Physikalisch-Technische Bundesanstalt

Open Access Repository of the Physikalisch-Technische Bundesanstalt (PTB-OAR)
Not a member yet
    1101 research outputs found

    D4: Good Practice Guide on sample processing, treatment, uncertainty budgets, and the quantification of the so-called mass bias

    No full text
    This Good Practice Guide has been structured around the specific objectives and needs of the MetroPOEM project, namely to develop isotope ratio mass spectrometric methods for stable and long-lived radiogenic environmental pollutants, to produce recommendations for sample processing, treatment, uncertainty budgets, and quantification of instrumental mass bias, and the need for obtaining SI-traceable isotope amount ratios. The guide has reviewed and summarised the existing approaches to sample preparation and calibration of isotope ratio measurements. Continued progress made in evaluating and modelling instrumental isotope fractionation in ICP-based mass spectrometers, with recommendations for setting up high precision measurement protocols, are articulated in the section on correction for instrumental isotope fractionation. Separate sections on best practices for reporting results of isotope ratio measurements and constructing uncertainty budgets are also included. The information presented should help an analyst to make an informed choice on suitable measurement strategy in the isotopic characterisation of materials. It is also anticipated that the present guide will help enhance awareness of the need for improving data comparability between different laboratories and support the community`s need for reliable isotope ratio data

    The CCRI Task Group on the Use of Mass Spectrometry in Radionuclide Metrology

    No full text
    The CCRI(II) has formed a new Task Group to support the increasing use of mass spectrometry in radionuclide measurement applications across areas including nuclear decommissioning, environmental monitoring, and nuclear forensics. The Task Group is exploring current and potential roles for mass spectrometry in radionuclide metrology, including the identification of priority radionuclides, development of methods, instrumentation, standards, and relevant reference materials, as well as identifying the best approaches for the exchange of information. Collaborations with other communities are establishing where radionuclide measurement by mass spectrometry can add value, including earth and climate science, food safety, environmental monitoring, and emergency response

    CHF3 infrared absorption cross sections

    No full text
    This dataset is generated from two composite infrared absorption cross section spectra of fluoroform (CHF3) in synthetic air at the temperatures 296.90(8) and 296.07(8) and the total pressures 674.69(62) and 748.92(70) Torr, respectively, in the range of 600-1940cm-1. Every spectrum was splitted into 6 regions, containing an isolated absorption feature. This makes 12 *.dat files altogether. Single components are available at https://doi.org/10.7795/720.20250709.Description of the individual files: Each file contains three columns: 1. Wavenumber (in cm-1); 2. Absorption cross section (in cm^2/molecule); 3. Expanded uncertainty (in cm^2/molecule). Method: FTIR Format: .dat (TAB as column separator) Recommended software: MS Excel, Origin (proprietary), or any text editor (e.g., Notepad) Parameters: in the filename in the following format: `CHF3_[temperature in K]_[total pressure in Torr]_air_[wavenumber interval in cm-1]_[nominal resolution in cm-1].dat`This work was done within the project “Metrology for climate relevant volatile organic compounds”, MetClimVOC. The project has received funding from EMPIR programme co-financed by the Participating States and from the European Union’s Horizon 2020 research and motivation programme

    330. PTB-Seminar, Aktuelle Fortschritte von Kalibrierverfahren im Nieder- und Hochfrequenzbereich 2025

    No full text
    Elektrische Messgeräte und Messverfahren haben besonders kurze Innovationszyklen, weil sie mit der allgemeinen Entwicklung elektronischer Geräte Schritt halten müssen. Das stellt die akkreditierten Laboratorien vor die Aufgabe, ihr Angebot an Kalibrierungen ständig den Erfordernissen anzupassen und damit selbst neue Messverfahren zu entwickeln. Unter der Schirmherrschaft des Helmholtz-Fonds e. V. lädt die PTB daher zu einem eintägigen Seminar über "Aktuelle Fortschritte von Kalibrierverfahren im Nieder- und Hochfrequenzbereich" ein, das an ausgewählten Beispielen aus den Bereichen Gleichstrom- und Niederfrequenz sowie Hochfrequenz neue Messmethoden beschreibt und dem Austausch von Informationen und Erfahrungen zwischen den Fachleuten aus der PTB, aus den akkreditierten Laboratorien sowie von weiteren Anwendern aus Industrie und Forschung dienen soll. Ziel des Seminars ist es, Anregungen für neue Messverfahren zu geben, die den Laboratorien helfen, den an sie gestellten Anforderungen gerecht werden zu können.1 Vom Quarz zum rauscharmen und hochstabilen OCXO: wie Phasenrauschen die Welt verändert 2 Fortschritte im Bereich der Phasenrauschmetrologie in der PTB 3 Terahertz Waveguides and Interfaces – Current Progress in Standardization 4 Rückführung von Streuparametern im 0,8mm-Koaxialleitungssystem bis 165 GHz 5 Einfluss von Lokaloszillator-Kabelbewegungen auf VNA-Messungen mit Frequenzerweiterung 6 Aktuelle Entwicklungen in der Nahfeld-Antennenmesstechnik 7 Die Scheu vor der Interpolation beim Einsatz von Digitalmultimetern und Kalibratoren 8 Ortsaufgelöste Charakterisierung magnetischer Feldverteilungen mittels magnetischer Kraftmikroskopie im Vakuum 9 Ringvergleiche von Hochspannungs- und Hochstrommesssystemen innerhalb DAkkS-akkreditierter Kalibrierlabore 10 Messverfahren für die Untersuchung von Energiemessgeräten unter industriellen Betriebsbedingungen 11 Graphen-basiertes Quanten-Hall-Widerstandsnormal im Kleinkühler-Betrieb 12 Einsatz eines Kryostromkomparators in der Widerstandsthermometri

