174 research outputs found
Epilepsy? Video monitoring of long QT syndrome-related aborted sudden death
status: Publishe
Implantable cardioverter/defi brillator interventions in primary prevention: do current implantation criteria really predict ICD interventions?
Adenosine-induced ventricular asystole or rapid ventricular pacing to enhance three-dimensional rotational imaging during cardiac ablation procedures
Rotational angiography with digital three-dimensional reconstruction (3DRA) allows per-procedural 3D imaging to facilitate cardiac ablation procedures. We developed a new approach that allows per-procedural 3D imaging of the atria and ventricles with a single C-arm rotation, combining higher 3D image quality with a lower contrast and radiation dose.status: Publishe
Unifocal Right-Sided Ablation Treatment for Neurally Mediated Syncope and Functional Sinus Node Dysfunction Under Computed Tomographic Guidance.
BACKGROUND: Biatrial, extensive, and complex ablation strategies have been published for the treatment of neurally mediated syncope, sinus node dysfunction, and functional atrioventricular block. We have developed a less extensive and more specific approach compared with previously published cardioneuroablation strategies, called cardioneuromodulation. It is based on tailored vagolysis of the sinoatrial node through partial ablation of the anterior right-ganglionated plexus, preferentially through a right-sided approach. METHODS: Patients with syncope were enrolled between December 2016 and December 2017. They were assigned to group A if they had a positive head-up tilt test and to group B if they presented with a pause ≥3 seconds. The area to target during cardio-neuromodulation was designed offline on a computed tomographic scan. Slow heart rates and pauses were compared during 24-hour rhythm registration at baseline, at 1-month follow-up, and 6-month follow-up. Syncope burden was assessed before the procedure and at 3- and 6-month follow-up. RESULTS: Twenty patients underwent cardio-neuromodulation through a right-sided approach (12 in group A, 8 in group B). The first application of radiofrequency energy led to a P-P interval shortening >120 ms in all 20 patients. After a mean±SD ablation time of 7±4 minutes and mean ablated surface area of 11±6 mm2 , the P-P interval shortened by 219±160 ms (P<0.001). The number of beats <50/min during 24-hour rhythm registration was reduced by a median of 100% at 6-month follow-up (P<0.001). Syncope burden was reduced by 95% at 6-month follow-up (P<0.001). CONCLUSIONS: These data indicate that cardio-neuromodulation, through a right-sided and computed tomographic–guided procedure, is safe, fast, and highly reproducible in preventing inappropriate functional sinus bradycardia and syncope recurrence
Effect of pacing and mexiletine on dispersion of repolarisation and arrhythmias in DeltaKPQ SCN5A (long QT3) mice
OBJECTIVE: It has been suggested that both pacing and treatment with mexiletine may reduce torsade de pointes (TdP) arrhythmias in patients with long QT syndrome 3 (LQT3), but it is not fully understood how these interventions could prevent TdP. We therefore studied the effects of pacing and mexiletine in mice with a heterozygous knock-in DeltaKPQ SCN5A(Delta/+) deletion (SCN5A-Tg), a murine LQT3 model.METHODS: Three right and left ventricular monophasic action potentials (MAPs) were simultaneously recorded in Langendorff-perfused hearts of SCN5A-Tg and wild type (WT) littermates. AV block was induced, and pacing was performed at baseline and during mexiletine infusion (4 microg/ml). MAP recordings were analysed for action potential duration (APD), APD dispersion, and early afterdepolarisations (EADs) and related to spontaneous arrhythmias.RESULTS: After inducing AV block, SCN5A-Tg hearts were bradycardic [SCN5A-Tg 532+/-60 vs. WT 284+/-48 ms cycle length (CL, mean+/-S.E.M., P<0.05(*))]. EADs occurred in 16/18, and polymorphic ventricular tachycardia (pVT) in 11/18 SCN5A-Tg but not in 19 WT. SCN5A-Tg had longer APD than WT hearts*. At CL of 200 ms and longer, APD dispersion was higher in SCN5A-Tg [dispersion (APD70): 12+/-3 ms vs. 5+/-2 ms at