Wrocław University of Science and Technology

Repozytorium Eny Politechnika Wrocławska
Not a member yet
    431 research outputs found

    Advanced spectral analysis of out-of-step operation of synchronous machines

    Full text link
    The out-of-step operation conditions of a synchronous machine may occur as a result of a power system three-phase fault. The mostly used methods of identification of loss of synchronism are not secure enough. In the paper a new method using high-resolution spectrum estimation method is presented. In the case of asynchronous operation of a synchronous machine the current waveform in the stator winding can be resolved into three components, which frequencies differ insignificantly. High-resolution subspace methods enable to estimate the frequencies and on this way to identify the asynchronous operation. Copyright © 2003 IFA

    Wzorzec stratności dielektrycznej przy niskich częstotliwościach

    Full text link
    Wzorcowanie mierników pojemności elektrycznej C i współczynnika tg delta, stosowanych do pomiarów przenikalności elektrycznej i współczynnika stratności dielektrycznej, jest utrudnione przez brak odpowiednio dokładnych wzorców tg d. Wzorce tg d realizuje się poprzez szeregowe połączenie kondensatora z rezystorem o znanej wartości. Zasadniczą przyczyną niedokładności takiego wzorca są głównie parametry resztkowe rezystora. Opisany w tym artykule wzorzec tgd przy 50 Hz ma zakres pomiarowy (0,1÷10)×10-4 i niepewność wartości 10-5.============.Calibration of electric capacitance C and the tgd factor of meters, used for permittivity and dielectric dissipation factor tgd measurements, is difficult as there is no adequately accurate tgd standards. Dielectric dissipation factor standards are made of series connection of known value capacitor and resistor. Main reason of inaccuracy this type of standard are mainly residual parameters of resistor. The standard tgd described in this paper has at 50 Hz the range (0.1÷10)×10-4 and uncertainty of value 10-5

    Termowizyjne badania generatorów prądotwórczych

    Full text link
    Zagadnienie promieniowania podczerwonego, technik termograficznych, metody pomiarów nadal często są nowością dla osób, które będą wykorzystywać kamery termowizyjne. W pracy tej przedstawiono teorię termografii, sposoby pomiarów kamerami termowizyjnymi, omówienie problematyki związanej z rejestrowaniem i interpretacją wyników, opisy najczęściej występujących problemów, zjawiska mające wpływ na wyniki pomiaru. Szczegółowo opracowano zagadnienia badania elementów generatorów prądotwórczych dużej mocy. 2. Zakres pracy. W części teoretycznej zawarto wiele podstawowych wiadomości dotyczących sposobów pomiaru temperatury, opisano Międzynarodową Skali temperatury 1990 (MTS-90) oraz zestawiono różne skale temperatur wykorzystywanych w praktyce pomiarowej (rozdz.3.1.). Wyjaśniono także pojęcia i skróty charakterystyczne dla dziedziny termografii (rozdz. 3.2.). W ujęto również historię techniki podczerwieni (rozdz. 3.3.) oraz praw wykorzystywanych podczas pomiarów termowizyjnych (rozdz.3.4.). Rozdział 3.5. poświęcony został podstawom pomiarów za pomocą kamery termowizyjnej. Zawarto w nim opisy zjawisk pozwalających na zdalny pomiar temperatury oraz wpływ otoczenia na przebieg pomiarów. Umieszczono również w tej części wskazówki pozwalające na dobór odpowiednich wartości emisyjności dla danego badanego obiektu. W następnym rozdziale (rozdz. 3.6.) omówiono kamerę, która jest głównym elementem pozwalającym na rejestrowanie rozkładu temperatur, jej budowę, sposób działania, podstawowe parametry. Dokonano także przeglądu urządzeń termowizyjnych oraz oprogramowania pozwalającego na obróbkę i interpretację danych pochodzących z kamer. Kolejna część pracy poświęcona została praktycznej stronie pomiarów, uwzględnia problemy powstałe podczas badań i interpretacje wyników. Rozdział 4.1. ukazuje wszechstronne zastosowanie badań termowizyjnych i wykorzystywanie ich przy rozwoju poszczególnych dziedzin począwszy od przemysłu a skończywszy na medycynie. Informacje tu zamieszczone to jedynie przykłady, jedne z wielu do których wykorzystywana jest termowizja. Pomiary, termogramy i interpretacje wyników, które zamieszczono w rozdziale 4.2 dotyczą elementów i podzespołów generatorów prądotwórczych dużej mocy. Badania wykonano kamerą termowizyjną firmy Flir, model ThermaCAM P65. Prace pomiarowe dokonywano pod nadzorem i za zgodą ALSTOM POWER Sp. z o.o. W ostatnim etapie pracy zestawiono otrzymane wyniki, zlokalizowano usterki, dokonano ponownych pomiarów naprawianych miejsc, określono wady i zalety metod pomiarowych, wynotowano czynniki mające wpływ na wyniki pomiarów oraz sformułowano wnioski

