Riga Technical University

Riga Technical University Repository
Not a member yet
    18420 research outputs found

    The Research of the Parameters Changes of the Grounding System

    No full text
    This scientific paper presents a survey of soil resistivity and how its value varies from geological and meteorological factors. Soil resistivity is not only a useful measurable that reflects subsurface structure, but also a basic parameter to the design of effective grounding and lightening prevention / protection system. The most significant variations occur from such parameters of soil resistivity as contamination, moisture content, chemical composition, porosity, conductivity, temperature, vertical thickness and divisions, etc. Knowledge of soil resistivity at the intended site provides a valuable insight into how the desired ground resistance value can be achieved and maintained over the life of the installation with the minimum cost and effort. The grounding of electrical installations is primarily concerned with safety; in particular, the prevention of electrical shock risks of human life. As such, a grounding system must be designed, tested and maintained to satisfy this primary aim

    Maksātnespējas procesa raksturojums Luksemburgā

    No full text
    Maksātnespēja paliek aizvien aktuāla, un varam būt droši, ka tā tas paliks vēl ilgu laiku. Katra uzņēmuma saimnieciskā darbība ir saistīta ar maksātnespējas risku. Laikam ikviens vēlētos, kaut varētu to paredzēt, taču pareģojumi un visdažādākās analīzes nevar dot simtprocentīgu rezultātu. Maksātnespēja mūsdienās aizņem stabilu vietu internēta lappusēs, zinātniskajā literatūrā, ziņās un presē. Aizvien biežāk nāks dzirdēt par kārtējo maksātnespējas vai bankrota gadījumu. Dotais darbs ir veltīts maksātnespējas procesam Luksemburgā, tas ir saistīts ar to, ka vienmēr ir interesanti uzzināt kas notiek ārpus Latvijas un kā tas notiek. Turklāt pat tādā mazā valstī kā Luksemburgā pastāv maksātnespējas situācija

    Concatenated Steganography as an Alternative Solution for Data Streams Synchronization

    No full text
    Synchronization of data streams has a significant impact on performance of systems where processing of long sequences of data items needs to be done simultaneously. Internal mechanisms (buffers, semaphores, mutually closing blocks etc.) of Data Stream Management Systems (DSMS) are usually used for attaining the synchronization. So the purpose of this paper is to present the alternative synchronization approach for Data Stream Management Systems. The developed concept is based on achievements of digital steganography in data embedding for bit streams. Looking practically, new approach is effective in cases of need to keep, transmit and process different information stream set, strongly taking into account streams’ mutual relations. Author’s approach allows increase security of stream too

    Energy Saving in Building Sector in Latvia

    No full text
    The household in Latvia is the most energy capacious sector – 40 % of the final total energy consumption has been consumed by household in 2007. According to that the energy demands in household as well as energy conservation potential are very important parts of the management and development of energy sector. Energy demand and also efficiency in housing sector generally depends on various circumstances: social sphere and state or municipal regulations, infrastructure of living area and energy supply, building envelope conditions, population’s consumption habits, thinking manner (ownership) and climate conditions. Heat energy saving arrangements is the main for the refurbishment of prefabricated housing because thermal insulation is paramount to both heat energy savings and to repairing facade damage. The advantages of heat energy saving measures, particularly with respect to prefabricated housing, are undeniably evident: •Reducing heat energy consumption by 40 to 50% is easily attained. These reductions are equal in an average reduction of the total energy consumption to 60 kWh - 80 kWh per squire meter of heated floor area per year. •A thermally insulated facade results in dry, warm exterior walls and stops weathering damage to the facade. The paper presents potential for energy saving in building sector in Latvia and the results from the realized projects of building refurbishment when building envelope element U-values have been reduced significantly by external insulation measures, and internal heating system have been rebuild. The projects illustrate the typical housing energy consumption and optimal energy saving measures for different types of buildings

    Topological Function-Architecture Co-Design of Embedded Systems

    No full text
    This paper proposes the Topological Function–Architecture Co-Design method which combines principles of co-design and Model Driven Architecture. It introduces explicit architectural and computationindependent models and formalises their evolution

    Tīmekļa aģentu izmantošana informācijas apmaiņas nodrošināšanai starp darba devēju un izglītības iestādi

    No full text
    Globalizācijas ietekmē arvien nozīmīgāka kļūst informācijas apmaiņa starp organizācijām, tai skaitā starp darba devējiem un izglītības sniedzējiem datorzinātnes un informācijas tehnoloģijas jomā. Informācijas iegūšana par darba devēju prasībām pret darbinieku izglītību ir laikietilpīgs process, ja tas tiek veikts manuāli (izglītības iestādes darbiniekam apmeklējot tīmekļa lapas un apkopojot informāciju). Tādējādi tiek ierobežota informācijas apmaiņa starp darba devēju un izglītības iestādi (ieskaitot studentus). Viens no veidiem, kā risināt šo problēmu, ir izmantot tīmekļa aģentus, kas darbojas tīmeklī, meklējot tajā informāciju par darba devēju izsludinātajām vakancēm un zināšanu pieprasījumu tajās

