Revista Internacional de Contaminación Ambiental
Not a member yet
    1371 research outputs found

    ANÁLISIS DE UN IMPUESTO AL CO2 SOBRE GENERADORAS TERMOELÉCTRICAS USANDO INDICADORES DE COSTO-EFECTIVIDAD

    Get PDF
    In 2017, Chile introduced a CO2 tax on emissions from fixed sources with a thermal power ≥ 50 MW. Therefore, this study uses cost-effectiveness indicators to assess whether investing in carbon capture and sequestration technology is an attractive option for each of the thermoelectric generators with the objective of reducing its CO2 emissions and tax burden. The results indicate that a tax of US5/tCO2isfullyinfectiveinreducingemissionsbecausethermoelectricgeneratorsonlyreducetheiremissionsiftaxesweresetatapproximatelyUS5/tCO2 is fully infective in reducing emissions because thermoelectric generators only reduce their emissions if taxes were set at approximately US30/tCO2. Thus, it can be concluded that the current tax only serves for collecting rather than for reducing emissions.En el año 2017 se introdujo en Chile un impuesto a las emisiones de CO2 provenientes de fuentes fijas con potencia térmica ≥ 50 Megawatts (MW). Por lo anterior, el presente estudio utiliza indicadores de costo-efectividad para evaluar si invertir en tecnología de captura y secuestro de carbono es una opción atractiva para cada una de las generadoras termoeléctricas con el objetivo de reducir sus emisiones de CO2 y su carga tributaria. Los resultados indican que el actual impuesto de 5 dólares americanos/tCO2 es completamente inefectivo para reducir emisiones ya que las generadoras termoeléctricas sólo reducen emisiones si se fijan impuestos cercanos a 30 dólares/tCO2. Así, se puede concluir que el impuesto actualmente aplicado en Chile sirve sólo para recaudar y no para reducir emisiones

    EVALUACIÓN DE LA CALIDAD DEL AGUA Y DE LA RIBERA EN DOS CUENCAS TRIBUTARIAS DEL RÍO TUXCACUESCO, JALISCO, MÉXICO

    Get PDF
    It has been documented that in Mexico 80% of aquatic ecosystems, including water bodies such as rivers, are under some degree of contamination. It has been detected that the main pollutants are organic matter, nutrients (nitrogen and phosphorous) and microorganisms (faecal coliforms). Addressing this problem is of vital importance for the conservation of aquatic ecosystems and for improving the quality of life of the inhabitants of the surroundings. In this sense the lack information on the quality status of aquatic ecosystems in the Tuxcacuesco river basin, in the satate of Jalisco, is very scarce and non-existent for its tributary basins. Therefore, in the present study the objective was to infer the quality of the aquatic ecosystems of two tributary basins (Tonaya and Apulco) of the Tuxcacuesco river, in Jalisco, Mexico, by using two indices. The first an index of biotic integrity based on the presence or absence of families of aquatic macroinvertebrates, and the second an index to assess the ecological status and quality of riverbanks, the riverbank quality index (RQI). Two samplings were carried out at four sites, in the month of October 2015 (end of the rainy season) and February of the year 2016 (beginning of the dry season), in which aquatic macroinvertebrates were collected and the RQI index was applied. In addition, physical and chemical parameters (pH, electrical conductivity and flow rate) were evaluated and the total nitrogen content was determinated in each site. By means of a canonical correspondence analysis, it was evidenced that the flow and the electrical conductivity are the environmental variables that have the greater relation with the order of the families of macroinvertebrates found. In general, the ecological status of the banks is poor in the two tributary basins, and the nitrogen content in the waters exceeds the permissible limits for potable use and agricultural irrigation. Regarding the application of the biotic integrity index, it was found that in most of the sites there is the presence of organic contamination.Se ha documentado que en México 80% de los ecosistemas acuáticos, entre ellos cuerpos de agua como los ríos, se encuentran bajo algún grado de contaminación. Así se ha detectado que los principales contaminantes son materia orgánica, nutrientes (nitrógeno y fósforo) y microorganismos (coliformes fecales). Atender esta problemática es de vital importancia para la conservación de los ecosistemas acuáticos y para mejorar la calidad de vida los pobladores aledaños. En este sentido la información sobre el estado de calidad de los ecosistemas acuáticos en la cuenca del río Tuxcacuesco, Jalisco es muy escasa e inexistente para sus cuencas tributarias. Por ende, en el presente estudio el objetivo fue inferir la calidad de los ecosistemas acuáticos de dos cuencas tributarias (Tonaya y Apulco) del Río Tuxcacuesco, Jalisco, México mediante la utilización de dos índices. El primero un índice de integridad biótica basado en la presencia o ausencia de familias de macroinvertebrados acuáticos y el segundo un índice para valorar el estado ecológico y la calidad de las riberas fluviales, el índice de calidad de riberas (RQI, por sus siglas en inglés). Se realizaron dos muestreos en cuatro sitios, en el mes de octubre del año 2015 (final de la temporada lluviosa) y febrero del año 2016 (inicio de la temporada seca), en los cuales se recolectaron macroinvertebrados acuáticos y se aplicó el índice RQI. Además, se evaluaron parámetros fisicos y químicos (pH, conductividad eléctrica y caudal) y se determinó el contenido de nitrógeno total en cada sitio. Mediante un análisis de correspondencia canónica, se evidenció que el caudal y la conductividad eléctrica son las variables ambientales que tienen mayor relación con el ordenamiento de las familias de macroinvertebrados encontradas. En general, el estado ecológico de las riberas es pobre en las dos cuencas tributarias y el contenido de nitrógeno en las aguas rebasa los límites permisibles para uso potable y riego agrícola. En cuanto a la aplicación del índice de integridad biótica se encontró que en la mayoría de los sitios existe presencia de contaminación orgánica

