Qucosa – Hemholtz-Zentrum Dresden-Rossendorf
Not a member yet
801 research outputs found
Sort by
Surface Light Scattering Spectroscopy of the Gallium Liquid-Vapor Interface
Surface Light Scattering Spectroscopy of the Gallium Liquid-Vapor Interface Vladimir Kolevzon Abstract High frequency capillary waves at liquid Ga surface have been studied by means of quasielastic light scattering spectroscopy. The observed frequencies and damping constants of waves differed greatly from classical theoretical treatment of liquid Ga surface as that of a simple liquid. This effect was explained due to the presence of the surface layer, possessing visco-elastic properties extracted, for the first time, from the fit of experimental spectra with an appropriate theoretical form. Negative value of the surface dilational viscosity has been derived for all wavenumbers studied. At high wavenumbers q the wave dispersion behavior is best likely linked to the weak coupling between dilational and capillary modes, while at low and moderate q the experimental data resemble to the mixed oscillations. This behavior is consistent with an influence of diffusion and adsorption on the waves propagation
Charakterisierung der Submicron-Partikel in einem umweltrelevanten Wasser: Stauwasser in einer Kommunalmülldeponie über einem Schlammteich (Tailing) der Uranerzaufbereitung in Freital/Sachsen
Characterization of Submicron Particles in an Environmentally-Relevant Water: Backwater From a Sanitary Landfill on a Uranium Mine Tailing at Freital, Saxony. A strategy for characterizing submicron particles in environmental waters based on filtration, centrifugation and photon correlation spectroscopy (PCS) is proposed. Filtration and centrifugation are not used here as methods for particle characterization but serve merely as techniques of a rough separation of the sample. They are applied as cautiously and non-invasively as possible and are only aimed at separating the sample sufficiently for measurements by primarily PCS. The separation should unmask small particles that scatter little light and divide the sample into populations of particles that have monomodal or bimodal size distributions. In this way, the strategy optimizes subsequent particle-size determinations by PCS and minimizes the influence of sample preparation on the samples. A further essential feature of this strategy is the parallel application of complementary methods for both sample preparation and particle characterization (filtration/centrifugation, PCS/SEM, gravimetry/ICP-MS etc.). This facilitates the validation of results and increases the probability for recognizing artifacts. Based on our experimental experience, a guideline for PCS measurements on low-concentration colloids with the BI 90/Correlator BI 9000 AT system from Brookhaven Instruments Corp. was developed. This guideline is aimed at obtaining autocorrelation functions of sufficiently good photon counting statistics which is crucial in PCS on colloidal solutions poor in particles. A measuring campaign on an environmentally-relevant water (backwater from a sanitary landfill on a uranium mine tailing at Freital, Saxony) showed the presence of about 1 to 2 mg/l of submicron particles having a particle size of 30 to 300 nm and of about 5 mg/l of suspended matter (>1000 nm)
Electromagnetic signals from deconfined matter resulting from ultrarelativistic heavy-ion collisions
Lieferung von Investitionsgütern zur Erhöhung der Betriebssicherheit des Kernkraftwerkes Saporoshje - Betriebliche Überwachung, 2. Realisierungsstufe -
Im Rahmen eines Programms des Bundesministeriums für Umwelt, Naturschutz und Reaktorsicherheit zur Zusammenarbeit mit den MOE-Staaten und der GUS auf dem Gebiet der kerntechnischen Sicherheit hat das Forschungszentrum Rossendorf, Institut für Sicherheitsforschung, im Verbund mit dem technischen Überwachungsverein TÜV Rheinland, Institut für Kerntechnik und Strahlenschutz, die einvernehmlich spezifizierten "technischen Mittel für ein System zur verbesserten betrieblichen Überwachung" an das Kernkraftwerk Saporoshje, Ukraine, geliefert und in Betrieb genommen. Im vorliegenden Bericht (Textteil) werden die Lieferungen und Leistungen nach Art und Umfang (Beschaffenheit, Abnahmeprüfung, Übergabe und Inbetriebnahme der technischen Mittel und die für das ukrainische Fachpersonal durchgeführten Schulungsmaßnahmen) bis zur Aufnahme des Probebetriebes am 30. November 1995 beschrieben. Dem Bericht ist ein Anhang A mit Vorschlägen zur Gestaltung der automatisch arbeitenden Überwachungssoftware und ein Anhang B mit wissenschaftsorganisatorischen Details beigefügt
Elektroenergieerzeugung einer kombinierten Wind-Photovoltaik-Anlage in Ottendorf-Okrilla (Sachsen)
Vom Zentrallager der Plus-Warenhandelsgesellschaft in Ottendorf-Okrilla (Sachsen) wird seit 1992 eine hybride Wind-Photovoltaik-Anlage zur Erzeugung von Elektroenergie betrieben. Die Anlage besteht aus einer 60-kW-Windkraftanlage des Typs TW 60 und einer Phtovoltaikanlage mit einer Spitzenleistung von 3,18 kW. Letztere zeichnet sich durch einige Besonderheiten (Orientierung des Generators, Master-Slave-Betieb der Wechselrichter) aus. Das Betriebsverhalten der Anlagen wurde über einen längeren Zeitraum untersucht. Im Jahr 1995 erreichte die Photovoltaikanlage mit 689 Vollastbetriebsstunden etwa die Ergebnisse anderer Photovoltaikanlagen in Sachsen. Mögliche höhere Erträge werden durch die gewählte Orientierung des Generators verhindert. Die Master-Slave-Schaltung der Wechselrichter arbeitete ohne Probleme. Ihre Effektivität wurde durch die nicht optimale Abstimmung von Generator- und Wechselrichterleistung beeinträchtigt