1,721,008 research outputs found

    Retinal Blood Vessel Caliber Estimation for Optical Coherence Tomography Angiography Images Based on 3D Superellipsoid Modeling

    No full text
    Changes of retinal blood vessel calibers may reflect various retinal diseases and even several nonretinal diseases. We propose a new method to estimate retinal vessel calibers from 3D optical coherence tomography angiography (OCTA) images based on 3D modeling using superellipsoids. Taking advantage of 3D visualization of the retinal tissue microstructures in vivo provided by OCTA, our method can detect retinal blood vessels precisely, estimate their calibers reliably, and show the relative flow speed visually.

    Feature issue introduction: ultrafast optical imaging

    Get PDF
    This feature issue of Optics Express collects 20 articles that report the most recent progress of ultrafast optical imaging. This review provides a summary of these articles that cover the spectrum of ultrafast optical imaging, from new technologies to applications

    Robust and easy-to-operate stretched-pulse mode-locked wavelength-swept laser with an all-polarization-maintaining fiber cavity for 10 MHz A-line rate optical coherence tomography

    No full text
    We demonstrate robust and easy-to-operate stretched-pulse mode-locked laser (SPML) architectures using all-polarization-maintaining fiber laser cavities. Because of the polarization-maintaining construction, the laser performance is unaffected by mechanical perturbation on the cavity fibers. The lasers automatically initiate linear-in-wavenumber sweeps across 100 nm centered at 1290 nm with a 10 MHz repetition rate. OCT imaging with a sensitivity of 98 dB and a single-sided 6 dB coherence length of 2.5 mm is demonstrated. OCT angiography of a mouse brain that visualized three-dimensional cerebral microvasculature over a field of 1.5 mm × 1.5 mm (398 A-lines × 380 B-scans) at a rate of 5.26 volumes per second is also presented. The robust all-PMF SPML lasers are a turnkey, high-performance source for ultrahigh-speed OCT imaging

    Sub-diffusion flow velocimetry with number fluctuation optical coherence tomography

    No full text
    We show number fluctuations dynamic light scattering optical coherence tomography (OCT) for measuring extremely slow, sub-diffusion flows of dilute particle suspensions. Our method removes the minimum measurable velocity limitation of conventional correlation-based or phase-resolved Doppler OCT, set by flowing particles’ Brownian motion. Our technique works for any Doppler angle, is applicable to 2D flow imaging with scanning OCT systems and can be used to determine concentration of particles under flow.ImPhys/Kalkman groupImPhys/Computational Imagin

    Wide-field computational cellular-resolution imaging of the human retina using multi-MHz phase-stable SS-OCT

    No full text
    Three-dimensional (3D) cellular-resolution imaging of the living human retina over a large field of view would bring a great impact in clinical ophthalmology, potentially finding new biomarkers for early diagnosis and improving the pathophysiological understanding of ocular diseases. While hardware-based and computational adaptive optics (AO) optical coherence tomography (OCT) have been developed to achieve cellular-resolution retinal imaging, these approaches support limited 3D imaging fields and their high cost and their intrinsic hardware complexity limit their practical utility. Here, we demonstrate 3D depth-invariant cellular-resolution imaging of the living human retina over a 3-mm × 3-mm field of view using the intrinsically phase-stable multi-MHz retinal swept-source OCT and tailored computational defocus and aberration correction methods. Single-acquisition imaging of photoreceptor cells, retinal nerve fiber layer, and retinal capillaries is presented across unprecedented imaging fields. By providing wide-field 3D cellular-resolution imaging in the human retina using a standard point-scan architecture routinely used in the clinic, this platform proposes a strategy for expanded utilization of high-resolution retinal imaging in both research and clinical settings

    Computational 3D resolution enhancement for optical coherence tomography with a narrowband visible light source

    No full text
    Phase-preserving spectral estimation optical coherence tomography (SE-OCT) enables combining axial resolution improvement with computational depth of focus (DOF) extension. We combine SE-OCT with interferometric synthetic aperture microscopy (ISAM) to obtain a high 3D resolution over a large depth range with a narrow bandwidth visible light super-luminescent diode (SLD). SE-OCT gives a five times axial resolution improvement to 1.5 micrometer. The combination with ISAM gives a sub-micron lateral resolution over a 300 micrometer axial range, 12 times the conventional DOF. The results show that phase-preserving SE-OCT is sufficiently accurate for coherent post-processing, enabling the use of cost-effective SLDs in the visible light range for high spatial resolution OCT.ImPhys/Computational ImagingImPhys/Kalkman grou

    Wide‐Field Three‐Dimensional Depth‐Invariant Cellular‐Resolution Imaging of the Human Retina

    No full text
    Three-dimensional (3D) cellular-resolution imaging of the living human retina over a large field of view will bring a great impact in clinical ophthalmology, potentially finding new biomarkers for early diagnosis and improving the pathophysiological understanding of ocular diseases. While hardware-based and computational adaptive optics (AO) optical coherence tomography (OCT) have been developed to achieve cellular-resolution retinal imaging, these approaches support limited 3D imaging fields, and their high cost and intrinsic hardware complexity limit their practical utility. Here, this work demonstrates 3D depth-invariant cellular-resolution imaging of the living human retina over a 3 x 3 mm field of view using the first intrinsically phase-stable multi-MHz retinal swept-source OCT and novel computational defocus and aberration correction methods. Single-acquisition imaging of photoreceptor cells, retinal nerve fiber layer, and retinal capillaries is presented across unprecedented imaging fields. By providing wide-field 3D cellular-resolution imaging in the human retina using a standard point-scan architecture routinely used in the clinic, this platform proposes a strategy for expanded utilization of high-resolution retinal imaging in both research and clinical settings.

    Progress on adaptive optics for multimodal OCT and confocal microscopy

    Get PDF
    We present our progress on image-guided (sensor-less) adaptive optics for multi-modal imaging of retinal tissue using high numerical aperture OCT and confocal microscopy using a custom developed instrument. Images of ex vivo tissues are compared to data acquired in vivo

    Speed detection to suppress motion artifacts (MA) in laser speckle contrast imaging (LSCI)

    Get PDF
    Laser speckle contrast imaging (LSCI) is an optical technique for noninvasive assessment of microcirculatory blood flow. LSCI has a broad application in medicine including dermatology. Since laser speckles are the basis for this imaging modality, any external motions during a measurement from both patient and operator affect the blood flow images. This challenge is called motion artefacts (MA). Here, we propose a complete procedure for analysis of speckles, that is, pre-segmentation, segmentation, motion detection, spatial alignment, perfusion map calculation and MA suppression. The handheld perfusion imager (HAPI) operated in both handheld and mounted schemes, has been used for measurements on 14 psoriasis subjects. The advantage of HAPI is use of a single monochromatic camera for both speckle imaging and motion detection. We make use of the black marker dots (made by the clinical investigator to determine visual psoriasis lesion boundary) for calculation of two-dimensional displacements of HAPI during each measurement (i.e. on-surface displacements). These on-surface displacements are integrated to translate each speckle image back to the initial position at the start of the measurement (i.e. spatial alignment). Furthermore, in handheld measurements, MA corrected blood flow maps (also called perfusion maps) are formed by extrapolation of a linear fit from local perfusion versus detected speed to the zero speed, that is, a value ideally always lower than the local mean perfusion. We show that our MA suppression technique makes handheld perfusion maps more similar to the associated mounted perfusion maps in term image histograms and mean values.</p
    corecore