eData: the STFC Research Data Repository
Not a member yet
948 research outputs found
Sort by
Maltose
Inelastic Neutron Scattering spectrum of Maltose, C12H12O11.H20, measured on the TFXA instrument
Carbazole
Inelastic Neutron Scattering spectrum of Carbazole, C₁₂H₉N, measured on the TOSCA instrument
Dimethylformamide
Inelastic Neutron Scattering spectrum of Dimethylformamide, C₃H₇NO, measured on the TOSCA instrument
ß-Carotene
Inelastic Neutron Scattering spectrum of ß-Carotene, C₄₀H₅₆, measured on the TOSCA instrument. Type 1 glassy carbon (carbonization temperature is <1000 C).
5-Azauracil H2O
Inelastic Neutron Scattering spectrum of 5-Azauracil H2O, C3H3N3O2.H2O, measured on the TOSCA-1 instrument
Potassium zinc borohydride dichloride
Inelastic Neutron Scattering spectrum of Potassium zinc borohydride dichloride, KZn(BH₄)Cl₂, measured on the TOSCA instrument
EMP generated by high intensity ultrashort laser-solid interaction on the Vulcan Petawatt Data set
The data provide is that used while generating a time-frequecny analysis method for EMP (electromagnetic pulses ) generated from a high intensity laser-solid interaction. The data set includes additional data where the parameters of the laser are varied. This data is voltage-time oscilloscope traces from Moebius loops, which respond to the rate of change of magnetic field, and are the same as used by M.J. Mead et al (Rev. Sci. Instru. Vol75, pp4225-4227, 2004) and are connected to a Tektronix 15GHz oscilloscope. The cables used are double sheathed coaxial cable which limits signal frequencies to less than 4Ghz. Two different targets were used, made of gold or glass. The gold target was 100 micron thick across 500 micron diameter hole in a copper substrate 100 micron thick that is 3 mm by 7 mm. The glass target was Borrosilicate Glass that was 3mm thick by 3mm tall and 0.5mm wide. This data was generated during a Vulcan Petawatt laser experiment February 2017 (13210073).STFC: access time: experiment (13210073)
EPSRC: grant: EP/K022415/1 (Advanced laser-ion acceleration strategies towards next generation healthcare)
EPSRC: grant: EP/J003832/1 (Multi-PetaWatt Laser-Plasma Interactions: A New Frontier in Physics
Ethyne
Inelastic Neutron Scattering spectrum of Ethyne, C2H2, measured on the TOSCA instrument.
Acetylen
Hypoxanthine
Inelastic Neutron Scattering spectrum of Hypoxanthine, C₅H₄N₄O, measured on the TOSCA instrument
Anthraflavic acid
Inelastic Neutron Scattering spectrum of Anthraflavic acid, C₁₄H₈O₄, measured on the TFXA instrument