Devices and Methods of Measurements (E-Journal) / Приборы и методы измерений
Not a member yet
490 research outputs found
Sort by
ИНСПЕКЦИОННЫЕ РОБОТЫ С ПЬЕЗОПРИВОДОМ: МОДЕЛИРОВАНИЕ, СИМУЛЯЦИЯ, ОПЫТНЫЕ ОБРАЗЦЫ
Models, simulations and experimental setups of resonant inspection robots are presented. The goal is to show ways to cope with the new requirements and to use the given chances to create novel mobile robots. For the creation of a directed motion the vibration behavior of simple beams and plates is used. It is possible to design robots for 2-dimesnional locomotion which are characterized by a light weight, small size, relative simple design and the ability to create controllable motion using only one actuator. Different types of actuators for micro robots are presented and compared. Furthermore the dynamical behavior of a piezoelectric bending actuator under elastic boundary conditions is investigated and a model for the motion of the locomotion-generating limbs is presented. The comparison with experiments and prototypes shows that the results of the analytical and computational models agree Приведены конструкции, представляющие собой симуляции и экспериментальные модели инспекционных микророботов, работающих на основе резонансных колебаний. Использование разработанных подвижных систем позволит создать микророботы, соответствующие новым требованиям разработчиков. Для создания направленного движения инспекционных микророботов используются вибрационные колебания балки на опорах и пластин. Показана возможность создания резонансных инспекционных роботов для двумерного движения и контроля, которые будут иметь небольшой вес, маленькие размеры и относительно несложный дизайн. Измерение параметров резонанса позволяет получить информацию о характерных особенностях опорной исследуемой поверхности Управляемое движение и контроль осуществляется за счет активации только одного элемента микроробота. Сравниваются различные типы механизмов для микророботов; представлены результаты исследования динамических свойства пьезоэлектрического механизма изгиба пластин в границах упругой зоны. Представлена модель движения, порождаемого ножками робота.
ПРИМЕНЕНИЕ РАДИОМЕТРИЧЕСКОЙ СИСТЕМЫ КРАЙНЕ ВЫСОКИХ ЧАСТОТ ДЛЯ ОБНАРУЖЕНИЯ ЗЛОКАЧЕСТВЕННЫХ НОВООБРАЗОВАНИЙ МОЛОЧНЫХ ЖЕЛЕЗ
Developed and investigated radiometric system EHF (extremely high frequency) range for the diagnosis of tissue samples affected by carcinoma. EHF system are significantly higher than in the possibility of identifying a lower frequency range, as in UHF band (UHF band) and UHF (ultra high frequency) resolution of 1-3 mm are impossible. It was established that the affected carcinoma tissue samples are 3 dB lower transmittance compared to unaffected tissues. Analysis of the dependency of the harmonic components of the modulation signal passing through the examined tissue samples shows dramatic difference in the behavior of the harmonic components of the frequency domain. This phenomenon appears to altered tissue the presence of slumps that due to the interaction of electromagnetic waves with the tissue samples may be explained by the so-called stochastic resonance effect. Разработана и исследована радиометрическая система диапазона крайне высоких частот для диагностики образцов тканей, пораженных карциномой. Ее возможности существенно превосходят возможности идентификации в диапазонах более низких частот, так как в диапазонах дециметровых волн и сверхвысоких частот разрешение 1–3 мм невозможны. Установлено, что пораженные карциномой образцы тканей имеют на 3 дБ меньший коэффициент прохождения по сравнению с непораженными тканями. Анализ приведенных зависимостей гармонических составляющих модуляционного сигнала, прошедшего через образцы исследуемых тканей, показывает резкое отличие поведения гармонических составляющих в частотной области. Данное явление наблюдается для измененной ткани – наличие резких спадов, что обусловлено взаимодействием электромагнитных колебаний с образцами тканей и может быть объяснено так называемым эффектом стохастического резонанса
УПРОЩЕННЫЕ МЕТОДЫ ИЗМЕРЕНИЯ НАПРЯЖЕННОДЕФОРМИРОВАННОГО СОСТОЯНИЯ КУЗОВА-КОНТЕЙНЕРА ПЕРЕМЕННОГО ОБЪЕМА
The developed original methodology is designed for testing van containers for cross-section and longitudinal sidesway typical in normal operation and does not require implementation of high cost equipment, devices, massive base or plates. The offered loading pattern and test methodology is highly cost effective, e.g. with minimum expenses it is possible to estimate the structural behavior of van containers, which is crucial for their development, manufacture and operation and makes it possible to hold trials at the enterprise, aimed at improvement of non-cargo container design.Разработана оригинальная методика испытаний кузовов-контейнеров на поперечный и продольный перекосы, характерные для эксплуатации, не требующая дорогостоящих оборудования, приборов, массивного фундамента и плит. Предложенная схема нагружения и методика испытаний позволяют с минимальными затратами оценить прочностные свойства кузовов-контейнеров, что является существенным при их разработке, производстве и эксплуатации, и открывают возможности для проведения исследований на предприятиях по совершенствованию конструкций контейнеров негрузового тип
