Possible Alpha and 14C Cluster Emission From Hyper Radium Nuclei in The Mass Region A = 202-235
The possibilities for the emission of 4He and 14C clusters from hyper 202-235ΛRa are studied using our Coulomb and proximity potential model (CPPM) by including the lambda-nucleus potential. The predicted half lives show that hyper 202-231ΛRa nuclei are unstable against 4He emission and 14Cemission from 217- 229ΛRa are favorable for measurement. Our study also show that hyper Λ202235-Ra are stable against hyper Λ4He and Λ14C emission. The role of neutron shell closure (N = 126) in 213 ΛRn daughter and role of proton and neutron shell closure (Z = 82, N = 126) in Λ209Pb daughter are also revealed. As hyper nuclei decays to normal nuclei by mesonic/non-mesonic decay and since most of the predicted half lives for 4He and 14C emission from normal Ra nuclei are favorable for measurement, we presume that alpha and 14C cluster emission from hyper Ra nuclei can be detected in laboratory in a cascade (two-step) process
Atomic Multiplet and Charge Transfer Effects in the Resonant Inelastic X-Ray Scattering (RIXS) Spectra at the Nickel L2,3 Edge of NiF2
Resonant inelastic x-ray scattering (RIXS) is used to study the electronic structure of NiF2, which is the most ionic of the nickel compounds. RIXS can be viewed as a coherent two-steps process involving the absorption and the emission of x-rays. The soft x-ray absorption spectrum (XAS) at the metal L2,3 edge indicate the importance of atomic multiplet effects. RIXS spectra at L2,3 contain clearly defined emission peaks corresponding to d-excited states of Ni2+ at energies few eV below the elastic emission, which is strongly suppressed. These results are confirmed by atomic multiplet calculations using the Kramers-Heisenberg formula for RIXS processes. For larger energy losses, the emission spectra have a broad charge-transfer peak that results from the decay of hybridized Ni(3d)-F(2p) valence states. This is confirmed by comparison of the absorption and emission spectra recorded at the nickel L and fluorine K edges with F p and Ni d partial density of states using LDA + U calculations
Study of secondary muons detected within the tunnels of the Cholula pyramid
The pyramid of Cholula was built at the beginning of 100 B.C. and during of period of 500 years it was finished, had several new constructions, based on the previous constructions. The primarily material of construction is the adobe. Early in 1931 archaeological excavations began with the intention of exploring the interior of the pyramid, excavations were stopped in 1971, and to date no further excavations have been carried out. This work shows the first measurements of muons, particles that are very penetrating, these are generated by primary cosmic rays that was incoming in the atmosphere and these generates a rain of secondary particles, among them the muons. To measure this kind of particles was implemented a detector system, it is formed by a scintillator plastic coupled to a tube photomultiplier; the signals were acquired by mean of an oscilloscope. The detector was collocated near of the center of the pyramid; the location belongs to the maxima concentration in mass over the detector. Graphs of the charge distribution, maximum amplitude and characteristic rise times of the generated pulses in a plastic scintillator are shown, this is scintillator was synthesized in the materials laboratory of the FCFM-BUAP. In addition the optical characterization of the same was realized
Measurements of Neutrons In A Mixed GammaNeutron Field Using Three Different Types of Detectors
A linear electron accelerator for medical use is a device for the treatment of tumors by collimated beams of electrons and/or photons. These accelerators are devices that employ electromagnetic waves of high frequency, to accelerate electrons that are used directly in the treatment of superficial tumors, or, if they are made to hit them on an appropriate target, they can produce photons of high energy destined to the treatment of deeptumors.Depending on the energy of the electrons and photons and the materials that make up the head of the accelerator and the target, this equipment will produce in addition to the aforementioned radiation, neutron fields of regular intensity. It is necessary to estimate the equivalent dose due to the neutrons themselves, the doses due to the gamma field of neutron capture, produced by the capture of thermal neutrons in the concrete of the bunker, and the gamma doses due to phenomena of neutron activation of elements of the own accelerator.
It is therefore important to be able to measure (detect, quantify, dose, etc.) both photons and neutrons in these cases and others more. In this work we use three different detectors, namely a scintillator-photomultiplier system, a fast reading dosimeter and bubble detector. The idea is to measure the radiation separately and compare their results.