    Enterprise Models as Data

    No full text
    In many cases enterprise models are considered as a part of enterprise knowledge. This paper examines the status of enterprise model as an artifact that is a part of organizational information system. In this view, the enterprise models are a part of information flow in the organization, and in their static state can be regarded as data rather than knowledge. This view helps to understand why the usability of enterprise models is still quite low in spite of the availability of powerful and sophisticated enterprise modeling tools and environments that allow to construct, analyze, maintain, configure, and integrate different types of models and even generate code and configure software subsystems on the bases of models amalgamated in the tools

    An Approach to Classification of MDA Tools

    No full text
    Pēdējā laikā ir parādījies pietiekami plašs rīku klāsts, kas atbalsta ideju par programmatūras izstrādes procesa bagātināšanu ar modelēšanas principiem; tātad, programmatūras kods tiek iegūts no sistēmas modeļa. Vairāki no tiem tiek pozicionēti kā rīki, kas atbalsta MDA transformācijas tehnoloģiju. Modeļvadāmās arhitektūras sniegta pieeja nodrošina augstu abstrakcijas līmeni programmatūras izstrādes sākotnējos posmos, mēģinot atspoguļot informāciju par problēmas vidi neatkarīgi no tās turpmākās realizācijas kādā programmēšanas platformā, kā arī turpmāk ģenerējot programmas kodu formālā veidā pat bez papildus iejaukšanās no izstrādā-tāja puses. Viena no programmatūras izstrādes rīku grupām ļauj modelēt un daļēji ģenerēt programmas kodu, bet tomēr pieprasa cilvēka iejaukšanos vairākos izstrādes posmos. Savukārt, otrā rīku grupa pilnīgi atbalsta MDA piedāvātus principus par automātisko modeļu transformāciju un koda ģenerēšanu, kur cilvēka iejaukšanās ne tikai nav pieprasīta, bet pat nav iespējama. Vispārīgajā gadījumā, vadoties tikai un vienīgi no rīka specifikācijas ir grūti spriest par šī rīka atbilstību kādai no iepriekš minētājām grupām, kā arī par tajā realizēto MDA ideju līmeni. Šajā rakstā ir definēti daži skati par to, kādā veidā ir iespējams apskatīt CASE rīku saimi, kā arī definēt to piederību MDA atbalsta rīku saimei. Viens no skatiem definē programmatūras izstrādes dzīves cikla soļu secību, īpaši uzsverot MDA ideju īstenošanai nepieciešamo aktivitāšu izpildi. Turklāt, otrā skata mērķis ir sistēmas modelēšanas lomas un tās izmantošanas līmeņa definēšana kopēja izstrādes procesā. Kā arī rīku klasifikācijai ir definētas vairākas kategorijas, vadoties no kurām var noteikt MDA ideju realizācijas pakāpi apskatāmajā rīkā

    800 V DC-DC power supply for gate driver of a common two transistor leg of VSI

    No full text
    This paper presents use of a classical flyback DC DC converter topology for supplying power IGBT gate drive circuit and communication lines from high voltage DC link in modular common tow transistor leg of voltage source inverter – VSI laboratory inverter. A comparison of other DC-DC circuits is done as well

    Reconciling Software Requirements and Architectures within MDA

    No full text
    Programmatūras izstrādes pasaulē ir pieejamas nedaudzas vadlīnijas un metodes, kas domātas programmatūras prasību un arhitektūras saskaņošanai, pie tam, tādā veidā, lai izstrādātā arhitektūra atbilstu definētajām prasībām. Praktiski visas programmatūras prasību un arhitektūras saskaņošanas metodes neizmanto matemātisku pamatu saskaņošanas procesa veikšanai. Raksta galvenais mērķis ir definēt pieeju, kā saskaņot programmatūras prasības un arhitektūru modeļvadāmajā arhitektūrā. Modeļvadāmā arhitektūru programmatūras sistēmu apskata no trīs dažādiem skatu punktiem. Katrs no šiem skatu punktiem tiek attēlots ar savu modeli. Prasību un arhitektūras saskaņošanu modeļvadāmajā arhitektūrā ir iespējams veikt izmantojot topoloģisko funkcionēšanas modeli, kā arī izmantojot topoloģisko funkcionēšanas modeli ir iespējams veikt no skaitļošanas neatkarīga modeļa formālu transformāciju uz platformas neatkarīgu modeli. Topoloģiskā funkcionēšanas modeļa izmantošana saskaņošanas procesā nodrošina trasējamību starp dažādiem programmatūras artefaktiem, piemēram, starp programmatūras prasībām un arhitektūras elementiem. Raksta ietvaros ar praktiska piemēra palīdzību ir demonstrēts, ka programmatūras prasības un arhitektūru ir iespējams saskaņot saskaņošanas procesā izmantojot topoloģisko funkcionēšanas modeli. Ar praktiskā piemēra palīdzību ir parādīts, ka ir iespējams formalizēt UML diagrammas, ieviešot UML diagrammās topoloģiju, ir apskatīta topoloģijas ieviešana klašu diagrammā un topoloģiska klašu diagramma

    0

    full texts

    18,420

    metadata records
    Updated in last 30 days.
    Riga Technical University Repository
    Access Repository Dashboard
    Do you manage Open Research Online? Become a CORE Member to access insider analytics, issue reports and manage access to outputs from your repository in the CORE Repository Dashboard! 👇