Revistas Científicas UMH (Universitas Miguel Hernandez)
Not a member yet
1296 research outputs found
Sort by
SENSITIVITY ANALYSIS ON HEAT EXCHANGERS SELECTION AND ITS INFLUENCE ON THE EFFICIENCY OF A TRANSCRITICAL CO2 CYCLE WITH INDIRECT DEDICATED MECHANICAL SUBCOOLING
This work evaluates through numerical modeling, the efficiency of an air-to-water heat pump that operates using a transcritical CO2 cycle assisted by an indirect dedicated mechanical subcooling (IDMS) cycle, with R1234ze(E) as the refrigerant. The research aims to analyze how the size of the heat exchangers used as the evaporator and the condenser for the IDMS cycle affects the overall efficiency of the system. A numerical model previously developed in Matlab® is used to modify the refrigerant and compressor of the IDMS cycle and to determine the optimal number of evaporator and condenser plates that maximize the efficiency of the whole system. The compressor model is derived from manufacturer correlations, whereas the models for the heat exchangers are obtained through a parametric study developed using IMST-ART® to characterize their operating parameters based on their number of plates and the inlet conditions of water and refrigerant. Once the models are developed, they are integrated into the model of the overall system to find the heat exchanger sizes that maximize the efficiency of the system.This work evaluates through numerical modeling, the efficiency of an air-to-water heat pump that operates using a transcritical CO2 cycle assisted by an indirect dedicated mechanical subcooling (IDMS) cycle, with R1234ze(E) as the refrigerant. The research aims to analyze how the size of the heat exchangers used as the evaporator and the condenser for the IDMS cycle affects the overall efficiency of the system. A numerical model previously developed in Matlab® is used to modify the refrigerant and compressor of the IDMS cycle and to determine the optimal number of evaporator and condenser plates that maximize the efficiency of the whole system. The compressor model is derived from manufacturer correlations, whereas the models for the heat exchangers are obtained through a parametric study developed using IMST-ART® to characterize their operating parameters based on their number of plates and the inlet conditions of water and refrigerant. Once the models are developed, they are integrated into the model of the overall system to find the heat exchanger sizes that maximize the efficiency of the system
CÁLCULO DE DISTANCIAS DE SEGURIDAD PARA LAS PRUEBA DE PRESIÓN DE RESISTENCIA Y DE ESTANQUEIDAD DE UNA INSTALACIÓN FRIGORÍFICA PARA UN CENTRO LOGÍSTICO
Cuando se ejecuta una nueva instalación frigorífica previa a la puesta en servicio, es obligatorio realizar una comprobación de que la instalación es segura y estanca. Para ello el RD 552/2019, en la “Instrucción F-09 ensayos, pruebas y revisiones previas a la puesta en servicio”, nos especifica los ensayos de la instalación. Los componentes deberán ser sometidos a una prueba de resistencia, y las tuberías requieren un ensayo a presión neumática. Los valores adoptados para la prueba de resistencia y estanqueidad varían en función de las líneas a probar. En materia de seguridad y salud es necesario establecer las medidas preventivas necesarias para garantizar la seguridad de los trabajadores, tanto aquellos que intervienen en dichos trabajos como los adyacentes. Para ello se realiza el cálculo de las distancias de seguridad de las líneas a considerar durante las pruebas en la instalación en un centro logístico consistente en un sistema de enfriamiento de NH3/Glicol al 35%, de tipo indirecto cerrado. Además, la instalación frigorífica contará con una central compresora, compuesta por compresores semiherméticos los cuales utilizan R-744 (CO2) como refrigerante para abastecer a los servicios frigoríficos pertenecientes al régimen de congelados. Para ello se ha utilizado el criterio conforme la Norma ASME PCC-2-2018. Reparación de equipos a presión y tuberías. Apéndices 501-II. y 501-III
LA BANDEJA DE PLÁSTICO ACTIVA CON ACEITES ESENCIALES ENCAPSULADOS MEJORA LA CALIDAD DE LOS ARÁNDANOS FRESCOS REFRIGERADOS
