1,354,822 research outputs found
Optical coherence tomography and scanning laser ophthalmoscopy: Approaches to dual-channel retinal tissue imaging
We report a Talbot bands-based optical coherence tomography (OCT) system capable of producing longitudinal B-scan OCT images and en-face scanning laser ophthalmoscopy (SLO) images of the human retina in-vivo, with various degrees of simultaneity
Optical coherence tomography in archaeological and conservation science - a new emerging field
There has been a long tradition of applying biomedical imaging techniques to the examination of historical artefacts, owing to similar demands for non-invasive methods in both fields. Optical Coherence Tomography (OCT) is no exception. We review the achievements on OCT applications to art conservation and archaeology since the publication of the first papers in 2004. Historical artefacts include a much broader range of materials than biological tissues, hence presenting a greater and somewhat different challenge to the field of OCT. New results will be presented to illustrate the various applications of OCT including both qualitative and quantitative analysis
Akinetic Tuneable Optical Sources with Applications
Optical Coherence Tomography (OCT) is a modern, non-invasive imaging technique in biomedical research and medical diagnostics. It was initially developed for clinical applications in ophthalmology, providing high-resolution, cross-sectional images of the retina, retinal nerve fibre layer and the optic nerve head. Today, OCT is used for in vivo imaging of almost every type of tissue and it also branched out in fields outside medicine, like industrial or pharmaceutical applications.
OCT is a continuously improving imaging technique, benefiting from the development of advanced optical components and broadband optical sources. The objective of the work presented in the thesis was the development of both short and, respectively, long cavity akinetic optical devices, employing several types of dispersive optical fibre components in the cavity, like chirped fibre Bragg gratings, single mode or dispersion compensating fibre, and actively radio-frequency tuned semiconductor optical amplifiers, used as gain media. The use of external modulators, like Fabry-Perot assemblies, rotating mirrors and other mechanical devices is therefore completely eliminated, while versatility is added in the control of the coherence length, output bandwidth, repetition rate and power.
The short cavity source was developed in the 1060 nm region, the output power and bandwidth showing a slow decay with the increase of repetition rate up to 250 kHz. Without any booster, the power achieved was 2 mW at 100 kHz.
A novel dual-mode-locking mechanism was developed in order to tune an akinetic swept source based on dispersive cavities at a repetition rate close to, but different from the inverse of the cavity roundtrip. Several optical source configurations emitting in the 1060 nm or 1550 nm wavelength region were developed, characterised and tested in OCT applications. For the 1550 nm swept source employing a Faraday Rotating Mirror in a dispersive cavity, sweeping rates in the range of MHz were achieved, from 782 kHz to up to 5 times this value, with proportional decrease in the tuning bandwidth. Linewidths smaller than 60 pm and output powers exceeding 10 mW were measured. OCT topographic imaging was demonstrated.
The thesis ends with a proposed broadband investigation of microresonators written in silica glass employing akinetic optical sources at 1550 nm.
The work presented in this thesis resulted in several peer reviewed papers, one patent application and several conference presentations, listed after the final conclusions
Surface imaging of metallic material fractures using optical coherence tomography
We demonstrate the capability of optical coherence tomography (OCT) to perform topography of metallic surfaces after being subjected to ductile or brittle fracturing. Two steel samples, OL 37 and OL 52, and an antifriction Sn-Sb-Cu alloy were analyzed. Using an in-house-built swept source OCT system, height profiles were generated for the surfaces of the two samples. Based on such profiles, it can be concluded that the first two samples were subjected to ductile fracture, while the third one was subjected to brittle fracture. The OCT potential for assessing the surface state of materials after fracture was evaluated by comparing OCT images with images generated using an established method for such investigations, scanning electron microscopy (SEM). Analysis of cause of fracture is essential in response to damage of machinery parts during various accidents. Currently the analysis is performed using SEM, on samples removed from the metallic parts, while OCT would allow in situ imaging using mobile units. To the best of our knowledge, this is the first time that the OCT capability to replace SEM has been demonstrated. SEM is a more costly and time-consuming method to use in the investigation of surfaces of microstructures of metallic materials. © 2014 Optical Society of America
Towards an ultra-thin medical endoscope: multimode fibre as a wide-field image transferring medium