The results obtained were the mixed gamma-neutron field spectrum, the dose due only to neutrons obtained by the bubble detectors, which is compared to the dose obtained by the second fast reading dosimeters (model 884), plus the dose obtained by the first dosimeters (model 609) and finally the dose obtained by the Victoreen dosimeter
Xps Study of the Oxidation State of Uranium Dioxide
In this article we report an investigation of the oxidation state of uranium dioxide using X-Ray Photoelectron Spectroscopy, and by comparing to results obtained in previous studies. We find that uranium dioxide in powder appears to share its six valence electrons with the oxygen atoms to form crystalline UO3
Radiation Induced Oxidation Reactions of Ferrous Ions: An Agent-based Model
Chemical Fricke dosimeter in the laboratory can be submitted to gamma radiation at low temperatures to study the evolution of oxidation reactions induced by radiation, a key process to understand the formation of complex molecules. Products generated by the interaction of the different elements under radiation can be determined through a mathematical model that considers chemical reactions as coupled nonlinear ordinary differential equations involving the mass balance of all the species in the reaction. In this paper is implemented an alternative way of solving this system of equations, species’ concentrations are calculated through an agent-based model implemented in Python. The model is a modified version of the prey-predator model where each chemical specie involved is considered as an agent that can interact with other specie with known reaction rates leading to production (source terms) and to destruction (sink terms). Here, the radiation is a factor that affects product formation while the bath temperature modifies the reaction speed. This model can reproduce experimental concentrations of products and the consumption of ferrous ions from a laboratory reaction of irradiation of iron salt solutions at 3 different temperatures (dry ice, liquid nitrogen, and room temperature)
Influence of Mo6+ on Dielectric properties of Copper Ferrites
Two series of copper ferrites are prepared using the chemical compositional formula Cu1.0-3y Fe2.0-2x Mox + yO4.0. They are calcinated at 750 C and sintered at 950C.When x =y = 0.0, the ε′ of the basic copper ferrite is probably due to electronic exchange interactions of copper and iron ions as Cu2+↔ Cu1+ and Fe3+↔ Fe2+. The observed value of dielectric constant (є′) decreases as a function of substituent concentration (x) up to x = 0.20 and for further values of ‘x’ it found to increase. In the case of ‘C’ (x = 0) series ferrites є′ decreases with substituent concentration (y) up to y = 0.04, later it found to increase. The dispersion of ac resistivity with frequency is observed indicating their strong dependence on frequency as in the case of dielectric behaviour. These results are explained with different possible mechanisms
The Dependence of Surface Diffuseness Parameter on N/Z Ratio of The Fusion of Neutron-Rich Colliding Nuclei
Surface diffuseness parameter used in Woods-Saxon form of potential have been extracted from a large number of experimentally studied neutron-rich fusion cross sections at near barrier energies. The results of our systematic study reveals that the extracted diffuseness parameter depend linearly on the N/Z ratio of the fusing nuclei. Further, we demonstrated that the extracted values of surface diffuseness parameter lies within the range a = 0.40 to 0.73 fm as compared to commonly accepted value form elastic scattering data i.e. 0.63 fm
Characterization of Structures of Equivalent Tissue With a Pixel Detector
Research using hybrid pixel detectors in medical physics is on the rise. Timepix detectors have arrays of 256 × 256 pixels with a resolution of 55 μm. Here, and by using Timepix counts instead of Hounsfield units, we present a calibration curve of a Timepix detector analog to those used for CT calibration. Experimentation consisted of the characterization of electron density in 10 different kinds of tissue equivalent samples from a CIRS 062M phantom (lung, 3 kinds of bones, fat, breast, muscle, water and air). Radiation of the detector was performed using an orthodontic X-ray machine at 70 KeV and .06 second of tube current with a purpose-built aluminum collimator. Data acquisition was performed at 1 frame per second and taking 3 frames per phantom. We were able to find a curve whose behavior was similar to others already published. This will lead to the verification of the usage of Timepix for identification of different tissues in an organ
Application of a CdTe Detector for Measurements of Mammographic X-ray Spectra
This work aims to characterize mammographic x-ray beams incident and transmitted by breast phantoms (from 0 to 45 mm) composed from known proportion of glandular and adipose tissue-equivalent materials. This study was performed for mammographic x-ray beams generated by a mammography equipment using different target/filter combinations (Mo/Mo, Mo/Rh and W/Rh). It was studied the modification of spectra shape of the beams transmitted through different thicknesses of these materials. It was also evaluated the penetrability of these transmitted beams by its correlations to the HVL, which were experimentally estimated and derived from the x-ray spectra measured using a spectrometry system with a CdTe detector. The x-ray spectra transmitted by the phantom with higher density presented lower intensity than those transmitted by those with lower density, as expected. The differences between the HVL values derived from the spectra and those estimated using air kerma measurements are lesser than 6% for about 88% of the spectra measured in this work. The expected spectra variations with phantom thickness, revealed by the measured transmitted x-ray spectra, were also confirmed by HVL measurements and agree with the estimated attenuation curves.The motivation of the study was related to the robustness of the spectra as a descriptor of radiation beams and the possibility of using these transmitted spectra for dose assessment related to mammographic procedures. We can conclude that developed method is able to characterize mammographic x-ray beams making it possible the use of this kind of data for dose assessment in mammography