La producción de arándanos (principalmente en la zona de Huelva) en España ha aumentado en la última década debido a las altas propiedades saludables de estos frutos azules. Sin embargo, la baja temperatura óptima para el almacenamiento postcosecha de los arándanos implica elevados costes energéticos durante su conservación y transporte. Sin embargo, los aceites esenciales vegetales (AE) utilizados como tratamientos poscosecha pueden preservar la calidad del producto, lo que puede permitir aumentar la temperatura de ajuste de las cámaras frigoríficas. El envasado activo con AE es una excelente alternativa a los ineficaces tratamientos de lavado con AE (baja solubilidad de los AE en agua, alta sensibilidad de las muestras a los daños mecánicos, eliminación de la capa cerosa natural antimicrobiana de los arándanos, etc.). Por lo tanto, estudiamos la calidad (firmeza, microbiana y sensorial) de los arándanos durante el almacenamiento refrigerado (4 ºC) hasta 7 días utilizando envases activos de AE (con una mezcla encapsulada de AE de carvacrol:AE de orégano:AE de canela, 70:10:20) o envases de plástico comerciales. Los arándanos envasados con envases activos mostraron un 20% más de firmeza que las muestras de control al séptimo día. La carga de levaduras de las muestras dentro del envase activo era 1,1 unidades logarítmicas inferior a la de las muestras de control al cabo de 7 días. En general, los envases activos preservaron mejor la calidad de los arándanos durante el almacenamiento en frío, lo que se correlacionó con las puntuaciones sensoriales de las muestras
EFECTOS DE LÁMINAS ACTIVAS DE PAPEL EN LA CALIDAD DE LOS TOMATES CHERRY DURANTE EL ALMACENAMIENTO EN FRÍO
Los aceites esenciales vegetales (AE) tienen varias propiedades tecnológicas, como antimicrobianas, antioxidantes, inhibidoras de enzimas, etc., que luego son muy valoradas en el sector alimentario como alternativa de conservación sostenible a los controvertidos aditivos químicos. El envasado activo con AE es una técnica con gran potencial para alargar la vida útil de frutas y hortalizas. Para ello, estudiamos la aplicación de láminas de papel activo (kraft) (incluyendo complejos de inclusión de β-ciclodextrina con una mezcla de timol:eugenol (50:50)) para conservar tomates cherry (también conocidos como tomates uva) hasta 14 días a 10 ºC. La calidad del tomate se evaluó mediante análisis fisicoquímicos (sólidos solubles, acidez titulable y pH), de firmeza, de color y microbianos. El crecimiento microbiano de psicrófilos, mesófilos y mohos estuvo muy controlado, con recuentos ≈1 unidad logarítmica más bajos en comparación con el control tras 14 días de almacenamiento refrigerado, en los tomates en los que se utilizaron las láminas activas. Además, también se controló el crecimiento de enterobacterias y levaduras, con recuentos hasta 0,6 unidades logarítmicas inferiores tras 14 días de almacenamiento refrigerado. Además, las láminas activas no afectaron (p>0,05) a la calidad fisicoquímica (sólidos solubles, acidez titulable y pH), la firmeza o el color de los tomates. En conclusión, el envasado en láminas activas de AE controló el crecimiento microbiano durante el almacenamiento refrigerado de los tomates
SIMULACIÓN DINÁMICA DE DIFERENTES ESTRATEGIAS DE CONTROL EN SISTEMA DE CALEFACCIÓN TODO AGUA CON BOMBA DE CALOR
Este trabajo analiza distintas configuraciones de control y regulación para una instalación de calefacción todo agua, a escala unifamiliar, con bomba de calor geotérmica. Las simulaciones se han realizado con el software OpenModelica. Para la selección y parametrización de algunos componentes se ha recurrido también a la librería Buildings.
Se analizan 3 estrategias de control diferentes, contemplando la posibilidad de utilizar en el circuito hidráulico de calefacción una circuladora de velocidad constante o variable, así como un control sobre la bomba de calor basado en una temperatura de retorno constante o una temperatura de salida variable. Una vez seleccionados los componentes y las estrategias de control diferentes, se evalúa su grado de eficiencia energética durante un periodo anual en base al cálculo del SCOP. Además, se observó que la estrategia de control considerada afectaba también a la frecuencia y duración de los ciclos de arranque y parada de la bomba de calor
HAPPENING: an efficient cascade heat pump system for multifamily buildings
An innovative hybrid heat pump system is presented as a novel solution for multifamily building heating system retrofitting. This system is very efficient on the one hand thanks to its innovative configuration in cascade, minimum thermal losses and on the other hand, the maximization of local solar energy self-consumption due to decoupling generation and consumption and applying smart control strategies. It is aimed at facilitating retrofitting of existing heating systems in multifamily buildings, enabling an efficient decarbonization. Three variations of the system have been designed, installed, and tested in real buildings across Europe, within the H2020 project “HAPPENING”. The project is now under monitoring phase and the preliminary results are positive, demonstrating the high efficiency of the conceptAn innovative hybrid heat pump system is presented as a novel solution for multifamily building heating system retrofitting. This system is very efficient on the one hand thanks to its innovative configuration in cascade, minimum thermal losses and on the other hand, the maximization of local solar energy self-consumption due to decoupling generation and consumption and applying smart control strategies. It is aimed at facilitating retrofitting of existing heating systems in multifamily buildings, enabling an efficient decarbonization. Three variations of the system have been designed, installed, and tested in real buildings across Europe, within the H2020 project “HAPPENING”. The project is now under monitoring phase and the preliminary results are positive, demonstrating the high efficiency of the concept