    Carta a la Editora

    Get PDF

    ELECTROSYNTHESIS OF SODIUM AND POTASSIUM FERRATE FOR THE TREATMENT OF INDIGO BLUE AQUEOUS SOLUTIONS AND DENIM WASTEWATER

    Get PDF
    Synthetic dyes are widely used in the textile industry. It is estimated that about 2-50 %of these dyes are lost during the dying process and released in the effluents. These compounds are highly colored and can cause severe contamination of water sources. In this study, ferrate has been employed for the treatment of indigo blue aqueous solutions and denim wastewater. The electrosynthesis of ferrate was carried out using a 24 factorial design and the optimal conditions were found: current density of 100 mA/cm2, room temperature, kind and concentration of electrolyte, NaOH 20 M. Under these conditions, 6.89 g/L (41.54 mM) of ferrate was produced. The successful synthesis of ferrate was confirmed using infrared spectroscopy, ultraviolet spectroscopy, and cyclic voltammetry. The electrosynthesized sodium ferrate (Na2FeO4)and potassium ferrate (K2FeO4) were evaluated in a jar test. The maximum dye removal percentage (> 77 %) was achieved using Na2FeO4 at a dose of 300 mg/L. In denim wastewater, the best color removal efficiency was 92.51 % using 200 mg/L of K2FeO4 at 30 min. The increased biodegradability index (0.98) after treatment by K2FeO4 confirmed that the biorefractory compounds were oxidized/removed.Synthetic dyes are widely used in the textile industry. It is estimated that about 2-50 %of these dyes are lost during the dying process and released in the effluents. These compounds are highly colored and can cause severe contamination of water sources. In this study, ferrate has been employed for the treatment of indigo blue aqueous solutions and denim wastewater. The electrosynthesis of ferrate was carried out using a 24 factorial design and the optimal conditions were found: current density of 100 mA/cm2, room temperature, kind and concentration of electrolyte, NaOH 20 M. Under these conditions, 6.89 g/L (41.54 mM) of ferrate was produced. The successful synthesis of ferrate was confirmed using infrared spectroscopy, ultraviolet spectroscopy, and cyclic voltammetry. The electrosynthesized sodium ferrate (Na2FeO4)and potassium ferrate (K2FeO4) were evaluated in a jar test. The maximum dye removal percentage (> 77 %) was achieved using Na2FeO4 at a dose of 300 mg/L. In denim wastewater, the best color removal efficiency was 92.51 % using 200 mg/L of K2FeO4 at 30 min. The increased biodegradability index (0.98) after treatment by K2FeO4 confirmed that the biorefractory compounds were oxidized/removed

