    Analytical methods for braided stents design and comparison with FEA

    Full text link
    Braiding technology is nowadays commonly adopted to build stent-like devices. Indeed, these endoprostheses, thanks to their typical great flexibility and kinking resistance, find several applications in mini-invasive treatments, involving but not limiting to the cardiovascular field. The design process usually involves many efforts and long trial and error processes before identifying the best combination of manufacturing parameters. This paper aims to provide analytical tools to support the design and optimization phases: the developed equations, based on few geometrical parameters commonly used for describing braided stents and material stiffness, are easily implementable in a worksheet and allow predicting the radial rigidity of braided stents, also involving complex features such as multiple twists and looped ends, and the diameter variation range. Finite element simulations, previously validated with respect to experimental tests, were used as a comparator to prove the reliability of the analytical results. The illustrated tools can assess the impact of each selected parameter modification and are intended to guide the optimal selection of geometrical and mechanical stent proprieties to obtain the desired radial rigidity, deliverability (minimum diameter), and, if forming processes are planned to modify the shape of the stent, the required diameter variations (maximum and minimum diameters)

    A Computational Model of Heat Loss and Water Condensation on the Gas-Side of Blood Oxygenators

    Full text link
    Clinical observation of condensation at the gas flow exit of blood oxygenators is a recurrent event during cardiopulmonary bypass. These devices consist of a bundle of hollow fibers made of a microporous membrane that allows the exchange of O2 and CO2. The fibers carry a gas mixture inside (intraluminal flow), while blood flows externally around them (extraluminal flow). Although different studies described this effect in the past, the specific role of the different sections of the device requires further analysis, and the total condensation rate remains unquantified. In this study, a closer look is taken at the transition of gas between the oxygenation bundle and the external room air. A method is proposed to estimate the total condensate output, combining computational fluid dynamics (CFD) of thermal distribution and a simplified 1D model of water vapor saturation of gas. The influence of a number of different parameters is analyzed, regarding material properties, environmental conditions, and clinical use. Results show that condensation rate could vary in a 30-fold range within reasonably small variations of the different variables considered

    The influence of systemic-to-pulmonary arterial shunts and peripheral vasculatures in univentricular circulations: Focus on coronary perfusion and aortic arch hemodynamics through computational multi-domain modeling

    No full text
    Initial palliation for univentricular hearts can be achieved via a systemic-to-pulmonary shunt (SPS). SPS configurations differ depending on the proximal anastomosis location, which might lead to dissimilar coronary and upper body perfusions. Mathematical modeling can be used to explore the local and global hemodynamic effects of the SPSs. In literature there are few patient-specific models of SPS that specifically address the influence of both the local and peripheral vasculature. In this study, multi-domain models of univentricular circulations were developed to investigate local hemodynamics and flow distribution in the presence of two shunt configurations. We also analyzed the relative impact of local and peripheral vascular resistances on coronary perfusion and flows through the upper aortic branches. A two-step approach was followed. First, two patient-specific models were based on clinical data collected from univentricular patients having different shunts and peripheral vasculatures. Each model coupled a three-dimensional representation of SPS, aortic arch (AA) and pulmonary arteries, with a lumped parameter model (LPM) of peripheral vasculature closing the circulatory loop. Then, two additional models of hypothetical subjects were created by coupling each customized LPM with the other patient's three-dimensional anatomy. Flow rates and pressures predicted by the patient-specific models revealed overall agreement with clinical data. Differences in the local hemodynamics were seen during diastole between the two models. Varying the three-dimensional models, while keeping an identical LPM, led to comparable flow distribution through the AA, suggesting that peripheral vasculatures have a dominant effect on local hemodynamics with respect to the shunt configuration

    Validation of the computational model of a coronary stent: a fundamental step towards in silico trials

    Full text link
    The proof of the reliability of a numerical model is becoming of paramount importance in the era of in silico clinical trials. When dealing with a coronary stenting procedure, the virtual scenario should be able to replicate the real device, passing through the different stages of the procedure, which has to maintain the atherosclerotic vessel opened. Nevertheless, most of the published studies adopted commercially resembling geometries and generic material parameters, without a specific validation of the employed numerical models. In this work, a workflow for the generation and validation of the computational model of a coronary stent was proposed. Possible sources of variability in the results, such as the inter-batches variability in the material properties and the choice of proper simulation strategies, were accounted for and discussed. Then, a group of in vitro tests, representative of the device intended use was used as a comparator to validate the model. The free expansion simulation, which is the most used simulation in the literature, was shown to be only partially useful for stent model validation purposes. On the other hand, the choice of proper additional experiments, as the suggested uniaxial tensile tests on the stent and deployment tests into a deformable tube, could provide further suitable information to prove the efficacy of the numerical approach