ANÁLISIS DEL FLUJO TÉRMICO EN TUBERÍAS CON ENFRIAMIENTO ASIMÉTRICO MEDIANTE HEATT®
Los flujos térmicos en condiciones de contorno asimétrico son frecuentes en todo tipo de conducciones en condiciones reales, dando lugar a distribuciones de temperaturas también asimétricas en el seno del fluido. Ejemplos de esto en instalaciones frigoríficas serían conducciones de frigorífero defectuosamente aisladas a temperaturas negativas, con producción de hielo en una de sus caras, etc. En el presente trabajo se estudia la distribución de temperaturas en el seno de tuberías de líquidos de uso en instalaciones frigoríficas (frigorígenos, frigoríferos u otros productos) sometidas a condiciones térmicas asimétricas en condiciones de flujo laminar. Para ello se hace uso de la herramienta informática de libre uso HEATT®, basada en el Método de Simulación por Redes, que proporciona el mapa térmico en diferentes secciones de la tubería, lo que permite determinar la porción de tubería cuyas condiciones se alejan de las de operación
LEGAL PROTECTION OF LINGUISTIC MINORITY UNDER DISCRIMINATION: THE CASE OF ANGLOPHONE CAMEROON
The minority English-speaking population in Cameroon, where French is the majority language, has a number of political, economic, and social complaints that collectively make up the "Anglophone problem." These grievances are described using the terms discrimination, marginalization, and second-class citizenship. The right to speak English in Cameroon must always be upheld as a fundamental right. To protect the rights of minorities, Cameroon has established a number of laws. Since Cameroon and many other countries have ratified a number of human rights instruments, it is the state\u27s duty to safeguard all the rights guaranteed by these instruments, including those of minorities. As demonstrated by the current crisis, another escalation in that cycle, there are several political systemic deficiencies that need to be closed if Cameroon is to grow as a single nation. Greater localized control over political and financial resources might be necessary to achieve this. In order to better serve the needs of citizens, existing institutions and leadership structures must become more accommodating
O ponto de deflexão da frequência cardíaca corresponde ao limiar ventilatório durante o teste máximo baseado em água em mulheres não treinadas
Background: The research problem addresses the investigation of the correlation and accuracy of the Heart Rate Deflection Point (HRDP) method compared to the Ventilatory Threshold (VT) method in predicting the Anaerobic Threshold (AT) during water-based stationary running maximal tests performed by untrained women.
Goals: This study compared heart rate (HR), oxygen uptake (VO2), percentage of maximal heart rate (%HRmax), percentage of maximal oxygen uptake (%VO2max) and cadence (CAD) related to the anaerobic threshold (AT) during a water-based stationary running maximal test performed by untrained women between HRDP and VT methods. In addition, the correlations between both methods were assessed for all variables.
Method: Fifty-six untrained women (40.2 ± 16.3 years) started the protocol at a cadence of 85 beats per minute (b.min-1) for 3 min with subsequent increments of 15 b.min-1every 2 min until exhaustion.
Results: There was no difference in the HR, VO2, %HRmax, %VO2max and CAD related to AT between the HRDP and the VT methods. Moreover, significant relationships were found between the methods to determine the AT (r=0.61-0.95).
Conclusions: In conclusion, the HRDP method may be an accurate predictor of AT in untrained women performing the water-based stationary running maximal test.Antecedentes: El problema de investigación aborda la correlación y precisión del método del Punto de Deflexión de la Frecuencia Cardíaca (HRDP) comparado con el método del Umbral Ventilatorio (VT) en la predicción del Umbral Anaeróbico (AT) durante pruebas máximas de carrera estacionaria en agua realizadas por mujeres no entrenadas.
Objetivos: Este estudio comparó la frecuencia cardíaca (HR), el consumo de oxígeno (V̇O2), el porcentaje de la frecuencia cardíaca máxima (%HRmax), el porcentaje del consumo máximo de oxígeno (%VO2max) y la cadencia (CAD) relacionados con el AT durante una prueba máxima de carrera estacionaria en agua por mujeres no entrenadas entre los métodos HRDP y VT. Además, se evaluaron las correlaciones entre ambos métodos para todas las variables.
