    Introdução e avaliação de cultivares e porta-enxertos de citros em Rio Branco-AC.

    No full text
    O presente estudo tem como objetivo avaliar o desempenho de 17 cultivares e 4 porta-enxertos de citros, nas condições edafoclimáticas de Rio Branco-AC

    Influence of ac ageing on space charge dynamics in LDPE

    No full text
    Polymeric materials have been widely used as insulation in power industry due to their excellent electrical properties. However, these properties deteriorate in time irreversibly when the material is subjected to electric stress. Although space charge is believed to play an important role in ac ageing, exact mechanisms are poorly understood due to very limited experimental data. In the present work efforts have been made to investigate the influence of ac ageing on space charge dynamics in low-density polyethylene (LDPE). LDPE films with 200mm were aged at 50 kV/mm at 50 Hz for various times at ambient temperature. Space charge dynamics in the samples prior to and after ageing were monitored using the pulsed electroacoustic (PEA) technique under dc electric stress. The results indicate that there is a significant amount of homocharge accumulation in the unaged sample due to charge injection. These injected charges are the captured by the deep traps originated from the interface between crystalline and amorphous regions in LDPE. Ageing under ac condition does not necessarily lead to an increase in amount of charge in the bulk but leads to an increase in mobility of charge carriers. Chemical analysis by infrared spectroscope (FTIR) reveals there are chemical changes taken place in the bulk of the material after ac ageing. It is believed that the chemical changes introduce shallow traps which promote the movement of charge carriers in the bulk. Consequently, the injected charges spread across the sample

    A power sharing series power BJT array with isolated low voltage control for AC power control applications

    No full text
    A technique for a continuously variable AC resistance using a series BJT array is presented. This array provides high power dissipation capability and uniform voltage and power distribution across the individual transistors. The array, controlled using a set of optoisolators to maintain the electrical isolation between the control circuits and the power stage, could be used as the basis to develop several useful techniques including a solid state AC regulator with comparable performance to the commonly used ferro-resonant systems; a linear AC electronic load suitable for testing UPS and other power conditioners; and, in other AC power control applications such as switching capacitors in AC resonant circuits

    The influence of frequency of AC component on space charge behaviours in polyethylene under combined AC and DC electric fields

    No full text
    Combined ac and dc voltages may occur in high voltage power transmission system, which bring challenges to the dielectric materials. Generally speaking, space charge is well recognised under high voltage dc conditions but has received little attention under high voltage ac conditions. Under ac electric fields, the formation space charge in the material depends strongly on the frequency. The knowledge of space charge behaviour in dielectric materials under combined voltages is desirable in terms of both experimental and simulation. In this paper, a numerical model based on the bipolar charge injection/transport model is used to analyse characteristics of space charge in polyethylene under combined electric fields at room temperature. The DC component ratio and the overall root mean square (RMS) are kept the same, while the frequency of the AC component is altered from O.05Hz to 50Hz. It has been found that the amount of the accumulated charges reduces with increasing frequency due to the more frequent polarity reversal. Moreover, the time to reach the steady states of charge amount increases with frequency as wel

    Space charge and charge trapping characteristics of cross-linked polyethylene subjected to ac electric stresses

    No full text
    This paper reports on the result of space charge evolution in cross-linked polyethylene (XLPE) planar samples of approximately 220 ?m thick. The space charge measurement technique used in this study is the PEA method. There are two phases to this experiment. In the first phase, the samples were subjected to dc 30 kVdc/mm and ac (sinusoidal) electric stress level of 30 kVpk/mm at frequencies of 1 Hz, 10 Hz and 50 Hz ac. In addition, ac space charge under 30 kVrms/mm and 60 kVpk/mm electric stress at 50 Hz was also investigated. The volts off results showed that the amount of charge trapped in XLPE sample under dc electric stress is significantly bigger than samples under ac stress even when the applied ac stresses are substantially higher. The second phase of the experiment involves studying the dc space charge evolution in samples that were tested under ac stress during the first phase of the experiment. Ac ageing causes positive charge to become more dominant over negative charge. It was also discovered that ac ageing creates deeper traps, particularly for negative charge. This paper also gave a brief overview of the data processing methods used to analyse space charge under ac electric stress

    Experimental High-Frequency Parameter Identification of AC Electrical Motors

    No full text
    In order to predict conducted electromagnetic interference in inverter-motor drive systems, high-frequency (HF) motor models are requested and the involved parameters have to be available. In previous studies, the authors have presented an accurate HF model for induction motors and they have defined the procedures to identify the model parameters. In this paper, these results are extended to several types and sizes of industrial ac motors such as induction, synchronous reluctance (without interior permanent magnets), and brushless motors. The model parameter-identification procedure has been improved, and it is based on a least-squares data fitting applied to the measured magnitude and phase-frequency-response curves of the phase-to-ground and the phase-to-neutral impedances. The aim of this paper is to provide quick indications to select the suitable values of the HF model parameters, with reference to the size and type of the ac motor, to evaluate the HF voltage and current components in inverted-fed ac motor system

    ac duct cleaning in dubai

    No full text
    Are you looking for the best AC duct cleaning services? Well, you have hit the right place to get excellent services. Ideal Cleaning offers vent and AC duct cleaning services in Dubai to meet your requirements. Our certified AC duct cleaners are highly experienced and trained to complete their job excellently. Hire ac duct cleaning in dubai our professional AC duct cleaners to maintain your home or commercial air ducts

