NIST Digital Archives
Not a member yet
    149436 research outputs found

    Simulation of the performance of a fundamental neutron physics beamline at the high flux isotope reactor

    No full text
    We study the expected performance of the proposed fundamental neutron physics beamline at the upgraded High Flux Isotope Reactor at Oak Ridge National Laboratory. A curved neutron guide transmits the neutrons from the new cold source into a guide hall. A novel feature of the proposed guide is the use of vertical focussing to increase the flux for experiments that require relatively small cross-section beams. We use the simulation code IB to model straight, multi-channel curved, and tapered guides of various m values. Guide performance for the current NPDGamma and proposed abBA experiments is evaluated

    Details of the 1998 watt balance experiment determining the Planck constant

    No full text
    The National Institute of Standards and Technology (NIST) watt balance experiment completed a determination of Planck constant in 1998 with a relative standard uncertainty of 87 x 10(-9) ( k = 1), concurrently with an upper limit on the drift rate of the SI kilogram mass standard. A number of other fundamental physical constants with uncertainties dominated by this result are also calculated. This paper focuses on the details of the balance apparatus, the measurement and control procedures, and the reference calibrations. The alignment procedures are also described, as is a novel mutual inductance measurement procedure. The analysis summary discusses the data noise sources and estimates for the Type B uncertainty contributions to the uncertainty budget. Much of this detail, some historical progression, and a few recent findings have not been included in previous papers reporting the results of this experiment

    Measurement of the loss and depolarization probability of UCN on beryllium and diamond like carbon films

    No full text
    Currently several institutes worldwide are working on the development of a new generation of ultracold neutron (UCN) sources. In parallel with source development, new materials for guiding and storage of UCN are developed. Currently the best results have been achieved using Ni-58, Be, solid O-2 and low temperature Fomblin oil (LTF). All of these materials have their shortcomings like cost, toxicity or difficulty of use. A novel very promising material is diamond like carbon (DLC). Several techniques exist to coat surfaces, and industrial applications ( e. g., for extremely hard surfaces) are already wide spread. Preliminary investigations using neutron reflectometry at PSI and Los Alamos yielded a critical velocity for DLC of about 7 m/s thus comparable to Beryllium. A low upper limit of depolarization probability for stored polarized UCN has been measured at the PF2 facility of the Institut Laue-Langevin ( ILL) by North Carolina State University ( NCSU), Los Alamos National Laboratory (LANL), and Petersburg Nuclear Physics Institute (PNPI), thus making it also a good material for storage and guidance of polarized UCN. Still missing is the loss probability per bounce. We will be able to extract this number and a more stringent value for the depolarization from our experiment thus proving the suitability of DLC as a wall material for a wide range of UCN applications

    UCN production with a single crystal of ortho-deuterium

    No full text
    The present paper reports on the preliminary experimental results concerning a new concept of ultracold neutron production with a single crystal converter of ortho-deuterium lying in the ground rotational state at the low temperature of about 10 K, which should make it possible to utilize a guided cold neutron beam instead of irradiating the converter material in the inside of high radiation fields. The successful observation of the clear Bragg scattering pattern from the single crystal converter and the reasonable results from the first experimental trial of the ultracold neutron production with the single crystal are shown

    Polarized He-3 spin filters for slow neutron physics

    No full text
    Polarized He-3 spin filters are needed for a variety of experiments with slow neutrons. Their demonstrated utility for highly accurate determination of neutron polarization are critical to the next generation of betadecay correlation coefficient measurements. In addition, they are broadband devices that can polarize large area and high divergence neutron beams with little gamma-ray background, and allow for an additional spin-flip for systematic tests. These attributes are relevant to all neutron sources, but are particularly well-matched to time of flight analysis at spallation sources. There are several issues in the practical use of He-3 spin filters for slow neutron physics. Besides the essential goal of maximizing the He-3 polarization, we also seek to decrease the constraints on cell lifetimes and magnetic field homogeneity. In addition, cells with highly uniform gas thickness are required to produce the spatially uniform neutron polarization needed for beta-decay correlation coefficient experiments. We are currently employing spin-exchange ( SE) and metastability-exchange ( ME) optical pumping to polarize He-3, but will focus on SE. We will discuss the recent demonstration of 75 % He-3 polarization, temperature-dependent relaxation mechanism of unknown origin, cell development, spectrally narrowed lasers, and hybrid spin-exchange optical pumping