    ANÁLISIS DEL CONTENIDO DE BENCENO EN LAS GASOLINAS Y ESTIMACIÓN DE EMISIONES DE ESTE COMPUESTO AL AMBIENTE

    Get PDF
    Use of gasolines has a primordial interest in the ecological area, due to the emissions generated by combustion engines. In order to maintain a good air quality, it is necessary to control several gasoline quality parameters. Mexico City is a metropolis with 4 421 797 vehicles registered in 2014, therefore air quality problems are constantly present. Mexican gasoline quality specifications are regulated by Mexican Official Standard NOM-016-CRE-2016. Benzene, one of the compounds regulated by NOM-016-CRE-2016, is known to be a carcinogenic agent. Moreover, it is considered that the presence of benzene in gasoline can affect population health due to its volatility, which gets it to be in contact with the atmosphere and consequently with the population. In this work, the average amount of benzene present in gasoline commercialized in Mexico City was quantified by ASTM D5769-15. Results showed it was 0.361 % in Magna gasoline, whereas the average amount of benzene present in imported gasoline was 0.55 % and 1.28 % in the gasoline produced locally by PEMEX National Refineries System. This value was higher than imported and commercialized gasoline. In addition, the estimation of benzene emissions by mobile sources was 354.79 t during 2017.El uso de gasolinas es un tema de gran interés en el ámbito ecológico debido a las emisiones que generan los automotores, por lo que el control de los parámetros que regulan la calidad de las gasolinas es necesario para mantener una buena calidad del aire. La Ciudad de México (CdMx) es una metrópoli con una flota vehicular registrada de 4 421 797 (2014), factor que influye en la calidad del aire. Las especificaciones de calidad de la gasolina en México están reguladas por la NOM-016-CRE-2016. Uno de los compuestos regulados por esta norma es el benceno, que se considera un agente carcinogénico. Se ha determinado que la presencia de benceno en la gasolina puede afectar la salud de la población, ya que al ser un compuesto volátil se evapora con gran facilidad, poniéndose en contacto con la atmósfera y por consecuencia con la población. En este trabajo se cuantificó la cantidad de benceno presente en las gasolinas que se comercializan en la CdMx mediante el uso de la técnica ASTM D5769-15 y se determinó que el contenido promedio de este compuesto fue de 0.361 % para la gasolina Magna, mientras que el contenido promedio de benceno en las gasolinas importadas fue de 0.55 %. En cuanto a las gasolinas producidas en el Sistema Nacional de Refinación, el contenido de benceno fue de 1.288 %, valor superior al de las gasolinas importadas y comercializadas en la CdMx. Asimismo, se estimó una emisión de 354.79 t de benceno durante 2017 debido al uso de automóviles en la CdMx

