    Application of CT in Diagnosing Carcinoma of the Maxillary Sinuses : PART 2: An Experimental Study of Pitfalls Encountered when Diagnosing Carcinoma of the Maxillary Sinuses with CT

    Full text link
    1982-03A phantom simulating the transverse section of the maxillary sinuses was constructed for experimentation with various CT scanners to study the following: (1) the occasional inability to image the very thin posterior-lateral walls which have no real bone defects, and (2) to verify whether or not the bony walls surrounding the maxillary sinuses are actually as thick as they appear on CT. The phantom was made of an acrylic cylinder containing three cavities simulating the maxillary sinuses and the nasal cavity and filled with water. The walls, made of thin aluminum and acrylic plates and placed between water and air, disappeared in some CT images. The thickness of the walls calculated from CT values was greater than the true thickness imaged by each CT scanner. The author stresses that in CT images, either experimentally or clinically, thin bony walls placed between water and air or fat tend to disappear, and that bony walls tend to appear thicker than their true thickenss.departmental bulletin pape

    Time-lapse helical X-ray computed tomography (CT) data of tensile fatigue damage in GFRP

    No full text
    The X-ray CT data here is published with the paper -   Wang, Y.; Mikkelsen, L.P.; Pyka, G.; Withers, P.J. Time-Lapse Helical X-ray Computed Tomography (CT) Study of Tensile Fatigue Damage Formation in Composites for Wind Turbine Blades. Materials 2018, 11, 2340. https://doi.org/10.3390/ma11112340 More information about the data and the material can be found in the paper above.   If using the data here, please cite the above paper.  Contact details for author: Ying Wang, [email protected]</p

    Development of a synthetic phantom for the selection of optimal scanning parameters in CAD-CT colonography

    Full text link
    The aim of this paper is to present the development of a synthetic phantom that can be used for the selection of optimal scanning parameters in computed tomography (CT) colonography. In this paper we attempt to evaluate the influence of the main scanning parameters including slice thickness, reconstruction interval, field of view, table speed and radiation dose on the overall performance of a computer aided detection (CAD)–CTC system. From these parameters the radiation dose received a special attention, as the major problem associated with CTC is the patient exposure to significant levels of ionising radiation. To examine the influence of the scanning parameters we performed 51 CT scans where the spread of scanning parameters was divided into seven different protocols. A large number of experimental tests were performed and the results analysed. The results show that automatic polyp detection is feasible even in cases when the CAD–CTC system was applied to low dose CT data acquired with the following protocol: 13 mAs/rotation with collimation of 1.5 mm × 16 mm, slice thickness of 3.0 mm, reconstruction interval of 1.5 mm, table speed of 30 mm per rotation. The CT phantom data acquired using this protocol was analysed by an automated CAD–CTC system and the experimental results indicate that our system identified all clinically significant polyps (i.e. larger than 5 mm)