Journal of Nuclear Physics, Material Sciences, Radiation and Applications
Not a member yet
238 research outputs found
Sort by
Measurement of Content of 226Ra in Drinking Water From Some States of Mexican Republic by Liquid Scintillation Method
To assess the quality of drinking water in respect to the content of radioactivity, usually is carried out an screening program in the locations of interest, that program consist in pick representative samples of drinking water from the wells in that locations, water samples are analyzed to measuring the gross alpha/beta radioactivity by a low background proportional counter or a liquid scintillation system. When some sample exceeds the normative limit then it must be known which radionuclides are in that sample. Expected radionuclides in water are the NORM (normal occurring radioactive material) from the natural radioactive chains. 226Ra is frequently present in drinking water and is one of most important radionuclide because its “radiotoxicity”, the WHO [World Health Organization, Guidelines for drinking-water Quality, (2016)] recommends a reference level for 226Ra of 1 Bq/L (the dose coefficient for 226Ra is 2.8 x 10-7 Sv/Bq). From a national program of drinking water screening in the Mexican Republic, the samples that exceeded the national normative limits were picked again in the same well and analyzed by LS (liquid Scintillation), using the method of two phases with a not water miscible scintillator cocktail. Results of concentrations of 226Ra from drinking water are presented. In general the content of 226Ra in drinking water samples was lower that the guide values recommended for the WHO
Theoretical Study on the Formation of 1-neutron and 2-neutron Halo Nuclei via Decay of Elements in Super-Heavy Region
The possibility for the existence of 1-neutron and 2-neutron halo nuclei through the decay of even-even nuclei 270-316116, 272-318118 and 278-320120 in the super-heavy region is studied within the frame work of the Coulomb and Proximity Potential Model (CPPM). Halo structure in neutron rich nuclei with Z<=20 is identified by calculating the neutron separation energies and on the basis of potential energy considerations. The 1n + core configuration of proposed 1-neutron halo nuclei between z=10 and Z=20 is found shifted to 2n + core configuration in higher angular momentum states. The calculation of half-life of decay is performed by considering the proposed halo nuclei as spherical cluster and as deformed nuclei with a rms radius. Except for 15C, the half-life of decay is found decreased when the rms radius is considered. Only the 1-neutron halo nuclei 26F and 55Ca showed half-lives of decay which are less than the experimental limit. None of the proposed 2-neutron halo nuclei have shown a half-life of decay lower than the experimental limit. Also, the probability for the emission of neutron halo nuclei is found to be less in super-heavy region when compared with the clusters of same isotope family. Further, neutron shell closure at neutron numbers 150, 164 and 184 is identified form the plot of log10 T1/2 verses the neutron number of parents. The plots of Q-1/2 verses log10 T1/2 and -ln P verses log10 T1/2 for various halo nuclei emitted from the super-heavy elements are found to be linear showing that Geiger-Nuttall law is applicable to the emission of neutron halo also
Performance of PIXE Technique through a Geochemical Analysis of High Grade Rocks
It has been an argument that some of the elements present in geological material by using PIXE analysis are purely determined or could not be determined at all, due to various reasons including the matrix. It is felt that a systematic investigation needs to be designed and implemented to understand the limitation of PIXE in certain elements. The high-grade rocks selected are analyzed both by PIXE as well as AAS and the results are authenticated by using a USGS reference material, Basalt, studies of literature. It is believed that the accuracy of problematic elements, especially from high grade rock can be improved and the conditions of PIXE can be standardized for various elements under different combinations. The reasons behind the poor performance of Proton Induced X- ray Emission in case of certain elements have been established
Stability of Glycine in Saline Solutions Exposed to Ionizing Radiation