    EVALUACIÓN DE LA CALIDAD BACTERIOLÓGICA DE Crassostrea gigas IMPLANTADAS EN EL ESTUARIO DE BAHÍA BLANCA, ARGENTINA

    Get PDF
    The Pacific oyster, Crassostrea gigas was introduced into many coastal ecosystems of Argentina. Its range of distribution in Bahía Blanca´s estuary is uncertain, and there is evidence of its continued expansion. The aim of this work was to evaluate the bacteriological quality of the oyster in the inner area of the estuary of Bahía Blanca, and of the water and sediments where it grows. Two sampling stations were established: Club Náutico (CN) and Puerto Cuatreros (PC). Subsurface water, surface sediments and oysters were collected from the intertidal zone from June 2015 to June 2018. In the three matrices, counts of Escherichia coli (Ec) and detection of Vibrio spp. were done. In addition, Salmonella spp. was searched in the oyster tissue. In the two stations, an accumulation of Ec in oysters and in sediments was evidenced. In addition to the high values of Ec in CN, the presence of Salmonella in oysters was detected. In all the matrices of both stations Vibrio spp. were isolated, including V. cholerae and V. parahaemolyticus. The oyster beds studied in the estuary are a very accessible place and the specimens are of good size, make them attractive for informal harvesting. However, according to the bacteriological results, 66 % of the samples of PC oysters and 100 % of CN do not comply with the current legislation in Argentina, representing a potential risk for human health.La ostra del Pacífico, Crassostrea gigas, fue introducida en muchos ecosistemas costeros de Argentina. Su rango de distribución en el estuario de Bahía Blanca es incierto, existiendo evidencias de su continua expansión. El objetivo de este trabajo fue evaluar la calidad bacteriológica de la ostra en la zona interna del estuario de Bahía Blanca y del agua y sedimentos donde crece. Se establecieron dos estaciones de muestreo: Club Náutico (CN) y Puerto Cuatreros (PC), donde se realizaron 21 campañas entre junio 2015 y junio 2018. Se recolectaron agua subsuperficial, sedimentos superficiales y ostras de la zona intermareal. En las tres matrices se hicieron recuentos de Escherichia coli (Ec) y detección de Vibrio spp. Además, en el tejido de ostras se buscó Salmonella spp. En las dos estaciones, se evidenció la acumulación de Ec en ostras y en sedimentos. Se detectaron altos valores de Ec en las tres matrices y la presencia de salmonelas en CN. En todas las matrices de ambas estaciones se aislaron especies del género Vibrio, incluyendo V. cholerae y V. parahaemolyticus. Los bancos de ostras estudiados en el estuario están en un lugar muy accesible y los animales son de buen tamaño, lo que los hace atractivos para la recolección informal. Sin embargo, de acuerdo con los resultados bacteriológicos, el 66 % de las muestras de ostras de PC y el 100 % de CN no cumplen con la legislación vigente en Argentina, constituyendo un riesgo potencial para la salud humana

    ENSAYOS MECÁNICOS SOBRE MORTEROS CON AGREGADOS DE PLÁSTICO RECICLADO DOSIFICADOS SEGÚN MODELO DE CONDUCTIVIDAD TÉRMICA

    Get PDF
    Plastic waste constitutes 10 % of the solid waste worldwide. The use of plastic aggregates in concrete improves some properties such as thermal insulation and specific weight, although it produces a decrease in strength. In this work, mixtures with plastic aggregates of residual origin were dosed to satisfy thermal insulation requirements. For this purpose, a simplified model was made, calculating the required plastic thicknesses in an equivalent wall of 18 cm thick. Then, specimens were molded and tested by bending and compression. The results confirmed that the incorporation of plastic produced a drop in compressive and flexural strength, except in the case of pellets. Under the proposed multilayer wall model, a theoretical thickness of plastic between 2.4 and 6 cm was required to achieve the desired thermal insulation, compared to 37 cm that a wall exclusively made of mortar would have required. However, only one mix reached the minimum strength required for the construction of panels. It was concluded that the rounded aggregates exhibited better behavior than the leaf-shaped aggregates and that the model used for the dosage of plastic aggregates should be improved and contrasted with experimental results in a future paper.Los residuos de plástico constituyen el 10 % de los residuos sólidos a nivel mundial. El uso de agregados de plástico en el hormigón mejora algunas propiedades como el aislamiento térmico y el peso específico, aunque produce disminución de la resistencia a la compresión. En este trabajo se dosificaron mezclas con agregados de plástico reciclado de origen residual para satisfacer requisitos de aislamiento térmico. Para ello se desarrolló un modelo simplificado, calculando los espesores de plástico requeridos en un muro equivalente de 18 cm de espesor. Luego se moldearon probetas y se ensayaron a flexión y compresión. Los resultados confirmaron que la incorporación de plástico produjo una caída de la resistencia a la compresión y la flexión, excepto en el caso de gránulos (pellets). Se requirió un espesor teórico de plástico —con el modelo de muro multicapa propuesto— de 2.4 a 6 cm para lograr el aislamiento térmico deseado, frente a los 37 cm que hubiese requerido un muro realizado exclusivamente con mortero. Sin embargo, sólo una mezcla alcanzó la resistencia mínima requerida para la construcción de paneles. Se concluyó que los agregados redondeados exhibieron mejor comportamiento que los agregados con forma de hojuelas y que el modelo utilizado para la dosificación de agregados de plástico debería ser mejorado y contrastado con resultados experimentales en un trabajo futuro.

