eData: the STFC Research Data Repository
Not a member yet
948 research outputs found
Sort by
Data for Mol. Phys. Vol. 96, p1159 (1999)
The data in this archive relate to the paper
T. YAMAGUCHI, K. HIDAKA & A. K. SOPER (1999) The structure of liquid methanol revisited: a neutron diffraction experiment at −80 °C and +25 °C, Molecular Physics, 96:8, 1159-1168, DOI: 10.1080/00268979909483060
plus erratum
T. YAMAGUCHI, K. HIDAKA & A. K. SOPER (1999) The structure of liquid methanol revisited: a neutron diffraction experiment at -80 °C and +25 °C, Molecular Physics, 97:4, 603-605, DOI: 10.1080/0026897990948285
Fenestrindane
Inelastic Neutron Scattering spectrum of Fenestrindane, C29H20, measured on the TOSCA instrument
1,4-Dimethoxytriptindane
Inelastic Neutron Scattering spectrum of 1,4-Dimethoxytriptindane, C25H20O2, measured on the TOSCA instrument
Caprolactam-D10
Inelastic Neutron Scattering spectrum of Caprolactam-D10, C6D10HNO, measured on the TOSCA instrument
Lanthanum lithium oxyhydride
Inelastic Neutron Scattering spectrum of Lanthanum lithium oxyhydride, HLa2LiO3, measured on the TOSCA instrument
Time-resolved measurements of fast electron recirculation for relativistically intense femtosecond scale laser-plasma interactions
This data was generated from a 2013 Gemini experiment (Central Laser Facility) investigating fast electron transport in solid targets. The data was obtained from an optical probe that was reflected off the rear surface of the targets and collected using a single lens imaging system, before being split between three cameras that were filtered by wavelength. A 10 mm apodised portion of a second Gemini laser was used as a rear surface optical probe, incident at an angle of 40 degrees relative to target normal in a p-polarised orientation.
The beam was chirped to a pulse length of between 0.3 and 5 ps by detuning the compressor. At the shortest pulse duration (300 fs) the temporal resolution was ~100 fs. By using a linear chirp, a linear relationship between wavelength and probe timing could be assumed, the shortest wavelengths (~780nm) probing earliest in time, the longest ~820nm) latest in time. In order to separate the time windows, three CCD cameras were using in the imaging line, with a different bandpass filter in front of each camera (see Green et al. J. Inst. 2014 http://dx.doi.org/10.1088/1748-0221/9/03/P03003 for more details). An f=40 cm achromatic lens was used to image the target rear surface, yielding a spatial resolution of 6um at 800 nm, and a magnification of x7.
The timing of the rear surface probe relative to the main pulse was also varied with the use of a timing slide. In order to make quantitative measurements of the rear surface reflectivity a reference image of each target was first obtained by just firing the probe beam of the Gemini laser. A second image was then taken with both the probe beam and main interaction pulse incident on the target, with the timing between the two varied on each shot. By normalising the on-shot reflectivity map with the reference reflectivity map obtained from the undisturbed foil, a clear 2D measurement of any change in target reflectivity was obtained.EP/J003832/1
EP/M011372/
Cadmium methanesulfonate dideuterate
Inelastic Neutron Scattering spectrum of Cadmium methanesulfonate dideuterate, Cd(CH3SO3)2(D2O)2, measured on the TOSCA instrument
Cellulose
Inelastic Neutron Scattering spectrum of Cellulose, (C6H10O5)n, measured on the TOSCA instrument.
Commercial material (Avicell PH-101, 50 micron particle size, 5 wt % water content
Borazine
Inelastic Neutron Scattering spectrum of Borazine, B3N3H6, measured on the TOSCA instrument.
1,3,5,2,4,6-Triazatriborinane. Back scattering data only
Diplatinum spermine
Inelastic Neutron Scattering spectrum of Diplatinum spermine, C10H26Cl4N4Pt2, measured on the TOSCA instrument.
[æ-N,N'-bis(3-aminopropyl)butane-1,4-diamine-?4N,N':N'',N''']bis[dichloridoplatinum(II)], Pt2Sp