Walter Sisulu University
Not a member yet
1284 research outputs found
Sort by
Selecting human papillomavirus genotypes to optimize the performance of screening tests among South African women
On the Derivation of Nonclassical Symmetries of the Black–Scholes Equation via an Equivalence Transformation
Data on microhardness and structural analysis of friction stir spot welded lap joints of AA5083-H116
Successful use of an improvised bubble CPAP device for severe respiratory distress caused by pulmonary tuberculosis
Epidemiology, risk factors and molecular analysis of carbapenem-resistant Enterobacteriaceae (CRE) in Mthatha, Eastern Cape, South Africa
Patient acceptance of HIV testing services in rural emergency departments in South Africa
Background: South Africa faces the highest burden of HIV infection globally. The National Strategic Plan on HIV recommends provider-initiated HIV counselling and testing (HCT) in all healthcare facilities. However, HIV continues to overwhelm the healthcare system. Emergency department (ED)-based HCT could address unmet testing needs. Objectives: This study examines the reasons for accepting or declining HCT in South African EDs to inform the development of HCT implementation strategies. Method: We conducted a prospective observational study in two rural EDs, from June to September 2017. Patients presenting to the ED were systematically approached and offered a point-of-care test in accordance with national guidelines. Patients demographics, presenting compaint, medical history and reasons for accepting/declining testing, were recorded. A pooled analysis is presented. Results: Across sites, 2074 adult, non-critical patients in the ED were approached; 1880 were enrolled in the study. Of those enrolled, 19.7% had a previously known positive diagnosis, and 80.3% were unaware of their HIV status. Of those unaware, 90% patients accepted and 10% declined testing. The primary reasons for declining testing were ‘does not want to know status’ (37.6%), ‘in too much pain’ (34%) and ‘does not believe they are at risk’ (19.9%). Conclusions: Despite national guidelines, a high proportion of individuals remain undiagnosed, of which a majority are young men. Our study demonstrated high patient acceptance of ED-based HCT. There is a need for investment and innovation regarding effective pain management and confidential service delivery to address patient barriers. Findings support a routine, non-targeted HCT strategy in EDs. Keywords: HIV counselling and testing; South Africa; emergency department; patient acceptance; implementation research; linkage to care
Data on microhardness and structural analysis of friction stir spot welded lap joints of AA5083-H116
Friction stir spot welding (FSSW) was established to compete reasonably with the reverting, bolting, adhesive bonding as well as resistance spot welding (RSW) which have been used in the past for lap joining in automobile, aerospace, marine, railways, defence and shipbuilding industries. The use of these ancient and conventional joining techniques had led to increasing material cost, installation labour, and additional weight in the aircraft, shipbuilding, and other areas of applications. All these are disadvantages that can be overcome using FSSW. This research work carried out friction stir spot welding on 5058-H116 aluminium alloy by employing rotational speed in the step of 300 rpm ranges from 600 rpm to 1200 rpm with a no travel speed. It was noted that the dwell times were in the step of 5 s varying from 5 s to 15 s while the tool plunge rate was maintained at 30 mm/min. In this dataset, a cylindrical tapered rotating H13 Hot-working steel tool was used with a probe length of 5 mm and probe diameter of 6 mm, it has a shoulder diameter of 18 mm. The tool penetration depth (plunge) was maintained at 0.2 mm and the tool tilt angle at 2°. Structural integrity was car-ried out using Rigaku ultima IV multifunctional X-ray diffractometer (XRD) with a scan voltage of 40 kV and scan current of 30 mA. This was used to determine crystallite sizes, peak intensity, d-spacing, full width at half maximum intensity (FWHM) of the diffraction peak. TH713 digital microhardness equipment with diamond indenter was used for microhardness data acquisition following ASTM E92–82 standard test. The average Vickers hardness data values at different zones of the spot-welds were captured and presented
Dataset of experimental and adaptive neuro-fuzzy inference system (ANFIS) model prediction of R600a/MWCNT nanolubricant in a vapour compression system
This research paper assessed the performance of R600a with the base lubricant and Multi-walled Carbon Nanotube (MWCNT) nanolubricant at steady state. It describes the instruments required for measurement of the data parameter and its uncertainties, steps involved in preparing and replacing the MWCNT nanolubricant concentration with base lubricant in vapour compression refrigeration. The system’s temperature data was collected at the components inlets and outlets. Pressure data was also registered at the compressor outlet and inlet. The data was captured at 27 °C ambient temperature at an interval of 30 min for 300 min. The experiment includes the experimental data collection, Adaptive Neuro-Fuzzy Inference System (ANFIS) training and testing dataset. The use of ANFIS model is explained in predicting the efficiency of MWCNT nanolubricant in a vapour compression refrigerator system. The ANFIS model also provides statistical output measures such as Root Mean Square Error (RMSE) and Mean Absolute Deviation (MAD), Mean Absolute Percentage Error (MAPE), and determination coefficient (R2). The data is useful and important for replacing MWCNT nanolubricant with base lubricant in a vapour compression refrigeration system for researchers in the specialisation of energy-efficient materials in refrigeration. The data present can be reused for vapour compression refrigeration systems simulation and modelling