    ALTERACIONES DEL CICLO MENSTRUAL DE ADOLESCENTES EXPUESTAS NO OCUPACIONALMENTE A UNA MEZCLA DE PLAGUICIDAS DE UNA ZONA AGRÍCOLA DE SAN LUIS POTOSÍ, MÉXICO. ESTUDIO PILOTO

    Get PDF
    Persistent organic pollutants are a group of chemical compounds of global concern due to the health damages caused by the exposure to them. Their capacity as endocrine disrupters is one of their main characteristics, being women in reproductive age the most vulnerable population. The aim of the present study was to evaluate the effect of exposure to a mixture of pesticides in the menstrual cycle of a sample of 29 teenagers between the ages of 12 and 17 years old from El Refugio, San Luis Potosi, Mexico, a community whose predominant activity is agriculture. The participants were trained to record in a diary/logbook all the events related to their menstrual cycle. Serum levels of sex hormones were measured by chemiluminescence, and plasma concentrations of organochlorine (OC) pesticides and the level of dialkyl phosphates metabolites (DAPs) of organophosphorus agrochemicals presented in urine were measured through gas chromatography-mass spectrometry. Around 41.6 % of the participants presented some alteration in their hormonal levels, mainly of follicle-stimulating hormone and progesterone. Of these, OC pesticides in plasma were detected in 62 % (ΣOC = 1651.25 ng/g of lipid), and 66 % had detectable levels of DAPs (ΣDAP = 153.82 mg/g of creatinine). Together, these results suggest damage to the endocrine system that could be generated by exposure to a mixture of OC and organophosphorus pesticides could generate.Los contaminantes orgánicos persistentes son un grupo de compuestos químicos de preocupación mundial debido a los daños a la salud que ocasiona la exposición a los mismos. Es destacable su capacidad como perturbadores endocrinos, siendo las mujeres en edad reproductiva una de las poblaciones más vulneradas. El objetivo del presente estudio fue evaluar el efecto de la exposición a una mezcla de plaguicidas en el ciclo menstrual de adolescentes residentes en El Refugio, San Luis Potosí, México, comunidad cuya actividad preponderante es la agricultura. La población de estudio estuvo conformada por 29 adolescentes en un intervalo de edad 12 a 17 años, quienes fueron capacitadas para registrar en un diario/bitácora todos los eventos relacionados con su ciclo menstrual. Se midieron los niveles séricos de las hormonas sexuales por quimioluminiscencia, así como las concentraciones plasmáticas de los plaguicidas organoclorados (OC) y los niveles urinarios de los metabolitos dialquilfosfatos (DAP) de los agroquímicos organofosforados mediante cromatografía de gases acoplada a espectrofotometría de masas. El 41.6 % de las participantes tuvo alguna alteración en los niveles de la hormona folículo estimulante y de progesterona. De éstas, el 62 % presentó plaguicidas OC en plasma (ΣOC = 1651.25 ng/g de lípidos) y el 66 % tuvo niveles detectables de DAP (ΣDAP = 153.82 mg/g de creatinina). Estos resultados reflejan daño endocrino que pudiera estar asociado a la exposición a una mezcla de plaguicidas organoclorados y organofosforados

