University of Padua

Padua@thesis
Not a member yet
    41199 research outputs found

    Corruption schemes revealed: analysis of FCPA cases

    Get PDF

    Development and Validation of ML-based trigger algorithms

    Get PDF
    Complex machine learning (ML) based algorithms are finding their ways to low-level hardware devices like FPGAs. A neural network model is being implemented for the online identification and trigger of the passage of charged particles through a drift-tubes detector and for the reconstruction of its trajectory; such model is being tested on a set of such detectors operating at Legnaro INFN National Laboratory (LNL) with cosmic muons. The ultimate goal is to deploy this algorithm on the trigger system of the muon spectrometer of CMS at the LHC. The thesis work describes the performances of such algorithms, studying the data collected in Legnaro, and further develop it to extend its acceptance

    Realization methods of hyperpure germanium detectors with pulsed laser junction

    Get PDF
    I rivelatori al germanio iperpuro (rivelatori HPGe) sono diodi ottimizzati per il funzionamento ad elevate tensioni di polarizzazione inversa che trovano applicazione spettroscopia gamma ad alta risoluzione. Tali rivelatori sono realizzati a partire da cristalli di germanio iperpuri con concentrazione di impurezze dell'ordine di 10^{10} atomi/cm^3. A partire da questo cristallo iperpuro, il diodo viene processato drogando una delle facce con un alta concentrazione di impurezze sostitutive di tipo opposto al cristallo per ottenere una giunzione, e l'altra faccia con un'alta concentrazione di impurità dello stesso tipo del cristallo. Ci sono molte ragioni per cui il germanio è il miglior materiale per spettroscopia gamma e tra i principali, sicuramente spiccano il suo alto coefficiente di assorbimento dovuto al numero atomico maggiore del silicio, la sua elevata mobilità che va a vantaggio della riscossione soprattutto per rivelatori di grande volume; queste caratteristiche convergono in un'ottima risoluzione energetica e una buona risoluzione temporale nell'intervallo di energia rilevante per la spettroscopia gamma. L'attuale stato dell'arte è ben rappresentato da AGATA e GRETA che sono prendendo il posto dell'EUROBALL e dello spettrometro Gammasphere. I vantaggi precedenti degli array di rivelatori al germanio come AGATA e GRETA derivano dalla possibilità di analizzare la forma dell'impulso (teorema di Shockley - Ramo) confrontando la carica netta e quella indotta, consentendo l'identificazione del punto di interazione sotto il volume del segmento e quindi il tracciamento dei percorsi dei raggi all'interno dell'array, attraverso lo sviluppo di algoritmi specifici. In questa tesi viene presentato un recente metodo di drogaggio che consente la costruzione di giunzioni superficiali mediante drogaggio con fusione laser a impulsi (PLM) tecnica; tale giunzione ha il vantaggio di essere facilmente segmentata e non contamina in profondità il cristallo iperpuro, permettendogli di essere eventualmente riprocessato. Il mio lavoro in LNL ha toccato varie aree dello sviluppo e del caratterizzazione di rivelatori HPGe segmentati a grande volume. In particolare, vari rivelatori planari sono stati sviluppati per testare i nuovi processi in quanto sono molto facili da trattare grazie alla loro semplice geometria. Presenterò quindi le procedure e i risultati di varie ottimizzazioni che riguardano la costruzione e caratterizzazione mediante risultati di misure elettriche. Dopo un breve ripasso teorico, la presentazione della metodologia PLM per doping e la descrizione dei principali dispositivi di misura nel primo capitolo, I passerò a una breve e dettagliata descrizione della fabbricazione di un diodo planare HPGe nel secondo capitolo; Nel terzo capitolo mi occuperò specificamente di vari aspetti riguardanti la elaborazione della giunzione e delle varie ottimizzazioni testate; in particolare mi concentrerò sul problema dei contaminanti che si depositano sul cristallo durante il processo di fabbricazione influendo negativamente sulle prestazioni del diodo; sono stati testati nuovi metodi per un controllo e una rimozione efficaci della contaminazione. Infine, nell'ultimo capitolo descriverò le ottimizzazioni applicate mediante caratterizzazioni elettriche e presenterò modi efficaci per misurare particolari grandezze su rivelatori segmentati. ENGLISH VERSION DISSERTATION TITLE: Realization methods of hyperpure germanium detectors with pulsed laser junction KEY WORDS :HPGe, Semiconductor, Pulse laser melting, Detector ABSTRACT: The hyperpure germanium detectors (HPGe detectors) are diodes optimized for operation at high reverse polarization voltages that find application in high resolution gamma-ray spectroscopy. Such detectors are manufactured starting from hyperpure germanium crystals with impurity concentration of the order of 10 ^10 atoms/cm ^ 3 . The diode is processed by doping one of the faces with a high concentration of substitutional impurities of the opposite type to the crystal to obtain a rectifier contact and the other face with a high concentration of impurities of the same type of the crystal. There are many reasons why Germanium is the best material for gamma spectroscopy and among the main ones, certainly stand out its high absorption coefficient due to the atomic number larger than silicon, its high mobility which is to the advantage of the charge collection especially for large volume detectors; these characteristics converge in excellent energy resolution. The current state of the art is well represented by AGATA and GRETA who are taking the place of the EUROBALL and the Gammasphere spectrometer. The unprecedented advantages of germanium detector arrays such as AGATA and GRETA derive from the possibility of analyzing the pulse shape (Shockley – Ramo theorem) by comparing net and induced charge, allowing the identification of the point of interaction at the volume of the segment and therefore the tracking of the paths of the rays inside the array, through the development of specific algorithms. In this dissertation a recent doping method is presented that allows the construction of shallow junctions through doping with the pulse laser melting (PLM) technique; such a junction has the advantage of being easily segmented, and does not contaminate the hyper-pure crystal in depth, allowing it to be eventually reprocessed. My work at LNL has touched various areas of the development and characterization of segmented large volume HPGe detectors. In particular, various planar detectors have been developed to test the new processes as they are very easy to treat thanks to their simple geometry. I will therefore present the procedures and the results of various optimizations of techniques that concern the construction and characterization through results of electrical measurements. After a brief theoretical review, the presentation of the PLM methodology for doping and the description of the main measuring devices in the first chapter, I will move on to a brief and detailed description of the diode manifacturing starting from a planar crystal in the second chapter; In the third chapter I will deal specifically with various aspects concerning the processing of the rectifying contact and the various optimizations tested; in particular I will focus on the problem of contaminants depositing on the crystal during the manufacturing process that negatively affecting the performance of the diode; new methods have been tested for effective control and removal of contamination. Finally, in the last chapter I will describe the applied optimizations by means of electrical characterizations and I will present efficient ways to measure particular quantities on segmented detectors

