4 research outputs found

    Impact of patient positioning on radiotherapy dose distribution: An assessment in parotid tumor

    Get PDF
    Purpose: We intended to study the impact of patient positioning on the dose distribution within target volume and organs at risk in patients with parotid malignancies treated with 3D conformal radiotherapy (3D-CRT) with photon wedge pair (WP) or intensity modulated radiotherapy (IMRT).Methods: Three patients with a non-Hodgkin’s lymphoma of the right parotid gland were consecutively immobilized using thermoplastic cast in 2 positions: supine with head in neutral position (HN) and with head turned 90° to the left side (HT). Images for treatment planning purpose were acquired in both positions. For both positions, photon WP plans and 5 field IMRT plans were generated, after contouring clinical target volume (CTV), planning target volume (PTV= CTV + 5 mm margin) and organs at risk (OAR). All plans were evaluated for target coverage and dose to OARs.Results: Both CTV and PTV were apparently larger in HN compared with HT (31.76±8.89 cc, 30.31±7.83 cc and 62.49±19.01 cc, 58.89±15.33 cc) respectively. The CI value for PTV was slightly better for HT compared to HN position in both the WP and IMRT plans. The homogeneity was comparable in both the head positions in case of WP plan. The mean HI of PTV was increased in case of IMRT plan at HT versus HN position (1.108 vs. 1.097). A change in head position from HN to HT with wedge pair plan resulted in a reduction of brainstem Dmax and Dmean. Lesser dose was observed in HN position for contralateral parotid. A difference of 0.9 Gy in the average Dmax to spinal cord was seen. The values of Dmean to mandible, oral cavity, ipsilateral and contralateral cochlea were higher in the HT position. A change in head position from HN to HT with IMRT plan resulted in a dose reduction in average Dmax to brainstem. The spinal cord Dmax increased at the HT position by 1.2 Gy. The dose to contralateral parotid and cochlea was comparable in both the positions. However, the Dmean to oral cavity was reduced at HT position. Whereas for IMRT versus wedge pair plan at head neutral position average Dmean to the contralateral parotid was reduced with the IMRT plan. A considerable reduction in Dmax to spinal cord and Dmean to ipsilateral cochlea was observed. A slight increase in average Dmax to brainstem and was observed with the IMRT plan. The doses to the remaining OARs were lesser in case of IMRT plan. For IMRT versus wedge pair plan at head tilt position slight increase in average Dmax to brainstem was observed in case of IMRT plan. A considerable reduction in Dmax to spinal cord and Dmean to ipsilateral cochlea was observed. The doses to the remaining OARs were reduced with IMRT plan.Conclusion: Change in head position from neutral to 90° contralateral tilt for wedge pair plan in parotid tumor may considerably reduce dose to the brainstem and spinal cord with a modest increase in dose to mandible, oral cavity, contralateral parotid, and bilateral cochlea. The alteration in head position has minimal impact on IMRT planning

    Influence of collimator rotation on dose distribution and delivery in intensity modulated radiation therapy for parotid cancer

    Get PDF
    Purpose: To evaluate the influence of collimator rotation in IMRT planning with respect to the target coverage and dose to critical structures. In addition, the delivery efficiency of desired fluence with collimator rotation is assessed.Methods: The computed tomography (CT) datasets of 5 patients with parotid cancer were employed for this study. Dynamic IMRT plans were generated with a dose prescription of 60 Gy in 30 fractions. IMRT plans were generated with five unilateral fields using 6MV X-rays. Four different plans were generated for each patient by keeping the collimator angle at 0, 30, 60, and 90 degree. All plans were analyzed using dose volume histogram. Conformity index (CI) and heterogeneity index (HI) were calculated. The total monitor units (MU) required to deliver one fraction were noted and compared. To verify the delivery efficiency; the measured fluence on IBA I’mRT MatriXX ionization chamber array detector was compared with the TPS dose plan with 2D gamma evaluation.Results: There is not much difference in the PTV Dmax and Dmean with respect to the different collimator angles. The PTV coverage is best at collimator angle of 0 degree. A slight reduction in CI was observed with plans at other collimator angles as compared to 0 degree. The HI values were almost similar for plans with collimator angle 0, 30, and 60 degree. The plan with 90 degree collimator showed a slightly higher heterogeneity for the PTV. A slight reduction in the average Dmax to spinal cord was observed for the plan with collimator angle 30 degree as compared to other angles whereas maximum value of Dmax to spinal cord was at collimator angle 60 degree. No clinically relevant difference was observed among the plans with respect to brainstem and mandible Dmax. An increase in average of oral cavity Dmax and Dmean was observed for collimator angle 60 and 90 degree as compared to collimator angle 0 and 30 degree. Not much difference was observed with respect to Dmax and Dmean for contralateral parotid and cochlea with plans at different collimator angles. A decrease in MU required to deliver a fraction was observed for the plan with collimator angle 30 degree as compared to other angles. The plan with 90 degree collimator required maximum MU. The 2D γ index evaluation of planned and delivered fluence showed almost similar results for plans with different collimator angles.Conclusion: An individual case-specific collimator rotation may aid in achieving the desired dose distribution and relative sparing of critical structures in IMRT.  

    Effect of statistical uncertainty on Monaco Monte-Carlo dose calculation

    No full text
    Purpose: The aim of this study is to evaluate influence of statistical uncertainty on Monte-Carlo dose calculation of Monaco 5.11 treatment planning system (TPS).Methods: Phantom with contoured C-Shape structure set was downloaded from AAPM website provided with TG119 report. VMAT plan was created for C-Shape test case using Monaco TPS for 6 MV Elekta Versa-HD linear-accelerator. Dose prescription and constraints were as per TG119. After optimizations, C-Shape plan was calculated with different statistical-uncertainty (i) 0.5%, 1.0%, 3.0% and 5.0% per control point and (ii) 0.5%, 1.0%, 3.0% and 5.0% per calculation. Base plan was calculated with 0.5% per control point.Results: Variations in PTV doses for different statistical-uncertainties with respect to 0.5% per control point were within PTV-D95: 82 cGy(1.64%); PTV-D10: 14.8 cGy(0.28%); Core-D10: 3.7 cGy(0.15%). MU required to deliver a plan (920 MU) were observed same with different statistical-uncertainty. Calculation time increases with decrease in statistical-uncertainty due to more number of histories. 2D-Gamma pass rate was ranging from 98.1% to 98.9% for analyzed statistical-uncertainties. Statistical-uncertainty 0.5% per control point showed higher Gamma pass-rate (98.9%).Conclusion: Minor variation (<1.64%) in dose volume parameters was observed with different statistical-uncertainties, whereas Monitor unit remain same. 3.0% per control point and 0.5% per calculation resulted in almost similar results and found optimal with reasonable calculation time in terms of plan quality and delivery accuracy (gamma pass-rate)
    corecore