2383 research outputs found
Sort by
Publicações ampliadas: um novo modelo de publicação acadêmica para o ambiente de e-science
Assessment of environmental impact caused by the release of radionuclides in Ilha Grande Bay after an accident at the nuclear power plant
7 p. il.This study aimed to evaluate the impact of a postulated accidental release of radionuclides from a nuclear power reactor into the aquatic resources, using an environmental modeling. To achieve that, computational models of hydrodynamics and transport were used to simulate the radionuclides dispersion caused by an accident in a PWR. This exercise was accomplished with the aid of a code system (SisBAHIA) developed at Rio de Janeiro Federal University (COPPE/UFRJ). The nuclear power plant Angra 3 is a reactor that uses pressurized light water as moderator and coolant in the core. Where 431 m³ of soda almost instantaneously was lost. This inventory contained 1.87x1010 Bq/m³ of tritium, 2.22x107 Bq/m³ of cobalt, 3.48x108Bq/m³ of cesium and 3.44x1010 Bq/m³ of iodine and was released in liquid form near the Itaorna cove, Angra dos Reis – RJ. Applying the model in the proposed scenario [1-2], the simulated dilution of the specific activity of radionuclide spots, reached values much lower than report levels for seawater (1,1x106 Bq/m³, 1,11x104 Bq/m³, 7,40x10² Bq/m³ and 1,85x103 Bq/m³) after 22 hours, respectively for ³H, 60Co, 131I and 137 Cs
Safety culture assessment: a fuzzy model for improving safety performance in a radioactive installations
Produção de I-124 com uso de nanomateriais e sua biodistribuição em animais
O iodo-124 é um emissor de pósitron com 4,2 dias de meia vida física. Seu decaimento dá-se por emissão de pósitrons (23,3%) e captura eletrônica (76,7%). Suas características físicas e químicas o tornam um isótopo atrativo para aplicações médicas. O desenvolvimento de novas técnicas de imagens, melhorias na tecnologia do Tomografia por Emissão de Pósitrons (PET), o desenvolvimento de novos detectores e métodos computacionais de processamento de sinal, abrem novas perspectivas para a sua aplicação. Os crescentes usos da tecnologia PET em oncologia, em estudos de farmacocinética e de metabolismo de drogas, fazem dos radiofármacos marcados com 124I uma ferramenta de grande interesse e utilidade. O uso de moléculas marcadas com 124I destaca-se especialmente devido à conveniente meia-vida do 124I. Esta característica possibilita diagnóstico por imagens, em centros PET longe do local de produção de radionuclídeos. Dentro deste contexto, este trabalho apresenta um método de produção e separação de 124I. Este método é inovador e pioneiro no país. Baseia-se no desenvolvimento e utilização de alvos de natTeO2 nanoestruturados. Estes alvos são irradiados em um acelerador de partículas carregadas, de energia variável, o cíclotron CV-28 do IEN. As irradiações são realizadas com feixes de prótons de 24 MeV de energia inicial. Na preparação dos alvos nanos particulados o destaque foi a simplicidade do método, que usa a técnica de sol-gel para obtenção de nano partículas, o TeCl4 como precursor e a água como solvente. O 124I produzido foi separado do material alvo por destilação seca e capturado numa solução de NaOH (0,02M), em sistema automatizado. O rendimento de alvo grosso foi de 6,81 MBq/Ah, sendo o rendimento da síntese de aproximadamente 90%. O 124I obtido foi então utilizado em estudos preliminares de biodistribuição. Estes estudos forma realizados em um MicroPET, modelo LabPET4 do CDTN, em camundongos tipo Swiss. Os resultados da aplicação de Na124I mostraram alta qualidade de imagem PET da tireoide, sendo que a máxima captação deu-se 6h após injeçãoIodine-124 is a positron emitter with physical half-life of 4.2 days. Its decay occurs by positron emission (23.3%) and electron capture (76.7%). Their physical and chemical characteristics make it an attractive isotope for medical applications. The development of new imaging techniques, improvements in Positron Emission Tomography (PET), the development of new detectors and computational methods of signal processing, open new perspectives for its application. The increasing use of PET technology in medical oncology, pharmacokinetics and drug metabolism, make the radiopharmaceuticals labeled with 124I a tool of great interest and usefulness. The use of 124I - labeled molecules stands out particularly due to the convenient half-life of 124I. This feature enables diagnostic imaging in PET centers far away from the radionuclides producing center. Within this context, this work presents a method for the production and separation of 124I. This method is innovative and pioneering in the country. It is based on the development and use of nanostructured targets of natTeO2. These targets are irradiated in a charged particles accelerator, with variable energy, the IEN´s CV-28 cyclotron. The irradiations are performed with 24 MeV, initial energy, proton beams. In the preparation of nanoparticulated targets the highlight was the simplicity of the method that uses the sol-gel technique for obtaining nanoparticles, TeCl4 as precusor and water as solvent. The produced 124I was separated from the target material by dry distillation and trapped in a NaOH solution (0.02M), in an automated system. The thick target yield was 6.81 MBq/Ah, and the synthesis yield was 90%. The 124I obtained was then used in preliminary biodistribution studies. These studies were performed on a microPET, model LabPET 4 of the CDTN, in Swiss type mice. The results of the application of Na124I showed high quality PET imaging of the thyroid, with the maximun uptake at 6h after injectio
