1,720,983 research outputs found

    Performance analysis of an innovative small-scale trigeneration plant with liquid desiccant cooling system

    No full text
    The paper deals with an innovative natural gas combined heat, cooling and power (CHCP) system with electrical, heating and cooling capacities of 126/220/210 kW, respectively. The trigeneration plant is composed of a cogenerator which uses an automotive derived gas fired internal combustion engine (ICE), coupled to a liquid LiCl–water desiccant cooling system which recovers heat from the flue gases and from the ICE cooling water. The paper describes the energetic and economic analyses of the plant and itmakes some evaluations of the effects of fuel and electric prices and of the subsides and plant costs on the economic indices of the system

    STUDIO E CARATTERIZZAZIONE DI RETI TERMICHE DISTRIBUITE

    No full text
    Il presente documento illustra le attività svolte in relazione all’Accordo di Programma tra il Dipartimento Energia DENERG del Politecnico di Torino e l’ENEA, per un’attività di ricerca dal titolo: “Studio e caratterizzazione di reti termiche distribuite”. Oggetto della collaborazione è stato l’approfondimento delle tematiche inerenti le reti termiche di teleriscaldamento, con focus sulle reti locali, analizzando i principali problemi tecnici, normativi ed economici caratteristici di tali tecnologie. Il fine di tali analisi può essere individuato nel tentativo di individuare soluzioni progettuali da proporre sia a strutture esistenti, sia a nuove installazioni, per rendere più efficienti le attuali infrastrutture. Nello specifico, è stato analizzato nel dettaglio un impianto di cogenerazione localizzato a Torino, asservito ad una rete di teleriscaldamento per la distribuzione dell’energia termica agli stabili residenziali del quartiere limitrofo. L’impianto vede inoltre la presenza di un assorbitore a bromuro di litio, per produrre energia frigorifera durante i mesi estivi, in assetto trigenerativo. Le indagini svolte hanno permesso inizialmente di determinare i parametri caratteristici di funzionamento dell’impianto, quali gli indici di performance energetica; sulla base di questi sono state individuate le attuali inefficienze di gestione, sia lato produzione, che lato distribuzione del calore. Si sono successivamente valutate le possibili ottimizzazioni nella conduzione dell’impianto, quali ad esempio la definizione di nuove strategie di controllo del cogeneratore, in grado di ridurre le perdite e ottimizzare le performance energetiche ed economiche derivanti. Le soluzioni migliorative ipotizzate sono state, infatti, corredate da un’analisi economica, in modo da valutare anche la effettiva fattibilità economica delle soluzioni ipotizzate. L’ultima parte dell’attività è stata focalizzata nell’analisi di un modello di simulazione di reti termiche, sviluppato su piattaforma Matlab Simulink dall’ENEA in collaborazione con l’Università “Sapienza” di Roma (Report RdS/2012/078 e RdS/2012/079). Sono stati implementati i necessari sviluppi software, volti a rendere il modello adatto a simulare la rete di quartiere analizzata in seno al presente studio. Tale attività ha consentito di arrivare ad una prima validazione del programma, basata sui dati di funzionamento reale dell’impianto ivi considerato. Alla luce delle evidenze emerse dallo studio, di particolare interesse potrebbe essere inoltre l’allestimento di un sistema di monitoraggio remoto dell’intero impianto, con il quale poter valutare in real-time le performance energetiche dei principali componenti dello stesso, e definire, conseguentemente, nuove strategie di controllo in grado di ridurre le perdite e aumentare la capacità di fornitura delle reti esistenti

    Dynamic parsimonious model and experimental validation of a gas microturbine at part-load conditions

    No full text
    The aim of this work is to present an analytical parsimonious model, developed with Matlab Simulink®, which, with computational simplicity and with only a few technical data as input, obtained easily from technical datasheets, is able to predict both the dynamic and steady state performances of a natural gas microturbine, at nominal point and at part-load conditions. Scaling techniques have been applied to the main components of the model, in order to allow a large range of plant sizes (20e200 kWel) to be simulated. The validation of the simulation code has been carried out by means of experimental data obtained from a commercial 100 kWel mGT installed at the Politecnico di Torino, whose experimental characterization was carried out by the Authors. The agreement of the simulated results with the experimental figures has resulted to be very good, considering the computational simplicity of the model. The main results of the study are presented in the pape

    Experimental tests of a small-scale microturbine with a liquid desiccant cooling system

    No full text
    In a trigeneration plant, the thermal energy recovered from the prime mover is exploited to produce a cooling effect. Although this possibility allows the working hours of the plant to be extended over the heating period, providing summer air conditioning through thermally activated technologies, it is rather difficult to find in the literature experimental data on trigeneration plants operation, and the availability of performance characteristics at off-design conditions is anyway limited. The paper has the aim of showing the experimental data of a real trigeneration system installed at the Politecnico di Torino (Turin, Italy), composed of a natural gas 100 kWel microturbine coupled to a liquid desiccant system. The data are presented for both cogeneration and trigeneration configurations, and for full and partial load operations. A energetic and economic performance assessment at rated power operation is presented, and compared with the partial load operation strategy. The primary energy savings are calculated through a widely accepted methodology, proposed by the European Union, and through another methodology, reported in literature, which seems to the Authors more suitable to describe the energetic performances of trigeneration plants

    Energetic operational assessment of two small-scale trigeneration plants

    No full text
    Trigeneration allows the thermal energy that is recovered from the prime mover of a cogeneration plant to be exploited to produce a cooling effect. In this way, when residential applications are considered, it is possible to extend the working hours of the plant over the heating period, providing the summer air conditioning. The paper is aimed at investigating the energetic performance of trigeneration, compared to cogeneration, dealing with the differences on prime mover efficiencies in the winter and the summer season. Two small-scale trigeneration plants have been considered: an internal combustion engine cogenerator capable of 126 kWel coupled to a liquid desiccant system, and a 100 kWel natural gas microturbine with an absorption chiller. The primary energy savings have been calculated, for both plant configurations, through a commonly accepted methodology proposed by the European Union, and through another methodology, reported in literature, which seems more appropriate to describe the energetic performances of trigeneration plants. A new performance indicator was then introduced by the Authors. The results are presented and discussed
    corecore