Multimode optical fibres are attractive for biomedical and industrial applications such as endoscopes because of the small cross section and imaging resolution they can provide in comparison to widely-used fibre bundles. However, the image is randomly scrambled by propagation through a multimode fibre. Even though the scrambling is unpredictable, it is deterministic, and therefore the scrambling can be reversed. To unscramble the image, we treat the multimode fibre as a linear, disordered scattering medium. To calibrate, we scan a focused beam of coherent light over thousands of different beam positions at the distal end and record complex fields at the proximal end of the fibre. This way, the inputoutput response of the system is determined, which then allows computational reconstruction of reflection-mode images. However, there remains the problem of illuminating the tissue via the fibre while avoiding back reflections from the proximal face. To avoid this drawback, we provide here the first preliminary confirmation that an image can be transferred through a 2x2 fibre coupler, with the sample at its distal port interrogated in reflection. Light is injected into one port for illumination and then collected from a second port for imaging
Long axial imaging range using conventional swept source lasers in optical coherence tomography via re-circulation loops
Typically, swept source optical coherence tomography (SS-OCT) imaging instruments are capable of a longer axial range than their camera based (CB) counterpart. However, there are still various applications that would take advantage for an extended axial range. In this paper, we propose an interferometer configuration that can be used to extend the axial range of the OCT instruments equipped with conventional swept-source lasers up to a few cm. In this configuration, the two arms of the interferometer are equipped with adjustable optical path length rings. The use of semiconductor optical amplifiers in the two rings allows for compensating optical losses hence, multiple paths depth reflectivity profiles (Ascans) can be combined axially. In this way, extremely long overall axial ranges are possible. The use of the recirculation loops produces an effect equivalent to that of extending the coherence length of the swept source laser. Using this approach, the achievable axial imaging range in SS-OCT can reach values well beyond the limit imposed by the coherence length of the laser, to exceed in principle many centimeters. In the present work, we demonstrate axial ranges exceeding 4 cm using a commercial swept source laser and reaching 6 cm using an “in-house” swept source laser. When used in a conventional set-up alone, both these lasers can provide less than a few mm axial range
Phase sensitive optical coherence microscopy for photothermal imaging of gold nanorods
We describe a swept source based phase sensitive optical coherence microscopy (OCM) system for photothermal imaging of gold nanorods (GNR). The phase sensitive OCM system employed in the study has a displacement sensitivity of 0.17 nm to vibrations at single frequencies below 250 Hz. We demonstrate the generation of phase maps and confocal phase images. By displaying the difference between successive confocal phase images, we perform the confocal photothermal imaging of accumulated GNRs behind a glass coverslip and behind the scattering media separately. Compared with two-photon luminescence (TPL) detection techniques reported in literature, the technique in this study has the advantage of a simplified experimental setup and provides a more efficient method for imaging the aggregation of GNR. However, the repeatability performance of this technique suffers due to jitter noise from the swept laser source
Use of a supercontinuum white light in evaluating the spectral sensitivity of the pupil light reflex
We assessed the spectral sensitivity of the pupillary light reflex in mice using a high power super continuum white light (SCWL) source in a dual wavelength configuration. This novel approach was compared to data collected from a more traditional setup using a Xenon arc lamp fitted with monochromatic interference filters. Irradiance response curves were constructed using both systems, with the added benefit of a two-wavelength, equivocal power, output using the SCWL. The variables applied to the light source were intensity, wavelength and stimulus duration through which the physiological output measured was the minimum pupil size attained under such conditions. We show that by implementing the SCWL as our novel stimulus we were able to dramatically increase the physiological usefulness of our pupillometry system
Mitigation of Speckle Noise in Optical Coherence Tomograms
Optical Coherence Tomography (OCT) is a promising high-resolution imaging technique that works based on low coherent interferometry. However, like other low coherent imaging modalities, OCT suffers from an artifact called, speckle. Speckle reduces the detectability of diagnostically relevant features in the tissue. Retinal optical coherence tomograms are of a great importance in detecting and diagnosing eye diseases. Different hardware or software based techniques are devised in literatures to mitigate speckle noise. The ultimate aim of any software-based despeckling technique is to suppress the noise part of speckle while preserves the information carrying portion of that. In this chapter, we reviewed the most prominent speckle reduction methods for OCT images to date and then present a novel and intelligent speckle reduction algorithm to reduce speckle in OCT images of retina, based on an ensemble framework of Multi-Layer Perceptron (MLP) neural networks
Combined Multiplanar Optical Coherence Tomography and Confocal Scanning Ophthalmoscopy
Podoleanu conducted and supervised the overall research which lead to the research, assembly and installation of imaging prototypes in two leading eye clinics in New York. Podoleanu was instrumental in the prototype installation as well as in collating first images from eyes with pathology produced using en-face OCT technology. (Impact Factor: 3.455
- …
