Repositorio Institucional de CIMAV (Centro de Investigación en Materiales Avanzados)
Not a member yet
2546 research outputs found
Sort by
SÍNTESIS Y EVALUACIÓN DE COBALTITA DE MANGANESO EN LA PRODUCCIÓN DE HIDRÓGENO POR MEDIO DE LA SEPRACIÓN DE LA MOLÉCULA DEL AGUA POR FOTOCATÁLISIS
ESTUDIO DE NANOPARTÍCULAS METÁLICAS Y METALES TOTALES EN AGUA RESIDUAL Y LODO DE DOS DEPURADORAS DE PALMA DE MALLORCA, ESPAÑA
Resumen
Las nanopartículas (NPs) metálicas son utilizadas ampliamente en diferentes actividades y productos de consumo, siendo las NPs de óxido de zinc (ZnO-NPs), dióxido de titanio (TiO2-NPs) y de plata (Ag-NPs) las más utilizadas. Sus principales aplicaciones son en cosméticos, medicina, alimentos, prendas de vestir y remediación ambiental. El constante uso de las NPs ha propiciado una preocupación sobre su liberación al medio ambiente y se han identificado las Plantas de Tratamiento de Aguas Residuales (PTAR) como importantes fuentes de NPs. Por tal motivo, el presente estudio evaluó la presencia de NPs metálicas (Ag-NPs, TiO2-NPs y ZnO-NPs) y de metales totales (Ag, As, Au, Ba, Be, Cd, Co, Cr, Cu, Li, Mn, Mo, Ni, Pb, V y Zn) en agua residual y lodo de dos PTAR (PTAR 1 y PTAR 2) ubicadas en Palma de Mallorca, España.
El protocolo de análisis desarrollado para la determinación de NPs se basa en el uso de técnicas múltiples, en el cual se aplica ultrafiltración, diálisis, digestión ácida asistida por microondas y detección por Espectrometría de Emisión Óptica con Plasma Inductivamente Acoplado (ICP-OES). Los metales totales fueron determinados mediante ICP-OES con previa digestión ácida de la muestra.
Las NPs fueron determinadas en muestras de agua residual recolectadas mensualmente desde agosto-2018 a junio-2019, obteniendo concentraciones de ZnO-NPs desde inferiores al límite de detección (<LD) hasta 123 ± 4 μg L-1 para PTAR 1 y de <LD hasta 66 ± 4 μg L-1 para PTAR 2. Las Ag-NPs no fueron detectadas en las muestras. La cuantificación de las TiO2-NPs no pudo realizarse, sin embargo, se identificaron mediante la técnica de Microscopía Electrónica de Barrido (SEM).
Los metales totales se determinaron en muestras de agua residual y lodo correspondientes a los meses de enero-2018 a junio-2019. En las muestras de agua residual no se detectaron Ag, As, Au, Be, Cd, Co, ni Mo. En los influentes de la PTAR 1 se encontraron tres máximos distintivos, en enero y agosto 2018 y en abril-2019, los metales con estos tres máximos son el Cr, Cu, Mn, Ni y Zn. En los influentes de la PTAR 2 se presentaron dos máximos, en enero-2018 y en abril-2019 para el Ba, Cu, Mn, Ni y Zn.Abstract
Metallic nanoparticles (NPs) are widely used in several consumer products and activities, being the zinc oxide NPs (ZnO-NPs), titanium dioxide (TiO2-NPs) and silver (Ag-NPs) the most used. Their main applications are in cosmetics, medicine, food industry, textiles and environmental restauration. Due to the constant use of NPs, there is an increasing concern about the release of NPs to the environment. The Wastewater Treatment Plants (WWTP) have been identified as important sources of NPs. Therefore, in this work, the presence of metallic NPs (Ag-NPs, TiO2-NPs and ZnO-NPs) and total metals (Ag, As, Au, Ba, Be, Cd, Co, Cr, Cu, Li, Mn, Mo, Ni, Pb, V and Zn) in wastewater and sewage sludge of two WWTP (WWTP 1 and WWTP 2) in Palma de Mallorca, Spain, have been evaluated.
The analysis protocol developed for the NPs determination is based in the use of multiple techniques, i.e. ultrafiltration, dialysis, microwave assisted acid digestion and detection exploiting Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). The total metal content was determined by ICP-OES in samples previously acid digested.
The NPs were determined in monthly samples of wastewater from august-2018 to June-2019, obtaining concentrations of ZnO-NPs from below of limit of detection (<LOD) to 123 ± 4 μg L-1 for WWTP 1 and from <LOD to 66 ± 4 μg L-1 for WWTP 2. The Ag-NPs were not detected in the samples. The quantification of TiO2-NPs could not be performed; however, they were identified by scanning electron microscopy (SEM).
The total metal content was determined in samples of wastewater and sewage sludge, corresponding to January-2018 until June-2019. Ag, As, Au, Be, Cd, Co and Mo did not detect in wastewater samples. Three distinctive maximums were found in the influents of WWTP 1, corresponding to January and August-2018 and April-2019, the metals with these three maximums are Cr, Cu, Mn, Ni and Zn. In the influents of the WWTP 2 two maximums were presented, in January-2018 and in April-2019 for Ba, Cu, Mn, Ni and Zn
Diseño, construcción y caracterización de un cristal fotónico bidimensional de Si-ZnO con propiedades ópticas transmisivas unidireccionales.
Resumen.
En este trabajo se diseñará, construirá y se caracterizará estructuralmente
y ópticamente, un cristal fotónico bidimensional con índice de refracción
efectivo variable dependiente de las coordenadas espaciales. Esto
con la finalidad de que la propagación de las ondas luminosas en el rango
visible-infrarrojo cercano (VIS-NIR) del espectro electromagnético en este
medio fotónico presente un comportamiento unidireccional debido a los
efectos de difracción y a la variación espacial del índice de refracción. En
consecuencia, la transmitancia óptica en este medio material ocurrirá de
manera selectiva en el dominio de las frecuencias
Estudio de la Degradación de Lixiviados del Relleno Sanitario de la Ciudad de Chihuahua Mediante Oxidación Fenton
Síntesis de SnO2 Nanométrico con Morfología Macroporosa
Resumen
El procedimiento para preparar three-dimensionally ordered macroporous (3DOM) de SnO2. Se sintetizaron microesferas de PMMA por
medio de una polimerización por emulsión, una vez obtenido PMMA se disperso en una solución de SnCl4-5H2O con la cual obtenemos una plantilla.
Al crear esta plantilla mejoro la porosidad a base de nanopartículas de SnO2 una vez retirado las esferas del PMMA por medio de un tratamiento térmico
Uso de pruebas no destructivas para el análisis micro estructural en calderas
Resúmen
Se realizó la evaluación en tubos de una caldera
actuatubular por medio de pruebas no destructivas con la
finalidad de obtener la razón de su falla. Los resultados
obtenidos de pruebas a través de ultrasonido mostraron
que la falla de los tubos se debió al fenómeno de
termofluencia