    Using the AC Drive Motor as a Transducer for Detecting Electrical and Electromechanical Faults

    No full text
    Condition monitoring of AC motors is a subject area that has received extensive research. Whether this monitoring is carried out on a scheduled basis by engineer intervention, or continuously using an on-line unit, the results of this testing enable preventative maintenance work to be a carried out earlier, before any major failure occurs. Monitoring using vibration analysis is the most common and depending on the plant, can be done once or twice a year. This is usually limited to the condition of motor bearings and is not commonly used to detect failures in the motor electromagnetic systems. Monitoring units that use motor current measurements are also available, but these are less widely-used and usually on major plant motors (>250kW for example) that have a large capital outlay to replace. The industry drivers – as always – are maximum plant and machinery uptime, with the minimal amount of scheduled maintenance. If maintenance is carried out too regularly, costs rise significantly not only due to the maintenance activity itself, but disruption to production schedules. Maintenance schedules that are too infrequent can result in an unacceptable rise in total failures of plant that are unexpected and may cause a significant amount of production disruption and downtime, especially if this occurs during out-of-hours working time. However, industry now faces another big challenge and one that has had a good share of exposure over the last few years. It is of course, the drive to reduce carbon emissions and with it the amount of energy that a plant itself consumes. What has brought this more to the fore recently is the significant rise in energy costs. Whilst product margins have to remain the same, many companies energy costs have seen a two to three-fold increase in energy budgets in the last few years alone. For industry processes that have a significant amount of fan and pump applications, the manufacturers of low-cost AC inverters have saturated the lower-performance market of inverter drives such that any drive can control these type of fan and pump applications, where accurate speed control is not a major driver. Unfortunately, this can be a step backwards for end-users of plant that use equipment to monitor motor condition via motor current signals. Additionally, vibration analysis that relies upon ‘base-lining’ motor data when the AC motor is running at base speed may not give accurate readings when the motor is under inverter control and running at a different speed. For manufacturers of AC inverter drives in this low-end market, it can be difficult to sell a product from one manufacturer over another without the unit having a “USP”, or Unique Selling Proposition. Most decisions taken on inverter equipment purchase at this level are usually in favour of the equipment that costs the least to purchase. Credibility of manufacturers based on product history and perceived reliability cuts little ground with an ever cost-conscious industry. This is where the research into diagnosis of faults on inverter driven motor systems can provide just this USP for manufacturers. If the incorporation of on-line diagnosis for simple inverter applications can be brought to a typical inverter unit at a reasonable cost, the manufacturer who can offer this gains a unique foothold in the marketplace – a drive that can monitor and signal that the motor it is driving is showing signs of early failure. It will be sensible to limit this research to simple inverter applications as high-end inverter drives that operate equipment such as high-speed printing presses, rotary shears will be more difficult to model and simulate than a fan or pump application. It is hoped that a typical inverter drive can relay enough detailed information about the load which it is driving to allow this to be used for abnormal motor load conditions as this will provide a platform on which to extend the research beyond this MSc and into the realms of incorporating such technology into a drive manufacturers equipment. If this can be done without major modification to an inverter, then it may be easier to implement in equipment offered by different manufacturers. It is quite possible that this technology could be licensed under a name that guarantees the performance of the condition monitoring algorithms and reliability from one drive manufacturer to another

    Experimental studies of influence of DC and AC electric fields on bridging in contaminated transformer oil

    No full text
    Analysis of real operating condition revealed that HVDC transformers experience combined effect of DC biased AC electric field. The dynamics of pressboard particle in contaminated transformer oil under the influence of DC, AC and DC biased AC electric field has been investigated in this paper. Different levels of particle concentrations are tested at different applied voltages. Optical images of the particles accumulation together with conduction current have been recorded during the experiments. A complete bridge between the electrodes of cellulose particles were observed for all the tests carried out under DC and DC biased AC electric field. Opposite to that, for AC experiments, pressboard particles accumulated on surfaces of both electrodes but did not create a full bridge between the electrodes. It is concluded that a combination of DC and AC voltages in a HVDC transformer could lead to a bridge formation within the equipment which could cause failure

    Greenhouse AC-yhtyeen konsertti

    No full text
    Greenhouse AC-yhtyeen konsertti Helsingissä, Bar Loosessa, Stupido Records levy-yhtiön 30 v. juhlissa
    corecore