    Power Quality Events

    Full text link
    Lecture "Power Quality Events

    Harmonics - Power Quality

    No full text
    Lecture "Harmonic - Power Quality

    Probabilistic Analysis of Voltage Deviations in the Distribution Network with Small Synchronous Generators

    Full text link
    Fulfilling voltage quality requirements may produce the bottleneck of sending the whole local generation to the medium voltage network. Voltage regulation at the transformer on-load tap changer and small synchronous generators can be simultaneously used for voltage control in the distribution network. To achieve proper results the randomness of active and reactive node loads should be taken into consideration. Solving such problems is the goal of paper. Mathematical background and results of simulations are presented

    Pomiar impedancji z wykorzystaniem algorytmu adaptacyjnego

    Full text link
    Pomiary impedancji wymagają stabilnej częstotliwości pomiarowej. Jednym ze sposobów ograniczenia tego problemu jest algorytm który nadąża za zmianami częstotliwości źródła. Wykorzystano zjawisko tzw. przecieku widma DFT sygnału próbkowanego. Przedstawiono algorytm realizujący opisaną metodę i jego implementację w pakiecie z procesorem sygnałowym. Wykonano pomiary testujące oraz omówiono wpływ wybranych czynników na błędy pomiaru

    Lightning impulse performance of polluted medium voltage insulators

    Full text link
    The concentrated dry bands on many silicone rubber insulators and also on porcelain insulators were observed by means of termovision camera. The lightning impulse flashover voltage on clean and polluted traction insulators was measured. The solid layer or flow-on layer were applied. The solid layer was wetted by moisture absorption from very humid air. At the same value of ESDD the flashover voltage was smaller on insulators polluted by the solid layer. This effect is unexpected because at the same ESDD value the solid layer surface conductivity is smaller than the surface conductivity of the flow-on layer. The phenomenon could be explained by an easier and quicker arc propagation over the solid layer

    Effect of impulse polarity on the flashover voltage of polluted cap and pin insulators

    Full text link
    The lightning impulse flashover voltage on clean and polluted cap and pin insulators under high humidity conditions were measured. It was shown that the negative flashover voltage of non-uniformly polluted insulators is about 15% lower than the positive one. Bigger difference of over 25% was found on a model insulator. The electrical strength of disc insulators lightly polluted on the upper part of the shed and heavily polluted under shed can be twice lower than that of clean insulators

    Effect of silicone rubber insulators' profiles on their ageing performance in rain conditions

    Full text link
    Numerous studies have been conducted to understand the effect of insulator profiles on ceramic insulators, whereas for polymer insulators this problem has not sufficiently examined. The research so far has concentrated on material composition. The new investigations into influence of the shape of composite insulators with silicone rubber housings have dealt only-with ageing performance in fog conditions. Rains constitute a major ageing stress for composite insulators. They can wash out low molecular weight components from the surface of silicone rubber, which may lead to loss of hydrophobicity by the insulator surface, increase leakage currents, the development of surface discharges and in consequence, the development of ageing processes. This paper presents investigations into ageing processes of model composite insulators in high-voltage artificial rain chamber. The same housing material — silicone rubber (HTV) — was used to manufacture, the model insulators. The results of the investigations have shown a clear influence of the silicone rubber insulators' profiles on their ageing performance in rain conditions

    332

    full texts

    431

    metadata records
    Updated in last 30 days.
    Repozytorium Eny Politechnika Wrocławska
    Access Repository Dashboard