1,720,967 research outputs found
APPLICAZIONE SPERIMENTALE DI VASI UMANI DECELLULARIZZATI DI PICCOLO CALIBRO
Tissue engineering mean a wide field of science application in searching the substitusion by different process of damaged human tissue. The main intent is to obtain scaffold that can perfectly mimic the structural and functional characteristics of damaged tissues or organs. In the field of vascular graft numerous studies were conducted to obtain suitable tissue that could supplant the use of autologous bypassor even the littlest vessel employed in microsurgery. Over the years, various solutions have been proposed. The use of resorbable or non-resorbable vascular synthetic conduits, associated or not to stem cells and growth factors, small-caliber decellularized vessels and scaffold-free methods have been described in the literature. First, our study has produced experimental animal models in which a section of the rabbit femoral vessels was replaced by small caliber (inner diameter < 6 mm) human decellularized vessel.
Materials and methods
Two arteries and two human veins of small caliber (< 6 mm) obtained by upper arm lesions not suitable for surgical procedure were withdrawn and subjected to a process of decellularization according to a modified Sheridan’s protocol. The effectiveness of the process was shown in vitro with histological, immunohistochemical, ultrastructural, and qualitative and quantitative analysis of DNA. Mechanical testing and functional ecodoppler in vivo were also performed. Decellularized vessels were implanted in vivo in rabbit femoral vessels. The patency was verified, in vivo, at time 0, 10 and 20 minutes later. After 30 days for vein implants and 10 and 40 days for artery implants, the rabbits were sacrificed. The patency of grafts, the inflammatory process and re-endothelialization was tested with histological and immunophenotypical analysis. At the same time we analyzed also synthetic vessel as control , after two weeks of implantation.
Results
The various assays of decellularized vessels, in vitro, demonstrated the success of the process. The cellular component was eliminated without altering the composition and three-dimensional structure of extra cellular matrix. It was also confirmed by mechanical testing. The scaffolds were implanted successfully in all models and the patency was maintained until animals’ sacrifice, as also documented by ecocolordoppler evaluation. The histological and immunophenotypical analysis of taken scaffolds showed a minimal inflammatory process, the maintenance of the extracellular matrix structure and the wall and luminal surface re-cellularization. The syntethic vessel demonstrate complete thrombosis.
Conclusions
The adjustments made to the decellularization protocol proposed by Sheridan helped to keep acceptable length of the process maintaining the same effectiveness. Non-use of endothelial stem cells reduced costs even if, for longer grafts the use of cells to improve biocompatibility seems to be necessary.
The histological studies on withdrawn grafts have demonstrated a minimal presence of inflammatory processes, a complete patent in two weeks till eight weeks and the presence of a process of re-cellularization. The excellent biocompatibility of implanted scaffolds suggest the possibility of a subsequent application in clinical microvascular field and, in the future, for the establishment of a tissue bank to find substitutes with suitable caliber and length. Additional animal testing, with long time survival, mechanical and histological analysis are definitely essential to determine the effectiveness of these implants and think of a possible clinical trials
"Synchronous" multifocal necrotizing fasciitis
Background: Necrotizing fasciitis (NF) is an infection of the soft tissue, and is fatal if not promptly and aggressively treated. Although it is rare, it is not exceptional; nevertheless, its presentation may be misleading and may delay the diagnosis. We highlight the possible synchronous development of NF in multiple noncontiguous areas. Case Report: A 44-year-old diabetic man with no history of trauma complained of nonspecific lower back pain, which he treated with analgesics and oral antibiotics. Erythema at the left arm appeared, and the general condition worsened. The patient was admitted to the Emergency Department, and NF was diagnosed at the right gluteus and left arm. Conclusion: "Synchronous" multifocality is not an expected presentation of NF, and it complicates the diagnosis and delays treatment, with a potentially negative impact on outcome. (C) 2013 Elsevier Inc
Alternative conduits for microvascular anastomoses
Thrombotic events in vascular substitutes are the main cause of obliteration of most microvascular prostheses and subsequent failure of microvascular anastomoses. The development of new biomaterials for vascular replacement aims to obtain an ideal graft for microvascular surgery. Completely bioresorbable vascular prostheses with the capacity to induce regeneration and growth of a new vascular segment seem to overcome the limitations of contemporary artificial prostheses, mostly made of artificial materials and lacking the capacity to grow and be remodeled. Autologous vessels are currently the most used material for small-diameter arterial replacement. Immune acceptance is a major advantage offered by this technique, but the time required is a limitation in emergency surgery. The need for a prosthetic graft that would have the same properties as a small-diameter conduit has led investigators to pursue many avenues in vascular biology. This article details the development of microvascular synthetic prostheses, clarifying the current status and the future aims
Succesfull recellularization of human tendon scaffolds using adipose-derived mesenchymal stem cells
Comparison of reasorbeable mini anchor versus non reasorbeable: histological evaluation in an experimental rabbit mode
Purpose. Experimental animal study to evaluate the osseo integration, inflammatory response, dislocation and the reabsorption timing of the reasorbeable Mitek® mini anchor, in comparison with the non reasorbeable titanium based.
Methods. Twenty rabbits were used: divided into two groups of ten. Each animal underwent sectioning and reinsertion of the Achilles tendon bilaterally, using a reasorbeable mini anchor on one side and a controlateral non reasorbeable mini anchor. The first group was sacrificed after 40 days and the other after 120 days. The bone tendon complex was subjected to histological study.
Results. No histological and statistical significative difference were observed in each group, with a lower inflammation response in the reasorbeable implant. Electronic microscopy evaluation demonstrates good stability of the implant in each group. At day 120 the reasorbeable anchors were not yet disappeared.
Conclusion. Reasorbeable Mitek mini anchors are to be considered to guarantee a similar response and similar bone stability than non reasorbeable ones
The role of collagenase in treatment of low and moderate Dupuytren disease: a three years follow up pf 80 patients
Ricostruzione della parete addominale con scaffold decellularizzati: studio sperimentale
- …