The stability of biologically important molecules, such as amino acids, being subjected to highradiation fields is relevant for chemical evolution studies. Bodies of water were very important in the primitive Earth. In these bodies, the presence of dissolved salts, together with organic molecules, could influence the behavior of the systems in prebiotic environments.The objective of this work is to examine the influence of sodium chloride on the stability of the amino acid glycine when subjected to high radiation doses. The analysis of the irradiated samples was followed by HPLC coupled with a UV-VIS detector. The results show that glycine in aqueous solutions (without oxygen) decomposed around 90% at a dose of 91 kGy. In the presence of salts, up to 80% of the amino acid was recovered at the same dose. Laboratory simulations demonstrate a protective role for sodium chloride (specifically the chloride ion) to glycine against an external source of ionizing radiation
Effects of Gamma Irradiation on Curcumin
In this study, remnants concentrations of curcumin in Curcuma longa (organic turmeric powder) were determined after it was exposed to irradiation doses of 1, 2 and 3 kGy. Curcumin analysis was performed using the analyte-sensitive impulse differential polarography technique (LOD: 0.621 ppm and LOQ: 2.130 ppm). The results obtained showed a decreasing concentration of curcumin as a function of the irradiation dose. This reduction is low in terms of affecting the product’s quality with respect to its concentration
Time Resolution Measurements on SiPM for High Energy Physics Experiments
Scintillator detector have been used in a wide range of experiments in different areas: Nuclear and High Energy Physics, Medicine, and Radiation Security among others. It is common to use scintillator counters coupled to Photomultiplier Tubes (PMT) as a read out detectors. Nowadays, there has been a great interest in using the Silicon Photomultipliers (PMSi) as a replacement for PMT's due to their high photon detection efficiency (PDE) and their high single photon time resolution (SPTR). The fast the signal is detected, the whole detection system will be useful to search for new physics. PMSi is also known to have a good compactness, magnetic field resistance and low cost. In our lab we are measuring the time resolution of two different models of PMS in order to build a fast radiation detector system
Behavior of Poly-A onto Kaolin
A combination of geochemical variables is necessary to explain the origin of life on Earth. Thus, in this work the sorption of Poly-A on a clay mineral (kaolinite) was studied to get an insight about the sorption capacity at different times and pH values, as well as to confirm the capabilities of the clay to protect the sorbate from an external source of ionizing radiation. Poly-A presented a high percentage of sorption in the clay, especially in acidic environments, and this percentage sharply decrease in alkaline media. On the other hand, Poly-A’s recovery was higher in the system with clay, confirming its protection role
Analysis of DDM into Gamma Radiation
We are interested in the purpose of a dipolar fermionic particle as a viable candidate of Dark Matter (DDM). Then, we study the annihilation of dark matter into photons, considering it as a neutral particle with non-vanishing magnetic (M) and electric (D) dipolar moments. The total annihilation cross section σ(χ → γ) is computed by starting from a general form of coupling χγ in a framework beyond to Standard Model (BSM). We found that candidates with O(mχ )∽102GeV, D≈10−16 e cm are required in order to satisfy the current cosmic relic density
Determination of Gamma-Ray Shielding Parameters for Concretes and Dosimeters Using MCNPX
Gamma-ray shielding parameter for some concretes and dosimeters having large scale applications in radiological protection are presented using MCNPX (version 2.4.0) at different energies. The MCNPX results are compared with experimental, MCNP and XCOM data, and good agreement is being noted. Present study indicates that MCNPX simulation method is suitable and reliable simulation tool to be used as an alternative method for the investigation of gamma-ray interaction. The present geometry can be used as standard geometry for MCNPX simulation for low- as well as high-Z materials
Spectrophotometric Study of Polymeric DyesGels After a Gamma Irradiation Process for its Possible Use as a Radiation Dosimeter
This work aims to evaluate a dosimetric system composed of green malachite supported in agarose. Previous work showed that solutions of green malachite irradiated at 1 to 40 kGy present a linear behavior. This system is a gel composed of green malachite (2.5×10–3 M), sodium benzoate (1%),and agarose (1%) that was exposed tovarious doses of gamma irradiation. The irradiated systems were measured with a UV-V is spectrophotometer at 619 nm. Experimental parameters (such as dose rate, doses, and temperature) were controlled and optimized for reproducible and reliable results. More studies are needed to propose a dosimeter in the system in the range of 1.8 to 4.0 kGy