Portail HAL CSTB
Not a member yet
    2178 research outputs found

    Experimental investigation on the fire behaviour of wooden facades

    No full text
    International audienceThe paper presents results of large-scale facade fire tests which were performed during "Firewall" research project. This project, funded by the French National Research Agency (ANR), aims to provide a better understanding of flame propagation mechanisms along vertical walls. Two large-scale fire tests were carried out on a non-combustible and combustible facade. The tests were conducted with a high fire power of approximately 950 kW, generated by a natural gas burner. Spruce wood was used as testing material in the case of combustible facade. The gas temperature, heat release rate, in-depth temperature, total and radiative heat flux and char depth were measured to evaluate the thermal actions and the influence of wood on the flame spread. These findings are presented in this publication and compared with the results of other works of literature.</div

    Analyse comparative de solutions pour améliorer le confort thermique d'un bâtiment résidentiel neuf en climats futurs tout en limitant l'impact carbone

    No full text
    International audienceThis article presents a comparative study of summer thermal comfort and carbon impact between the cities of Nîmes and Paris, considering current and future climatic conditions as well as the urban heat island effect. Different conventional solutions such as mobile and fixed solar shading, air fans or heat pumps, and an innovative indirect evaporative cooling solution are evaluated. The results of the study show that, among the various solutions tested, air fans, indirect evaporative cooling, and water-to air heat pump emerge as particularly effective strategies for improving thermal comfort while limiting carbon impact, compared with the use of air-to-air heat pumps.Cet article présente une étude comparative de solutions pour limiter les surchauffes dans un bâtiment neuf, avec une évaluation du confort d'été dans les logements et de l'impact carbone des différentes solutions dans les villes de Nîmes et Paris, en tenant compte des conditions climatiques actuelles et futures ainsi que de l'effet de l'îlot de chaleur urbain. Les solutions évaluées sont les protections solaires mobiles et fixes, les brasseurs d'air, des pompes à chaleur et une solution de rafraichissement évaporatif indirect. Les résultats de l'étude mettent en évidence que, parmi les différentes solutions testées, les brasseurs d'air, la solution de refroidissement évaporatif indirect et la PAC air-eau collective émergent comme des stratégies particulièrement efficaces pour améliorer le confort thermique tout en limitant l'impact carbone en comparaison à l'utilisation de PAC air-air à l'échelle des logements

    Essai et validation d’une méthode opérationnelle de quantification des volumes et flux de sédiments de l’assainissement pluvial

    No full text
    International audienceLes enjeux de l’artificialisation des sols et du changement climatique ont conduit à l’aménagement d’un vaste panel d’ouvrages de gestion centralisée et décentralisée des eaux pluviales (bassins, noues, tranchées…), offrant une variété étendue de services (régulation hydraulique, traitement…). Néanmoins, l’accumulation chronique de sédiments est une problématique majeure de ce mode de gestion des eaux pluviales. Retenues par décantation et/ou filtration mécanique au sein de ces ouvrages, ces matières particulaires peuvent mettre en péril leur bon fonctionnement hydraulique et épuratoire, rendant les sujets de l’extraction et du devenir de ces sédiments prégnants. Cependant, l’absence de méthode opérationnelle pour quantifier les volumes et flux de sédiments accumulés est un obstacle pour prévoir les fréquences de curage adaptées au fonctionnement des ouvrages et assurer le devenir des matériaux extraits. La plupart des investigations en hydrologie urbaine ont recours à des mesures en continu et/ou une instrumentation complexe, difficilement généralisables. Cette étude montre que la quantification du volume de dépôt et l’estimation des taux d’accumulation peuvent être réalisées par des relevés ponctuels de l’épaisseur de la couche de sédiments, couplés à une interpolation géostatistique par krigeage. La mise en œuvre de la méthode sur un bassin d’infiltration des eaux pluviales a permis d’en éprouver la faisabilité et la fiabilité. Les résultats obtenus semblent pertinents vis-à-vis des précédentes études disponibles pour ce même bassin. L’estimation est particulièrement sensible à la masse volumique apparente des sédiments, considérée ici comme une variable aléatoire distribuée uniformément entre les valeurs minimale et maximale mesurées : des travaux complémentaires pourront en améliorer la précision, en étudiant son éventuelle répartition spatiale. En outre, si cette technique fait ses preuves pour différents types d’ouvrages et de contextes, il sera possible d’estimer rapidement des taux d’accumulation dans les ouvrages, voire des flux de sédiments générés pour différents types de bassins versants. Cela ouvre la voie au développement d’outils pour accompagner les gestionnaires d’ouvrages vers une gestion optimisée des résidus de l’assainissement pluvial

