SICOT-J - Société Internationale de Chirurgie Orthopédique et de Traumatologie
Not a member yet
578 research outputs found
Sort by
Radiographic parameters and a novel fluoroscopic control view for posterior screw fixation of coracoid base fractures
Introduction: Coracoid fractures have the potential to lead to inadequate shoulder function. Most coracoid base fractures occur with scapular fractures and the posterior approaches would be utilized for surgical treatment. We investigated the possibility of fixing the coracoid through the same approach without an additional anterior approach. Materials and methods: Multi-slice CT scans of 30 shoulders were examined and the following measurements were performed by an independent specialized radiologist: posterior coracoid screw entry point measured form infraglenoid tubercle, screw trajectory in coronal plane in relation to scapular spine and lateral scapular border, screw trajectory in sagittal plane in relation to glenoid face bisector line and screw length. We used the results from the CT study to guide postero-anterior coracoid screw insertion under fluoroscopic guidance on two fresh frozen cadaveric specimens to assess the reproducibility of accurate screw placement based on these parameters. We also developed a novel fluoroscopic projection, the anteroposterior (AP) coracoid view, to guide screw placement in the para-coronal plane. Results: The mean distance between entry point and the infraglenoid tubercle was 10.8 mm (range: 9.2–13.9, SD 1.36). The mean screw length was 52 mm (range: 46.7–58.5, SD 3.3). The mean sagittal inclination angle between was 44.7 degrees (range: 25–59, SD 5.8). The mean angle between screw line and lateral scapular border was 47.9 degrees (range: 34–58, SD 4.3). The mean angle between screw line and scapular spine was 86.2 degrees (range: 75–95, SD 4.9). It was easy to reproduce the screw trajectory in the para-coronal plane; however, multiple attempts were needed to reach the correct angle in the parasagittal plane, requiring several C-arm corrections. Conclusion: This study facilitates posterior fixation of coracoid process fractures and will inform the “virtual visualization” of coracoid process orientation
Antegrade anterior column screw placement in the lateral decubitus position utilizing an axial view: a technical trick
The placement of anterior column screws is a useful procedure and has standard views when placing this screw in the supine position. Feng et al. described an acetabular anterior column axial view for patients in the supine position for a placement of a retrograde anterior column screw [J Orthop Surg (Hong Kong) 25, 2309499016685012]. However, many acetabular fracture surgeries are performed in the lateral decubitus position due to a variety of reasons. Placing an antegrade anterior column screw in this position is difficult due to an unfamiliarity of the optimal fluoroscopic images. The purpose of this article is to describe a novel technique to obtain appropriate imaging to safely place an anterior column screw while the patient is in the lateral decubitus position
Current concepts in robotic total hip arthroplasty
Introduction: Total hip replacement provides mostly fair functional and clinical results. Many factors play an essential role in hip stability and long-term outcomes. Surgical positioning remains fundamental for obtaining accurate implant fit and prevent hip dislocation or impingement. Different categories of robotic assistance have been established throughout the previous years and all of the technologies target accuracy and reliability to reduce complications, and enhance clinical outcomes. Materials and methods: An overview is proposed over the principles of robotic assistance in hip arthroplasty surgery. Accuracy, reliability, management of the bone stock, clinical outcomes, constraints and limits of this technology are reported, based on recent literature. Results: Potential advantages regarding pre-operative planning accuracy, cup positioning, maintenance of the center of rotation, preservation of an adequate bone stock nay clinical short- and mid-term outcomes are balanced with some reported disadvantages and limits like hip anatomical specificity, cost-effectiveness, engineering dependence. Discussion: The use of robotic-assisted THA presents clear and evident benefits related to accurate implant positioning and maintenance of a minimal bone while allowing. For some authors, an early improvement in functional results and patient’s recovery. This technology demonstrated a shorter surgical time and a short learning curve required to optimize its use and this technology presents promising outcomes and results and potential use in routine clinical application but its limitation of use is still present especially the cost of the robot, the need for the presence of an engineer during the surgery, its availability of use in all hospitals as well as the difficulty presented in dysplastic or dysmorphic hip joints
Two cases of deliberate implant mismatch in knee arthroplasty
Cases: Knee arthroplasty is increasingly common with good clinical results. However, there is a cohort of patients whose native knee anatomy may not marry well with standard implants. The current authors describe two cases (one unicompartmental knee arthroplasty (UKA), one total knee arthroplasty (TKA)), during which deliberately implanting an implant designed for the contra-lateral distal femur (TKA) or contralateral femoral condyle (UKA) respectively, led to a better fit than correct-sided implants. Conclusion: The authors share their experience to raise awareness of a potential solution to such an intra-operative challenge and suggest that implant customisation may ultimately address challenges with grossly abnormal native anatomy
