Wrocław University of Science and Technology
Repozytorium Eny Politechnika WrocławskaNot a member yet
431 research outputs found
Sort by
1998 IEEE Approved Indexing Keyword List
1998 IEEE Approved Indexing Keyword List (c) 1998 Institute of Electrical and Electronics Engineers = Note: * Keywords preceded by an asterisk (*) should not be used. Instead, use one of the choices indicated
Classification of Electric Signals Based on Time-Frequency Signal Decomposition
A classification procedure based on time-frequency decomposition of the signal is presented. Parametric spectral ESPRIT method is used for estimation of relevant parameters of signal components and specific areas of the time-frequency plane are chosen, where the signal is expected to show most characteristic patterns. Classification is based on time-domain correlation of reconstructed signals. It is applied to event classification of non-stationary electric signals obtained from a simulated power converter
Digital Methods for on-line Estimation of the Basic Components of Signals in Electrical Power Systems
The fast determination of the Symetrical Components of voltages and currents in three-phase systems is very important for the analysis of faults and protection tasks. Digital algorithms for real-time estimation of the positive-sequence component after faults are investigated, using the Fourier- and Kalman filter theory
Inactivation of Yersinia enterocolitica Gram-negative bacteria using high voltage technique
High voltage pulses of peak voltages U=5-75 kV and rise times tp=500-1300 ns were applied with repetition frequency f=lHz in order to cause the irreversible electroporation of Gram negative bacteria Yersinia enterocolitica. The bacteria were suspended in NaCl solution of pH=7.2 and conductivity y ~0.8-1.3 S/m. The suspension was placed in glass tube immersed in the cylindrical electrode system gap filled with distilled water. Such an electrode system will protect the bacteria suspension from the chemical processes at the electrode-liquid interface due to conduction and pre-breakdown phenomena. The current chopping electrode system was connected in parallel to the sample in order to avoid heat generation from direct discharge of the pulse through the suspension. The dependence of the survival ratio s=N/No (the number of bacteria per cm3 after pulse treatment, N, divided by the number of bacteria per cm3 before treatment, NJ of Y. enterocolitica on peak voltage of the pulse, number of pulses applied and on various rise times of pulses have been measured. The reduction by 6 orders of magnitude of Y. enterocolitica living cells per cm3 was achieved. The results show that considerable inactivation of microbes can be achieved by the application of short (tp 4000 ns) high voltage pulses for bacteria suspension without directly exposing the bacteria suspension to the electrodes. It is therefore possible to use the electrode system proposed as a means for sterilization of liquid foods
Kinetic Model of Carrier Recombination in Solid Dielectric
In this paper the model of solid dielectric is presented, in which the space-charge is formed by free and trapped electrons, as well as by holes. Charge transport is described by means of the Gauss law, the continuity equation and the system of equations describing the contribution of electron localization and delocalization states in the generation-recombination processes. It is assumed that initial values of carrier concentration are equal to the values of equilibrium concentration Boundary values of free carriers concentration are established basing on mechanisms of carriers injection from metal into the dielectric. The influence of generation-recombination processes and of mechanisms of injection on the time-course of absorption current density are also determined, the latter being evaluated numerically
Wpływ udarów prądowych na zjawiska starzeniowe w ceramice warystorowej.
W artykule przedstawiono wpływ impulsów prądowych na właściwości elektryczne warystorów ZnO. Zjawiska starzeniowe badano metodą analizy odpowiedzi dielektrycznej w zakresie częstotliwości od 40 Hz do 10 MHz. Abstract. (The influence of current impulses on degradation phenomena in varistor ceramic). This paper presents the effect of impulse current on the electrical properties of ZnO varistor The degradation phenomena were investigated by using of analysis of the dielectric response in the frequency range from 40 Hz to 10 MHz
Metoda określenia wartości parametrów wewnętrznych modelu warystora na podstawie pomiaru wartości chwilowych prądu i napięcia
Beziskiernikowe ograniczniki przepięć, których aktywną część stanowią warystory oparte na tlenku cynku, spełniają coraz powszechniej rolę układów ochrony izolacji urządzeń elektroenergetycznych. Szczególnie istotny stał się więc problem oceny stanu funkcjonalnego warystorów. Z tego względu szczególnie interesujące jest określenie schematu zastępczego warystora ZnO i jego parametrów. Abstract. (Method of varistor model internal parameters determination using measured values of current and voltage). The ZnO varistors are widely used as devices for overvoltage protection. There is need for a method of voltage load capacity assessment. In this paper the method of varistor equivalent circuit diagram parameters estimation is proposed
Impact of Secondary Burden and X/R Ratio on CT Saturation
Proper selection of a CT (Current Transducer) is required for a good protection scheme operation. Among many other factors which can affect the current measurements accuracy this paper only investigates two of them i.e.: X/R ratio of the primary fault path and secondary burden of a CT. The importance of taking this two parameters under consideration is shown
Systemy zabezpieczeń budynków wielkokubaturowych
Współczesne czasy gdzie priorytetem jest życie i zdrowie ludzkie sprawiają iż duży nacisk kładzie się na rozwój oraz tworzenie nowych systemów mających zapewnić jak największą ochronę i bezpieczeństwo ludzi. Budynki o wielkiej kubaturze takie jak centra handlowe, kina, teatry, szkoły, hotele, restauracje w których jednocześnie przebywa często po kilkaset osób mogą stanąć w obliczu wszelakich zagrożeń. Jednym z nich i bardzo niebezpiecznym jest ogień. Mimo dużej świadomości społeczeństwa o tym żywiole prawdopodobieństwo wystąpienia pożaru występuje zawsze. Wystarczy często niedopałek papierosa lub iskra z uszkodzonej instalacji elektrycznej, przegrzany silnik. Szkody wynikłe z wystąpienia pożaru to głównie straty materialne oraz zagrożenie dla ludzkiego życia. Aby zapobiec tego rodzaju zagrożeniom stosowane są nowoczesne systemy. Podstawowe z nich to: · system sygnalizacji pożaru; · dźwiękowy system ostrzegawczy. Oprócz pożaru mamy również do czynienia z innego typu niebezpieczeństwami, na które narażeni są ludzie przebywający w budynkach. Dość realnym w dzisiejszych czasach i jednocześnie jednym z najbardziej niebezpiecznych jest zagrożenie atakiem terrorystycznym. Z myślą o takim charakterze niebezpieczeństwa powstały system ochrony mienia mające zabezpieczyć przed wtargnięciem niepożądanych osób. Systemy te to : · Kontrola dostępu; · System sygnalizacji włamania i napadu; · Telewizja przemysłowa. Zastosowanie tych systemów w budynkach nie daje 100% pewności bezpieczeństwa lecz do minimum obniża mogące wystąpić zagrożenie