    Liste der von der PTB erteilten Bauartzulassungen nach § 7 Beschussgesetz (BeschG)

    No full text
    Liste der von der PTB erteilten Bauartzulassungen nach § 7 Beschussgesetz (BeschG

    Appendix A

    No full text
    This DCC is part of the DKD expert report DKD-E 7-3 Instructions on how to use the DCC schema to create a digital calibration certificate for non-automatic weighing instruments, Edition 03/2025, Physikalisch-Technische Bundesanstalt, Braunschweig and Berlin. DOI: https://doi.org/10.7795/550.20250325 This is NOT a real calibration certificate

    PriSpecTemp report: literature study on experimental line intensity of CO, CO2 and O2

    No full text
    This report is an overview of the existing literature sources for the atmospheric “sensor" molecules (CO, CO2, O2). Existing accurate measurements of the line intensity in different frequency ranges (molecular bands), suitable for both highly accurate ab initio calculations, measurements, and specification of the reference temperatures are targeted. The document is partitioned as follows: after a brief introduction in the second section, 3rd, 4th and 5th sections are dedicated to carbon monoxide, carbon dioxide and molecular oxygen, respectively

    Liste der bei der PTB zugelassenen Blockiersysteme für Erbwaffen gemäß § 20 Waffengesetz (WaffG)

    No full text
    Liste der bei der PTB zugelassenen Blockiersysteme für Erbwaffen gemäß § 20 Waffengesetz (WaffG

    Entwicklung eines Verfahrens zur Bestimmung von sicherheitstechnischen Kenngrößen von hybriden Dampf-Staub-Luft-Gemischen

    No full text
    Diese Arbeit beschäftigt sich mit der Entwicklung und Validierung einer Methode zur Bestimmung sicherheitsrelevanter Kenngrößen von Hybridgemischen. Grundlage bildet ein neu konzipiertes Messsystem, das auf der 20-Liter-Kugel basiert. Zunächst wurde die Methode anhand reiner Substanzen überprüft, bevor Untersuchungen zur unteren Explosionsgrenze (UEG) durchgeführt wurden. Dabei zeigten sich Einschränkungen hinsichtlich der Zuverlässigkeit der UEG-Bestimmung mit der 20-Liter-Kugel, die weiterführende Analysen erforderlich machten. Anschließend wurden Zündverzögerungszeiten für Hybridgemische mit variierenden Dampf- und Staubanteilen ermittelt. Die Ergebnisse verdeutlichen, dass diese maßgeblich von den spezifischen Gemischzusammensetzungen sowie von fluidmechanischen Effekten beeinflusst werden. Ergänzende Hochgeschwindigkeitsaufnahmen lieferten neue Erkenntnisse zu den strömungsmechanischen Eigenschaften der Gemische und deren Einfluss auf die Wahl geeigneter Zündverzögerungszeiten. Die Arbeit zeigt, dass eine zuverlässige Charakterisierung von Hybridgemischen unter Berücksichtigung fluidmechanischer Parameter notwendig ist und stellt methodische Ansätze für die Anwendung der 20-Liter-Kugel vor. Abschließend wird die Frage diskutiert, inwieweit dieses Verfahren reale Prozesse von Staubexplosionen adäquat abbilden und als Grundlage zur Standardisierung sicherheitsrelevanter Kenngrößen im Explosionsschutz dienen kann.PTB-Bericht Diss-2

    Progress achieved in EURAMET project 21GRD09 MetroPOEM: Metrology for the harmonisation of measurements of environmental pollutants in Europe

    No full text
    The European Green Deal’s ambition for zero pollution requires development of highly sensitive techniques to detect ultra-low amounts of pollutants and isotope ratios, where mass spectrometry is a key method. The MetroPOEM project bridges the traceability gap between activity and mass-based measurements. Low level radioactive standard solutions (90Sr, 237Np, 234U, 236U, natural uranium (Unat), 239Pu, 240Pu, 241Am, 239,240Pu) were distributed to 18 partner laboratories for measurement by mass spectrometric and decay counting techniques. The results and data analysis will be published separately. SI-traceable high precision methods were developed for isotope ratio determination of Li, B, Cr, Cd, Ni, Sb, Pb and U in seawater. Method development addressed analyte separation from the matrix, evaluation of calibration approaches, isotope fractionation corrections and uncertainty estimation. Seawater (250 L) was taken from the German North Sea exclusive economic zone (DE-EEZ) to develop two certified reference materials (CRMs). Part of this material was used to generate a CRM with SI traceability for isotope ratios of Li, B, Cr, Cd, Ni, Sb, Pb and U. The second part was used to generate a seawater CRM, spiked with Unat, 237Np, 239,240Pu and 241Am. A solid silica-based CRM, spiked with Unat, 237Np, 239,240Pu and 241Am, was produced by solgel synthesis, with ~10 kg of inactive material for method development. These materials were characterised in accordance with ISO 17034 by interlaboratory studies between project partners, using techniques developed in the project. Two Good Practice Guides, on (i) measurement of radioactivity by mass spectrometry, and (ii) sample treatment, uncertainties, and mass bias quantification, are in draft

    0

    full texts

    1,101

    metadata records
    Updated in last 30 days.
    Open Access Repository of the Physikalisch-Technische Bundesanstalt (PTB-OAR)
    Access Repository Dashboard
    Do you manage Open Research Online? Become a CORE Member to access insider analytics, issue reports and manage access to outputs from your repository in the CORE Repository Dashboard! 👇