Helmholtz Institute Freiberg for Resource Technology
RODARE Docs (Rossendorf Data Repository - Helmholtz-Zentrum Dresden-Rossendorf, HZDR)Not a member yet
1328 research outputs found
Sort by
Data (11/15) for: Analysen zur Anwendbarkeit verschiedener Strahlbahn-Monitoring-Konzepte für die ultraschnelle Röntgencomputertomografie
Simulationsdaten für die Masterarbeit Analysen zur Anwendbarkeit verschiedener Strahlbahn-Monitoring-Konzepte für die ultraschnelle Röntgencomputertomografie
- Pos_* Simulationsdaten für den ROFEX 3 für verschiedene USRBINs mit EMFCUT=10keV
- Ro1_* Simulationsdaten für den ROFEX 1 mit EMFCUT = 100ke
Data for: Experimental studies on bubble aspect ratio and corresponding correlations under bubble swarm condition
Zip-file that contains the raw images on a study on bubble aspect ratio under swarm condition. Further information can be found in the respective paper
Example Project Plan generated by HELIPORT
This dataset contains the metadata for an example project generated using the project export button in our prototype scientific project lifecycle and workflow management system HELIPORT (HELmholtz ScIentific Project WORkflow PlaTform). The metadata schema is still under development and this entry will be updated to reflect further developments
Data for: Bubble formation from sub-millimeter orifices under variable gas flow conditions
This is the data for the publication ID 32653
Software: Method for real-time controlled tissue theranostics using a single adaptable laser source
Software support for real-time quantification of the treatment effect on the targeted tissue induced by a pulsed laser. Model functions used to quantify laser treatment effect are based on the calculated descriptor values from FLIM (Fluorescence lifetime imaging microscopy) and AF (autofluorescence) diagnostics images done on human retinal tissue using SPC Image software (B&H)
SEM-EDS datasets of titanium alloy wear debris in periprosthetic tissue
SEM-EDS images and datasets of titanium alloy wear debris found in periprosthetic tissue obtained at revision surgery of a fractured titanium-alloy modular neck of a patient with hip osteoarthritis
Numerical and experimental data set obtained from paraffin phantom measurements based on the capacitance wire-mesh sensor.
This data set contains experimental and numerical data from a 12x12 wire-mesh sensor. A 12x12 WMS was used to measure paraffin phantoms created to mimic three flow patterns: slug, annular and bubble flow. The sensor was assembled with flanges and filled with tap water. Two models based on finite element model were used to generate the synthetic data. The first one is a basic FEM model, which was designed based on other models reported in the literature (i.e. the output signal is obtained by integrating the current density over the surface of a receiver wire). In the second model (FEM+EC), the electric potential is solved as the basic one, however, external circuits (macromodels) were coupled to the 3D geometry of the sensor to emulate the excitation and amplification systems of a real WMS.A mapping containing the coordinates and electrical properties of the paraffin phantoms was created through image processing and imported into the software COMSOL v.5.6. Thus, both basic FEM and FEM+EC models were used to generate synthetic data that can be direct compared to the experimental data
Macro to generate muon (g-2) summary plot
This macro gives the status of the muon (g-2) just after the FERMILAB seminar on April 7, 2021.
The theoretical values use the different contributions as given in the
[White Paper](https://arxiv.org/pdf/2006.04822.pdf) of the
[Theory Initiative](https://muon-gm2-theory.illinois.edu/). Since the leading
order hadronic contribution is dominating the uncertainty of the
theoretical values, several values for a are plotted which use the
different evaluations for the leading order hadronic contribution given in
Table 4 of the White Paper as well as the White Paper average
Data publication: A new system for real-time data acquisition and pulse parameterization for digital positron annihilation lifetime spectrometers with high repetition rates
Bei diesem Datensatz handelt es sich um die Bilder zur Publikation und Daten für die Leistungskurve
Data for: Bubble formation from sub-millimeter orifices: experimental analysis and modeling
raw data and processed data for the publication