ЭКСПРЕСС-МЕТОДИКА БЕСКОНТАКТНОГО ИЗМЕРЕНИЯ ЭЛЕКТРИЧЕСКИХ ПАРАМЕТРОВ НЕБОЛЬШИХ ОБРАЗЦОВ НА СВЕРХВЫСОКИХ ЧАСТОТАХ
The setup with a reflective microwave H101 resonator for the non-contact measurements of the electrical parameters of compact samples (the diameter less than 5 mm) is constructed. An analytical expression for calculation of the microwave power reflection coefficient by the H101 resonator with the sample being inside the resonator with respect to the dielectric permittivity and conductivity of sample is obtained. The dependence of the microwave power reflection on the diameter of the metallic and glassy globs freely falling through the resonator is experimentally found. an>Разработана установка с отражательным СВЧ-резонатором типа H101 для бесконтактного измерения электрических параметров небольших (диаметром ≤ 5 мм) образцов. Получено аналитическое выражение для расчета коэффициента отражения мощности СВЧ-излучения H101-резонатором с находящимся в нем образцом в зависимости от диэлектрической проницаемости и электропроводности образца. Экспериментально найдена зависимость отражения СВЧ-мощности от диаметра металлических и стеклянных шариков при их свободном падении через резонато
МЕТРОЛОГИЧЕСКОЕ ОБЕСПЕЧЕНИЕ ИЗМЕРЕНИЯ КОЭФФИЦИЕНТА ТЕПЛОПРОВОДНОСТИ
A two-stage method of intralaboratory research of characteristics of accuracy of the method of measurement of thermal conductivity was developed and implemented. The criterion determining the necessity of performing the second stage of research was formulated. The technique allows to identify sources influenced on the result of measurement of thermal conductivity, and also to control characteristics of the method (precision). Recommendations for research of the National reference unit of thermal conductivity were developed.Разработана и реализована двухэтапная методика внутрилабораторного исследования характеристик точности метода измерения коэффициента теплопроводности. Сформулирован критерий, определяющий необходимость подключения второго этапа исследований для достижения поставленной цели. Методика позволяет объективно выявлять источники, влияющие на результат измерения коэффициента теплопроводности, а также управлять характеристиками метода (прецизионности). На основании проведенного исследования разработаны рекомендации по исследованию Национального эталона единицы теплопроводности.
АДАПТАЦИЯ РАЗРАБОТАННОЙ МЕТОДИКИ ОЦЕНКИ СОСТОЯНИЯ МЕТАЛЛОКОНСТРУКЦИЙ К КОНТРОЛЮ ИЗДЕЛИЙ С НАПЛАВЛЕННЫМИ ПОКРЫТИЯМИ
The technique of metalware condition estimation is worked out by authors. Questions of its adaptation to the quality assurance of restored and strengthened details and tools with the wearresistant coatings deposited are discussed. Magnetic and durometrie methods of nondestructive control used in order to estimate the exploitation reliability of details with welded coatings. Efficiency of this methods is confirmed.Рассмотрены вопросы адаптации разработанной авторами методики оценки состояния металлоконструкций к контролю качества восстановленных и упрочненных деталей и инструментов с нанесенными на них износостойкими покрытиями. Подтверждена эффективность применения магнитного (по коэрцитивной силе) и дюрометрического методов неразрушающего контроля для оценки надежности эксплуатации изделий с наплавленными покрытиями
РЕГИСТРИРУЮЩИЕ СИСТЕМЫ ДЛЯ РАДИАЦИОННОГО НЕРАЗРУШАЮЩЕГО КОНТРОЛЯ НА ОСНОВЕ ТРЕХКОМПОНЕНТНЫХ РАСТВОРОВ ОРГАНИЧЕСКИХ КРАСИТЕЛЕЙ
Spectral properties of a number of three-component organic dyes of various classes solutions subjected to radiation by gamma and x-ray radiation are investigated. Based on the criteria for the selection of multi-component dye solutions for radiation defectoscopy (presence of dyes intense absorption bands in the visible region of the spectrum, good solubility in the selected solvent, no chemical interaction with each other and with the product of dyes radiation degradation, a significant difference in the rates of radiation degradation of dyes, low feding), it shows that the most promising solutions of the following pairs of dyes (one of which absorbs short-wave, the other – in the longer wavelengths of the visible spectrum): acid yellow fast light + acid green anthraquinone N2B, acid yellow fast light + acid bright blue G, trypaflavine + methylene blue, acid scarlet + methylene blue, uraninite + methylene blue, rhodamine 6G + acid bright blue G, eosin sodium + acid bright blue G, eosin sodium + acid green anthraquinone N2B, lanazol orange + acid bright blue G , lanazol orange + acid green anthraquinone N2B.