    Creazione di valore tramite le operazioni di M&A: il caso Kering

    Get PDF

    p-adic methods for rational points on curves of genus g <maggiore o uguale>2

    Get PDF
    Nel 1922 Mordell ha congetturato che ogni curva di genere maggiore o uguale a 2 ha solo un numero finito di punti a coordinate razionali. Ciò è stato dimostrato da Faltings nel 1983, ma prima di lui Chabauty ha dimostrato, nel 1941, che questo è vero nell'ipotesi aggiuntiva che il rango di Mordell-Weil della varietà Jacobiana su Q sia strettamente minore del genere della curva. Sebbene questo non dimostri la congettura di Mordell, queste idee hanno portato alla creazione di nuovi metodi per la ricerca di punti razionali su curve. Oltre agli aspetti teorici, si studieranno anche le applicazioni alla ricerca delle soluzioni di alcune equazioni diofantee

    Incremental clustering of continuous perceptions

    No full text
    This thesis aims to develop a framework for the incremental clustering of the perceptions ofan agent. The agent moves in a simulated environment and collects data about its position and its surroundings, in particular the egocentric images seen by its on-board camera. In this context, clustering is useful to group together the perceptions of a same object, in particular to recognize objects which have already been seen by the agent. This task is performed with the aid of a neural network, pre-trained to recognize if two perceptions are associated to a same object. In this thesis we analyze the tuning and training performed for the neural network, the clustering algorithm and its performance

    15,643

    full texts

    41,199

    metadata records
    Updated in last 30 days.
    Padua@thesis
    Access Repository Dashboard
    Do you manage Open Research Online? Become a CORE Member to access insider analytics, issue reports and manage access to outputs from your repository in the CORE Repository Dashboard! 👇