CL=200 ms*], and increased to 35+/-4 ms* directly prior to pVT episodes. Sudden rate accelerations initially increased APD dispersion due to EADs and APD alternans in SCN5A-Tg, but pacing then reduced APD dispersion. Pacing suppressed (n=9/9) and prevented (n=49/50) pVT. Mexiletine shortened APD at long CL*, and suppressed pVT (n=4/5*), but did not prevent pVT during normal rhythm.CONCLUSIONS: Bradycardia, increased dispersion of APD and EADs provoke ventricular ectopy and pVT in SCN5A-Tg hearts. Ventricular pacing reduces APD dispersion, suppresses EADs and prevents pVT in SCN5A-Tg hearts. These effects provide a pathophysiological rationale for pacing in LQT3.</p
Durable Physiological Changes and Decreased Syncope Burden 12 Months After Unifocal Right-Sided Ablation Under Computed Tomographic Guidance in Patients With Neurally Mediated Syncope or Functional Sinus Node Dysfunction
[Figure: see text].sponsorship: The study is being supported by grants from Biosense Webster, Biotronik, and Abbott. The companies had no role in the design of the study or in the collection or management of the data or in the writing of the manuscript. (Biosense Webster, Biotronik, Abbott)status: Publishe
Abrupt rate accelerations or premature beats cause life-threatening arrhythmias in mice with long-QT3 syndrome
Deletion of amino-acid residues 1505-1507 (KPQ) in the cardiac SCN5A Na(+) channel causes autosomal dominant prolongation of the electrocardiographic QT interval (long-QT syndrome type 3 or LQT3). Excessive prolongation of the action potential at low heart rates predisposes individuals with LQT3 to fatal arrhythmias, typically at rest or during sleep. Here we report that mice heterozygous for a knock-in KPQ-deletion (SCN5A(Delta/+)) show the essential LQT3 features and spontaneously develop life-threatening polymorphous ventricular arrhythmias. Unexpectedly, sudden accelerations in heart rate or premature beats caused lengthening of the action potential with early afterdepolarization and triggered arrhythmias in Scn5a(Delta/+) mice. Adrenergic agonists normalized the response to rate acceleration in vitro and suppressed arrhythmias upon premature stimulation in vivo. These results show the possible risk of sudden heart-rate accelerations. The Scn5a(Delta/+) mouse with its predisposition for pacing-induced arrhythmia might be useful for the development of new treatments for the LQT3 syndrome.status: Publishe
Novel lamin A/C mutations in idiopathic dilated cardiomyopathy and/or conduction disease
Multielectrode pulmonary vein isolation versus single tip wide area catheter ablation for paroxysmal atrial fibrillation
Background - Single-shot ablation techniques may facilitate safe and simple pulmonary vein isolation to treat paroxysmal atrial fibrillation. Multielectrode pulmonary vein isolation versus single tip wide area catheter ablation-paroxysmal atrial fibrillation is the first multinational, multicenter, prospective, noninferiority randomized clinical trial comparing multielectrode-phased radiofrequency ablation (MEA) to standard focal irrigated radiofrequency ablation (STA) using 3-dimensional navigation. Methods and Results - Patients with paroxysmal atrial fibrillation were randomized to MEA (61 patients) or STA (59 patients). Preprocedure transesophageal echocardiogram and computed tomography/magnetic resonance imaging (also 6-month postprocedure) were performed. Mean age was 57 years, 25% female sex, BMI was 28, CHA 2 DS 2 -VASc score was 0 to 1 in 82%, 8% had previous right atrial ablation, whereas all had at least 1 antiarrhythmic drug failure. The MEA group had significantly shorter mean procedure time (96±36 versus 166±46 minutes, P50%. Freedom of atrial fibrillation for MEA and STA was 86.4% and 89.7% at 6 months, dropping to 76.3% and 81.0% at 12 months. Conclusions - In this multicenter, randomized clinical trial, MEA and STA had similar rates of single-procedure acute pulmonary vein isolation without serious adverse events in the first 30 days. MEA had slightly lower long-term arrhythmia freedom, but showed marked and significantly shorter procedure, fluoroscopy, and radiofrequency energy times
- …