МОДЕЛИРОВАНИЕ И ОПТИМИЗАЦИЯ ПОРТАТИВНОГО ПРИБОРА НАБЛЮДЕНИЯ ПОСРЕДСТВОМ АНАЛИЗА ЖЕСТКОСТИ ЕГО КОНСТРУКЦИИ В СРЕДЕ САПР PRO/ENGINEER
The 3D model of the portable device of supervision using SAPR Pro/ENGINEER is constructed. By means of the module of the engineering analysis built in this package the mechanical analysis of rigidity of a product design is carried out. Own frequency fluctuations of a product by orthogonal axes and the corresponding points of the maximal tension concentration in optical and mechanical components under the influence of their gravity are determined.В САПР Pro/ENGINEER построена 3D-модель портативного прибора наблюдения. Посредством встроенного в данный пакет модуля инженерного анализа проведен механический анализ жесткости конструкции изделия. Определены собственные частотные колебания прибора по ортогональным осям и соответствующие точки максимальной концентрации напряжений в оптических и механических компонентах под действием их силы тяжести
МЕТОДИКА ПРОВЕДЕНИЯ ЭКСПЕРИМЕНТАЛЬНЫХ ИССЛЕДОВАНИЙ ПО ОПРЕДЕЛЕНИЮ МАССОВОЙ ДОЛИ ЭЛЕМЕНТОВ В СТАЛЯХ ПРИ ФОТОЭЛЕКТРИЧЕСКОМ СПЕКТРАЛЬНОМ МЕТОДЕ
Мethod for the measurement and selection of reference materials for photoelectric method of spectral analysis of steels (according ГОСТ 18 895) shows for research on atomic emission spectrometer DFS-71. Приведена методика проведений измерений и выбора стандартных образцов при фотоэлектрическом методе спектрального анализа состава сталей (в соответствии с ГОСТом 18895) при проведении исследований на атомно-эмиссионном спектрометре ДФС-71.
ВЛИЯНИЕ ХАРАКТЕРИСТИК ИЗЛУЧЕНИЯ ЛАЗЕРОВ НА ТОЧНОСТЬ КАЛИБРОВКИ СРЕДСТВ ИЗМЕРЕНИЙ
Investigated the influence of power stability and spectral characteristics of the radiation of the lasers included in the complex of setups for calibration of laser power and energy meters which provides reproducibility of the unit of average laser power in the range from 10-7 to 40 W and laser energy in the range from 10-7 to 100 J with a relative standard uncertainty not more than 3 % at the wavelengths range from 0,2 up to 10,6 μm for the results of calibration of measuring instruments. Исследовано влияние стабильности мощности и спектральных характеристик излучения лазеров, входящих в состав комплекса установок для калибровки средств измерений мощности и энергии лазерного излучения, который обеспечивает воспроизведение единицы средней мощности лазерного излучения в динамическом диапазоне от 10-7 до 40 Вт и единицы энергии лазерного излучения – от 10-7 до 100 Дж с относительной стандартной неопределенностью, не превышающей 3 % в спектральном диапазоне от 0,2 до 10,6 мкм, на результаты калибровки средств измерений.