnego diagnozowania, zapobiegania i leczenia. Aby móc udzielić odpowiedzi na wiele pytań z tego zakresu wciąż jeszcze muszą być prowadzone prace badawcze przez wiele środowisk naukowych współpracujących ze sobą. W pracach tych szczególne znaczenia przypada właśnie fizyce, która dysponuje specyficznymi metodami pozwalającymi na prowadzenie badań w mikro a nawet nano obszarach. Pierwiastki śladowe odgrywające ważną rolę w organizmie człowieka są częstym obiektem badań. Istotnym jest poznanie składu chemicznego oraz stężeń pierwiastków śladowych występujących w poszczególnych narządach, tkankach, i komórkach. Przedstawiona rozprawa habilitacyjna dotyczy badań materiałów biomedycznych pobranych od pacjentów ze schorzeniami układu moczowego. Badany materiał to: kamienie nerkowe, tkanki nerek i prostaty. Zaprezentowane wyniki pomiarowe dotyczą stosowania różnorodnych fizycznych metod analitycznych, do których można zaliczyć: PIXE (Proton Induced X-ray Emission), AAS (Atomic Absorptopn Spectroscopy), R(E)BS (Rutherford (Elastic) BackScattering), XRF (X-Ray Fluorescence), TRXRF (Total Reflection X-Ray Fluorescence), SRIXE (Synchrotron Radiation Induced X-ray Emission), FTIR (Fourier Transform InfraRed), oraz XANES (X-ray Absorption Near Edge Structure). Niektóre metody fizyczne stały się konkurencyjnymi do metod chemicznych z uwagi na możliwość prowadzenia badań i analiz materiałów biologicznych nie powodując ich destrukcji. Możliwość jednoczesnego pomiaru badanych związków i zachowania struktury tkanek stanowi główną zaletę wielu metod fizycznych i daje szereg możliwości przeprowadzania różnorodnych analiz na tym samym materiale badawczym. Ważnym aspektem tych możliwości jest wzajemne wspieranie rozwijających się metod diagnostycznych wynikami badań podstawowych jakie oferują te metody

    0

    full texts

    364

    metadata records
    Updated in last 30 days.
    Repository of the Institute of Nuclear Physics PAN
    Access Repository Dashboard
    Do you manage Open Research Online? Become a CORE Member to access insider analytics, issue reports and manage access to outputs from your repository in the CORE Repository Dashboard! 👇