    Determination of the neutron lifetime using magnetically trapped neutrons

    No full text
    We report progress on an experiment to measure the neutron lifetime using magnetically trapped neutrons. Neutrons are loaded into a 1.1 T deep superconducting Ioffe-type trap by scattering 0.89 nm neutrons in isotopically pure superfluid He-4. Neutron decays are detected in real time using the scintillation light produced in the helium by the beta-decay electrons. The measured trap lifetime at a helium temperature of 300 mK and with no ameliorative magnetic ramping is substantially shorter than the free neutron lifetime. This is attributed to the presence of neutrons with energies higher than the magnetic potential of the trap. Magnetic field ramping is implemented to eliminate these neutrons, resulting in an 833(-63)(+74)s trap lifetime, consistent with the currently accepted value of the free neutron lifetime

    A superconducting magnet UCN trap for precise neutron lifetime measurements

    No full text
    Finite-element methods along with Monte Carlo simulations were used to design a magnetic storage device for ultracold neutrons (UCN) to measure their lifetime. A setup was determined which should make it possible to confine UCN with negligible losses and detect the protons emerging from beta-decay with high efficiency: stacked superconducting solenoids create the magnetic storage field, an electrostatic extraction field inside the storage volume assures high proton collection efficiency. Alongside with the optimization of the magnetic and electrostatic design, the properties of the trap were investigated through extensive Monte Carlo simulation

    Monte Carlo study of the abBA experiment: Detector response and physics analysis

    No full text
    The abBA collaboration proposes to conduct a comprehensive program of precise measurements of neutron beta-decay coefficients a (the correlation between the neutrino momentum and the decay electron momentum), b (the electron energy spectral distortion term), A (the correlation between the neutron spin and the decay electron momentum), and B (the correlation between the neutron spin and the decay neutrino momentum) at a cold neutron beam facility. We have used a GEANT4-based code to simulate the propagation of decay electrons and protons in the electromagnetic spectrometer and study the energy and timing response of a pair of Silicon detectors. We used these results to examine systematic effects and find the uncertainties with which the physics parameters a, b, A, and B can be extracted from an over-determined experimental data set

    Temperature dependence of the Hall and longintudinal resistances in a quantum Hall resistance standard

    No full text
    We present detailed measurements of the temperature dependence of the Hall and longitudinal resistances on a quantum Hall device [( GaAs( 7)] which has been used as a resistance standard at NIST. We find a simple power law relationship between the change in Hall resistance and the longitudinal resistance as the temperature is varied between 1.4 K and 36 K. This power law holds over seven orders of magnitude change in the Hall resistance. We fit the temperature dependence above about 4 K to thermal activation, and extract the energy gap and the effective g-factor

    Development of a position sensitive neutron detector with high efficiency and energy resolution for use at high-flux beam sources

    No full text
    We are developing a high-efficiency neutron detector with 1 cm position resolution and coarse energy resolution for use at high-flux neutron source facilities currently proposed or under construction. The detector concept integrates a segmented He-3 ionization chamber with the position sensitive, charged particle collection methods of a MicroMegas detector. Neutron absorption on the helium produces protons and tritons that ionize the fill gas. The charge is amplified in the field region around a wire mesh and subsequently detected in current mode by wire strips mounted on a substrate. One module consisting of a high-voltage plate, a field-shaping high-voltage plate, a grid and wire strips defines a detection region. For 100% efficiency, detector modules are consecutively placed along the beam axis. Analysis over several regions with alternating wire strip orientation provides a two-dimensional beam profile. By using He-3, a 1/nu absorption gas, each axial region captures neutrons of a different energy range, providing an energy-sensitive detection scheme especially useful at continuous beam sources

    0

    full texts

    149,436

    metadata records
    Updated in last 30 days.
    NIST Digital Archives
    Access Repository Dashboard
    Do you manage Open Research Online? Become a CORE Member to access insider analytics, issue reports and manage access to outputs from your repository in the CORE Repository Dashboard! 👇