    Perception of Ghosting in LED Lighting: Modeling the visibility of Ghosting (or Phantom Array Effect)

    No full text
    International audienceHave you ever noticed a strange visual effect when driving behind a vehicle with LED-based (light-emitting diode) rear lights at night? The rear lights of the vehicles appear as a trail of lights when you make eye movements across them while navigating the road. Or, have you noticed decorative lighting that "repeats" itself when wandering and looking around in the city? This phenomenon, known as the phantom array effect (or ghosting), is defined by CIE (International Commission on Illumination) as "the change in perceived shape or spatial layout of objects, induced by a light stimulus whose luminance or spectral distribution fluctuates with time, for a non-static observer in a static environment." The term "non-static" here means that the observer moves their eyes by making fast eye movements (i.e., saccades). The phantom array effect results from making saccades over a temporally modulated light source, and it is most easily observed in low-light situations

    Méthodologie prospective pour l'optimisation multicritère de la rénovation énergétique des bâtiments

    No full text
    International audienceConference paper presenting my thesis works, during the IBPSA France 2024 conference.This study presents an innovative approach to multi-criteria optimization of renovation strategies, integrating thermal comfort into economic and environmental assessments. Thanks to prospective climate series, cooling needs and associated renovation actions are particularly studied. The analyses of the Pareto fronts on the case study of a single-family home revealtrade-offs between thermal comfort, carbon footprint andtotalcost. It highlights, in this case, the need to renovate the heating system and insulate the walls at the same time, while air conditioning and the switch to double flow ventilation are optional. The inclusion of a future climate model year, without a heat wave, aggravates the thermal discomfort of renovation strategies but does not change the choice of optimal strategies. This initial study will soon be supplemented by the addition of new renovation strategies, forward-looking emission factors and heat wave weather sequences.Document de conférence présentant mes travaux de thèse, lors de la conférence IBPSA France 2024.Cette étude présente une approche novatrice d'optimisation multicritère des stratégies de rénovation, intégrant le confort thermique dans les évaluations économiques et environnementales. Grâce à des séries climatiques prospectives,les besoins de refroidissementet les gestes de rénovation associés sont particulièrement étudiés.L'analyse des frontsde Paretosur l’étude de cas d’une maison individuellerévèle des compromis entre confort thermique, empreinte carboneet coûtglobal. Elle met en lumière, pour ce cas particulier,la nécessité de rénover en même temps le système de chauffage etd’isoler les murs, tandis que la climatisation et le passage à une ventilation double flux sont facultatifs. L’intégration d’une année-type climatique future, sans canicule,aggrave l’inconfort thermiquedes stratégies de rénovation mais ne modifie pas le choix des stratégies optimales. Cette étude initiale sera prochainement complétée par l’ajout denouvelles stratégies de rénovation, de facteurs d’émissions prospectifs ainsi que de séquences climatiques caniculaires

    Advancing Urban Building Energy Model Validation: A Comprehensive Multi-Period Approach for Dynamic Outputs

    No full text
    International audienceThis article presents a new methodology for the validation of the dynamic outputs, such as load profiles, of urban building energy models (UBEM) through a multi-period approach. This approach consists of evaluating models across different periods to ensure their accuracy and reliability under various conditions. Applied to Dimosim, a UBEM co-developed by the CSTB and Efficacity, through a case study of the Blagnac heating network in France, the methodology effectively identifies uncertainties within validation periods and the relative model validity over different periods, enhancing reliability and interpretability of UBEM validation. Perspectives for the methodology include its application to diverse urban contexts and the integration of model calibration into the current methodology.Cet article présente une nouvelle méthodologie pour valider les sorties dynamiques, telles que les courbes de charge, des modèles de simulation énergétique urbaine (MSEU) à travers une approche de validation multi-période. Cette approche consiste à évaluer les modèles sur différentes périodes afin d'assurer leur précision et fiabilité dans diverses conditions. Appliquée à Dimosim, un MSEU co-développé par le CSTB et Efficacity, via une étude de cas sur le réseau de chauffage de Blagnac en France, la méthodologie identifie efficacement les incertitudes au sein des périodes de validation et la validité relative du modèle sur différentes périodes, améliorant ainsi la fiabilité et l'interprétabilité de la validation des MSEU. Les perspectives de la méthodologie portent sur son application sur des contextes urbains différents et l'intégration de la calibration du modèle à la méthodologie actuelle

    0

    full texts

    2,178

    metadata records
    Updated in last 30 days.
    Portail HAL CSTB
    Access Repository Dashboard
    Do you manage Open Research Online? Become a CORE Member to access insider analytics, issue reports and manage access to outputs from your repository in the CORE Repository Dashboard! 👇