Giant intrathoracic ganglioneuroma with scoliosis treated by one-stage posterior resection and scoliosis correction: a case report
Spinal ganglioneuroma occurs mostly in the thoracic spine causing various manifestations including scoliosis that can be misdiagnosed as idiopathic scoliosis. Few reports exist in the literature on the diagnosis and management of scoliosis secondary to huge ganglioneuroma and usually staged treatment is preferred. In this report, we present a 17-year-old female patient presented with back pain, lower limbs numbness, spinal deformity, and shortness of breath. Plain X-rays showed a 50° right thoracic scoliotic curve. MRI and chest CT revealed a huge extra pulmonary mass shifting the mediastinum with intra spinal extension through the left neural foramina compressing the spinal cord. Percutaneous US guided needle biopsy confirmed the diagnosis of ganglioneuroma. One-stage posterior instrumented correction of scoliosis, spinal cord decompression, and excision of the whole mass from the mediastinum and the spine through posterior approach was done for the patient with smooth postoperative recovery. Chest CT scan was done 2 years after surgery and excluded any local recurrence
Dual mobility cups for total hip arthroplasty: tips and tricks
Since its creation in 1974, the Dual Mobility Cup (DMC) has been gaining in popularity, especially in the past decade. This intensive use could lead to inappropriate use and consequently to an increased complication rate. Compliance with conceptual requirements and surgical techniques will prevent the occurrence of complications that can be wrongly attributed to implants. In this context, we feel that it is essential to share our tips and tricks as well as an overview and an explanation of common errors, based on more than 45 years of clinical and research experience. From basic principles, including indications, implant choice and implant compatibility, to surgical tips, in this article orthopedic surgeons will find a practical overview of DMC in order to use it safely and with confidence
Early outcome after the use of the triceps fascia flap in interposition elbow arthroplasty: a novel method in the treatment of post-traumatic elbow stiffness
Background: Post-traumatic elbow stiffness (PTES) results in severe interference with the activities of daily living (ADL), affecting mainly young people. Total elbow arthroplasty (TEA) is relatively contraindicated in the young patient and arthrodesis is poorly tolerated. Interposition elbow arthroplasty (IEA) improves the range of motion (ROM) buying time for future reconstructive surgery. While the fascia lata remains the most common material used in IEA, the triceps fascia is a native vascularized tissue, and it does not require a separate incision to harvest. To our knowledge, there are no published studies on the use of this technique of IEA. Method: Sixteen patients with post-traumatic elbow stiffness had IEA with the triceps fascia between January 2009 and January 2017. The ROM was assessed pre-operatively and post-operatively at the 6th and the 24th week. The researchers also evaluated the functional outcome with the Mayo Elbow Performance Score (MEPS) at the 24th week. The data were analysed with the software IBM SPSS Version 20. Results: Nine males and seven females had IEA with the triceps fascia. The mean age of the subjects was 22.8 years (SD = 6.39). The median duration of the stiffness was eight months (range: 2–168 months). Fall was the most frequent cause of post-traumatic elbow stiffness, and the non-dominant side was more frequently involved. Fourteen patients had an intervention at the native bone setters before presentation to the hospital. The mean elbow ROM increased from 16.4° pre-operatively to 97.2° at the 24th week (p < 0.001), while the mean MEPS improved from 42.5° pre-operatively to 81.2° post-operatively (p < 0.001). Conclusion: The triceps fascia flap provides an excellent alternative to the fascia lata for IEA without the complications of the donor site morbidity
A rare cause of sciatica: Sciatic nerve schwannoma
The authors report one case of schwannoma located in the sciatic nerve, just above the popliteal fossa. A sciatic localization is rare, observed in 1% of the patients. The misleading clinical presentation of this localization causes a delay in diagnosis. Magnetic Resonance Imaging (MRI) is the imaging modality of choice, but the final diagnosis is made by the histological examination of the tumor. Schwannoma should be surgically removed without division of the nerve trunk
Recent update on crosslinked polyethylene in total hip arthroplasty
More than two decades after their clinical introduction, crosslinked polyethylenes (XLPE) have been widely adopted. Though concerns were initially raised regarding oxidation and brittleness, on a large scale, the first generation of XLPE continues to be highly effective 15 years after the surgery, even in a young and active population. Remelted XLPE might display lower wear rates than annealed XLPE. Second generation XLPEs, not only including sequentially irradiated and annealed but also associated with antioxidants, demonstrate encouraging short- to mid-term results. Registry data support clinical trial reports. Even in less favorable settings (lipped liners, dual mobility cups, revision surgery, hip resurfacing) results are promising. However, failures (fractures) have already been described. Therefore, a high level of surveillance remains crucial