    DECOLORACIÓN SONOQUÍMICA SINÉRGICA DEL ANARANJADO DE METILO UTILIZANDO TRICLOROMETANO EN DOS REACTORES ULTRASÓNICOS

    Get PDF
    The discoloration of methyl orange (AM), an azo dyer with mutagenic properties, is studied. The action of trichloromethane (HCCl3) (TM) is analyzed as a synergistic agent, using batch and continuous ultrasonic reactors. It is demonstrated that the sonochemical discoloration of AM is widely favored by the addition of low concentrations of HCCl3. In the case of the batch reactor, discolorations of 17 and 98 % were obtained without and with TM, and the respective kinetic constants were statistically different. In the continuous reactor, discolorations of 7 % and greater than 80 % were reached without and with the addition of TM, respectively, once the reactor entered a steady state.Se estudia la decoloración del anaranjado de metilo (AM), un colorante azoico con propiedades mutagénicas. Se analiza la acción del triclorometano (HCCl3) (TM) como agente sinérgico, utilizando un reactor ultrasónico por lotes y otro continuo. Se demuestra que la decoloración sonoquímica del AM es ampliamente favorecida por la adición de bajas concentraciones de HCCl3. En el caso del reactor por lotes, se obtuvieron decoloraciones del 17 y 98 % sin y con triclorometano, y las constantes cinéticas respectivas fueron estadísticamente diferentes. En el reactor continuo se alcanzaron decoloraciones del 7 % y superiores al 80 % sin y con TM, respectivamente, una vez que el reactor entró en estado estacionario

    BIODEGRADACIÓN DE RESIDUOS DE ACEITE USADO DE COCINA POR HONGOS LIPOLÍTICOS: UN ESTUDIO IN VITRO

    Get PDF
    The waste used cooking oil (WUCO) is one of the most serious factors of water pollution because it is able to create a layer that hinders the passage of oxygen and is difficult to remove. In order to demonstrate the capacity and efficiency of in vitro biodegradation of WUCO by lipolytic fungi, a study was conducted with three genera of fungi from industrial effluents of palm oil (Penicilium, Aspergillus and Amorphoteca). The efficiency of experimental biodegradation was evaluated in a container with equal parts (300 mL) of WUCO and tap water, where they were inoculated: ± 104 conidia/mL for individual experiments, ± 503 conidia/mL for a dual evaluation (two genera) and ± 33 300 conidia/mL for an evaluation of the three fungi. For each experiment three replicates were performed and all were incubated at 27 and 30 ºC for up to eight days. Lipolytic activity levels among genera of fungi were significant during the first days of the experiment (p < 0.05), normalizing to eighth day (p = 0.573). The combination of the three fungi improved the efficiency of biodegradation (p < 0.001), comparable with the eight-day evaluation of individual experiments (p = 0.012). All experiments at 27 ºC had better efficiency (p < 0.001). The three lipolytic fungi have high capacity and efficiency of biodegradation of WUCO in vitro after eight days of incubation at 27 ºC.Los residuos de aceites usados de cocina (RAUC) son uno de los más graves factores de contaminación del agua porque son capaces de crear una capa que dificulta el paso de oxígeno y es difícilmente eliminable. Con el objetivo de demostrar la capacidad y eficiencia de biodegradación in vitro de RAUC mediante hongos lipolíticos se realizó un estudio con tres géneros hongos provenientes de efluentes industriales de aceite de palma (Penicilium, Aspergillusy Amorphoteca). Se evaluó la eficiencia de biodegradación en un contenedor con partes iguales (300 mL) de RAUC y agua de grifo donde se inocularon ± 104 conidios/mL en los experimentos con un género, ± 503 conidios/mL con dos géneros y ± 33 300 conidios/mL con los tres géneros. Para cada experimento se realizaron tres repeticiones y todos fueron incubados a 27 y 30 ºC hasta por ocho días.  Los niveles de actividad lipolítica entre géneros de hongos difirieron durante los primeros días del experimento (p < 0.05) normalizándose hacia el octavo día (p = 0.573). La combinación de tres géneros mejoró la eficiencia de biodegradación (p < 0.001), comparable con la evaluación a los 8 días de los experimentos individuales (p = 0.012). Todos los experimentos a 27 ºC tuvieron mejor eficiencia que los de 30 ºC (p < 0.001). Los tres hongos lipolíticos tienen alta capacidad y eficiencia de biodegradación de RAUC in vitro luego de ocho días de incubación a 27 ºC.

    1,154

    full texts

    1,371

    metadata records
    Updated in last 30 days.
    Revista Internacional de Contaminación Ambiental
    Access Repository Dashboard
    Do you manage Open Research Online? Become a CORE Member to access insider analytics, issue reports and manage access to outputs from your repository in the CORE Repository Dashboard! 👇