Método: Cincuenta y seis mujeres no entrenadas (40,2 ± 16,3 años) iniciaron el protocolo con una cadencia de 85 latidos por minuto (b.min-1) durante 3 min, con incrementos subsiguientes de 15 b.min-1 cada 2 min hasta el agotamiento.
Resultados: No hubo diferencia en la HR, VO2, %HRmax, %VO2max y CAD relacionados con el AT entre los métodos HRDP y VT. Además, se encontraron relaciones significativas entre los métodos para determinar el AT (r=0.61-0.95).
Conclusiones: El método HRDP puede ser un predictor preciso del AT en mujeres no entrenadas realizando la prueba máxima de carrera estacionaria en agua. Palabras clave: ejercicio acuático, umbral anaeróbico, respuestas cardiorrespiratoriasIntrodução: O problema de pesquisa aborda a investigação da correlação e precisão do método do Ponto de Deflexão da Frequência Cardíaca (HRDP) em comparação com o método do Limiar Ventilatório (VT) na predição do Limiar Anaeróbio (AT) durante testes máximos de corrida estacionária em água realizados por mulheres não treinadas.
Objetivos: Este estudo comparou a frequência cardíaca (HR), o consumo de oxigênio (VO2), a porcentagem da frequência cardíaca máxima (%HRmax), a porcentagem do consumo máximo de oxigênio (%VO2max) e a cadência (CAD) relacionados ao AT durante um teste máximo de corrida estacionária em água por mulheres não treinadas entre os métodos HRDP e VT. Além disso, as correlações entre ambos os métodos foram avaliadas para todas as variáveis. Método: Cinquenta e seis mulheres não treinadas (40,2 ± 16,3 anos) iniciaram o protocolo com uma cadência de 85 batimentos por minuto (b.min-1) por 3 min, com incrementos subsequentes de 15 b.min-1 a cada 2 min até a exaustão. Resultados: Não houve diferença na HR, V̇O2, %HRmax, %VO2max e CAD relacionados ao AT entre os métodos HRDP e VT. Além disso, foram encontradas relações significativas entre os métodos para determinar o AT (r=0.61-0.95).
Conclusões: O método HRDP pode ser um preditor preciso do AT em mulheres não treinadas realizando o teste máximo de corrida estacionária em água.Introdução: O problema de pesquisa aborda a investigação da correlação e precisão do método do Ponto de Deflexão da Frequência Cardíaca (HRDP) em comparação com o método do Limiar Ventilatório (VT) na predição do Limiar Anaeróbio (AT) durante testes máximos de corrida estacionária em água realizados por mulheres não treinadas.
Objetivos: Este estudo comparou a frequência cardíaca (HR), o consumo de oxigênio (VO2), a porcentagem da frequência cardíaca máxima (%HRmax), a porcentagem do consumo máximo de oxigênio (%VO2max) e a cadência (CAD) relacionados ao AT durante um teste máximo de corrida estacionária em água por mulheres não treinadas entre os métodos HRDP e VT. Além disso, as correlações entre ambos os métodos foram avaliadas para todas as variáveis. Método: Cinquenta e seis mulheres não treinadas (40,2 ± 16,3 anos) iniciaram o protocolo com uma cadência de 85 batimentos por minuto (b.min-1) por 3 min, com incrementos subsequentes de 15 b.min-1 a cada 2 min até a exaustão. Resultados: Não houve diferença na HR, V̇O2, %HRmax, %VO2max e CAD relacionados ao AT entre os métodos HRDP e VT. Além disso, foram encontradas relações significativas entre os métodos para determinar o AT (r=0.61-0.95).
Conclusões: O método HRDP pode ser um preditor preciso do AT em mulheres não treinadas realizando o teste máximo de corrida estacionária em água
EL USO FRAUDULENTO DE SIGNOS DISTINTIVOS, LESIVO PARA EL DERECHO DE MARCA, CON MOTIVO DE LA SENTENCIA DEL TRIBUNAL SUPREMO DE 13 DE JULIO 2023
Commentary on the sentence in which a serious offence against industrial property was committed. The accused stored in his commercial establishment, trimmings and objects that imitated the lettering and distinctive signs of fashion brands. In this way, consumers were confused and the trademark rights of the affected companies were infringed.Comentario de la sentencia en la que se produce un grave delito contra la propiedad industrial. El acusado almacenaba en su establecimiento comercial, fornituras y objetos que imitaban las grafías y los signos distintivos de las marcas de moda. De esta forma se generaba confusión a los consumidores y se lesionaba los derechos de marca de los que eran titulares las mercantiles afectadas