Estudo do acidente com perda de refrigerante de um reator PWR através de um simulador de escopo compelto e do código computacional RELAP
The present paper porposes a study of a loss of coolant accident of a PWR reactor through a Full Scope Simulator and computational code RELAP. To this end, it considered a loss of coolant accident with 160 cm2 breaking area in cold leg of 20 circuit of the reactor cooling system of nuclear power plant Angra 2, with the reactor operating in stationary condition, to 100% power. It considered that occurred at the same time the loss of External Power Supply and the availability of emergency cooling system was not full. The results obtained are quite relevant and with the possibility of being used in the planning of future activities, given that the construction of Angra 3 is underway and resembles the Angra 2.O presente trabalho propões um estudo de um acidente com perda de refrigerante de um reator PWR através de um Simulador de Escopo Completo e do código computacional RELAP. Para tal, foi considerado um acidente com perda de refrigerante com área de quebra de 160 cm2 na perna fria do circuito 20 do sistema de refrigeração do reator da planta da Usina Nuclear de Angra 2, com o reator operando em condições estacionária, a 100% de potência. Foi admitido ainda, que ocorreu simultaneamente a perda de Suprimento Externo de Energia Elétrica e que a disponibilidade do Sistema de Refrigeração de Emergência do Núcleo não era plena. Os resultados obtidos apresentam-se bastante relevantes e com possibilidade de serem usados no planejamento de atividades futuras, visto que a construção de Angra 3 se apresenta em andamento e se assemelha a Angra 2
Incrustation detection system for petroleun transport pipes based on gamma transmition
The scale formed over the inner walls of the ducts conveying the extracted
product from offshore oil wells is a major cause of losses to companies and in some
cases even the safety is affected. The consequence of such fouling is the duct´s
square section reduction that causes extraction flow decrease and can also cause an
increase in pressure inside the well, with serious consequences for safety.
The objective of this work is to propose a mobile inspection system, which can
be transported by underwater robots to inspect the lines of ducts in the outputs of the
oil wells. The measurement method to be adopted will be the gamma rays´ beam
attenuation at a predetermined position of the pipe. This transmission value compared
to a clear pipe reading will show if the thickness of the inlay is larger or smaller than an
assumed thickness.
To carry out the measurements it was designed and built an electronic system
comprising power supply, amplifier, single channel analyzer and a counter timer that
was connected to a CsI scintillator detector coupled to a PIN photodiode. The system
was set up to perform measurements with constant accuracy of ±1%.
Tests during the study demonstrated the effectiveness of the proposed method
with the obtained results with a carbon steel duct section of 270 mm diameter, removed
from the field, with asymmetric BaSO4 inlay.As incrustações que se formam nas paredes internas dos dutos de transporte
do produto extraído dos poços marítimos de petróleo é motivo de grande prejuízo para
as companhias exploradoras e em alguns casos até mesmo de segurança. A
consequência dessas incrustações é a diminuição da seção reta do duto que causa a
diminuição da vazão de extração e pode também causar um aumento da pressão no
interior do poço, com graves consequências para a segurança.
O objetivo deste trabalho é propor um sistema de inspeção móvel, que pode
ser transportado por robôs submarinos para inspecionar as linhas de dutos nas saídas
dos poços de petróleo. O método de medida a ser adotado será o da atenuação da
transmissão de um feixe de raios gama que fará uma única leitura em uma posição
pré-determinada e nos dará como resultado a informação se a espessura da
incrustação é maior ou menor do que um valor pré-determinado.
Para a realização das medidas foi projetado e construído um sistema eletrônico
composto de fonte de alimentação, amplificador, analisador monocanal e contador que
foi acoplado a um detector cintilador de CsI com fotodiodo PIN. O sistema de medida
foi ajustado para realizar medidas com precisão constante de ±1%.
Nos testes realizados durante a pesquisa ficou demonstrado a eficácia do
método proposto com os resultados obtidos com uma seção de tudo de aço carbono
de 270 mm de diâmetro, retirado do campo, com incrustações assimétricas de BaSO4
Desenvolvimento de Tecnologia para Sistemas Complexos
ÁREA DE PESQUISA: Fatores humanos/Inteligência artificial/Confiabilidade humana/Engenharia de Resiliênci