LSU Health Digital Scholar (Louisiana State Univ.)
Not a member yet
8182 research outputs found
Sort by
Transforming Spaces: Interventions in Furniture Layouts to Reduce Patient Violence on a Psychiatry Unit Using a Quality Improvement Approach at University Medical Center
Benefits in Performing Penicillin Challenges in the Outpatient Clinic to Reduce Hospital Costs
From RAGs to Riches: AI-Powered Retrieval Augmented Generation (RAG) for Just-in-Time Learning and Accelerated Onboarding in High Turnover ICUs
Impact of Brief Educational Supplement of Colon Cancer Screening Alternatives and Its Impact on Orders Placed by Primary Care Providers
Utilization of Lung Cancer Screening Methods in the Primary Care Setting and Proposing Methods for Improvement
Analysis of Wireless Obturation Units for Endodontic Purposes
Introduction: The objectives of endodontic therapy are to eliminate bacteria in the root canal system and obturate the prepared canal system in three dimensions. The objective of this study was to compare obturation units for (a) the rate of heating and (b) peak temperature reached. Methods: Seven configurations were examined: B&L-Alpha II Down-pack; B&L-Beta Mini Backfill; Elements-IC Down-pack and Backfill; and Woodpecker Fi-P Down-pack, Fi-G Backfill, and Fi-E Backfill. The experimental system was comprised of a thermocouple (Omega, 5TC-TT-K-40-36), MCP9600 thermocouple EMF converter (SparkFun, SEN-16295), and an ESP32 microcontroller to capture the data (SparkFun, DEV-22924). A python notebook was used to process the saved data and perform statistical analysis using the SciPy statistical method libraries. One-way ANOVA and Tukey HSD(Honestly Significant Difference) were used to test for statistical differences. Results: One-way ANOVA on the down-pack and backfill units\u27 data showed significant differences. According to the Tukey HSD findings, there were no significant differences in the Woodpecker Backfill products for both max temperature and rate of heating. The max temperature showed strong similarity (p = 0.969), while the rate of heating showed a weaker significance (p = 0.073) but was still above threshold. All other backfill units performed statistically differently. The down-pack units all performed statistically different in both max temperature and rate of heating, except for the Elements IC and Woodpecker Fi-P units with respect to the rate of heating (p \u3e 0.05). Conclusions: Statistically different performance among the seven obturation groups was observed when investigating rise to temperature time and setpoint temperature. All materials were LSUHSC-owned equipment, donated, or purchased with internal funds