1,721,069 research outputs found

    Papadimitriou Konstantinos

    No full text

    CMOS weak-inversion log-domain glycolytic oscillator: a cytomimetic circuit example

    No full text
    This paper presents a 3?V, 1.21?W subthreshold log-domain circuit which mimics the oscillations observed during the biochemical process of glycolysis due to the phosphofructokinase enzyme. The proposed electronic circuit is able to simulate the dynamics of the glycolytic oscillator and represent the time-dependent concentration changes of the reactants and the products of the chemical process based on nonlinear differential equations which describe the biological system. By modifying specific circuit parameters, which correspond to certain chemical parameters, good agreement between the biochemical and electrical model results has been reached. The paper details the similarities between the equations that describe the biochemical process and the equations derived from the circuit analysis of a transistor and a source-connected linear capacitor, a topology also known as the Bernoulli Cell. With the use of the Bernoulli Cell formalism, the chemical equations which describe the biochemical system have been transformed into their electrical equivalents. The analog circuit, which implements the whole process, has been synthesised, and simulation results including Monte Carlo analysis are provided, in order to verify the robustness of the proposed circuit and to compare its dynamics with prototype biological behaviou

    An Assay System For Point-of-Care Diagnosis Of Tuberculosis using Commercially Manufactured PCB Technology

    No full text
    The data included in this file is provided in an excel format and provides the supporting data for the graphs in Figures 2 -6 in the paper: An Assay System of Point-of-care Diagnosis of Tuberculosis using commercially manufactured PCB Technology. Corresponding author Daniel Evans- University of Southampton. Accepted Manuscript 13/3/2017 by Scientific Reports - Nature.com</span

    An assay system for point-of-care diagnosis of tuberculosis using commercially manufactured PCB technology

    No full text
    Rapid advances in clinical technologies, detection sensitivity and analytical throughput have delivered a significant expansion in our knowledge of prognostic and diagnostic biomarkers in many common infectious diseases, such as Tuberculosis (TB). During the last decade, a significant number of approaches to TB diagnosis have been attempted at Point-of-Care (PoC), exploiting a large variation of techniques and materials. In this work, we describe an electronics-based Enzyme-Linked ImmunoSorbent Assay (eELISA), using a Lab-on-a-Printed Circuit Board (LoPCB) approach, for TB diagnosis based on cytokine detection. The test relies upon an electrochemical (amperometric) assay, comprising a high-precision bioinstrumentation board and amperometric sensors, produced exclusively using standard PCB manufacturing processes. Electrochemical detection uses standard Au and Ag electrodes together with a bespoke, low-power, multichannel, portable data-acquisition system. We demonstrate high-performance assay chemistry performed at microfluidic volumes on Au pads directly at the PCB surface with improved limit of detection (~10 pg/mL) over standard colorimetric ELISA methods. The assay has also been implemented in plasma, showing the utility of the system for medical applications. This work is a significant step towards the development of a low-cost, portable, high-precision diagnostic and monitoring technology, which once combined with appropriate PCB-based microfluidic networks will provide complete LoPCB platforms

    A sub-30 mpH resolution thin film transistor-based nanoribbon biosensing platform

    No full text
    We present a complete biosensing system that comprises a Thin Film Transistor (TFT)-based nanoribbon biosensor and a low noise, high-performance bioinstrumentation platform, capable of detecting sub-30 mpH unit changes, validated by an enzymatic biochemical reaction. The nanoribbon biosensor was fabricated top-down with an ultra-thin (15 nm) polysilicon semiconducting channel that offers excellent sensitivity to surface potential changes. The sensor is coupled to an integrated circuit (IC), which combines dual switched-capacitor integrators with high precision analog-to-digital converters (ADCs). Throughout this work, we employed both conventional pH buffer measurements as well as urea-urease enzymatic reactions for benchmarking the overall performance of the system. The measured results from the urea-urease reaction demonstrate that the system can detect urea in concentrations as low as 25 µM, which translates to a change of 27 mpH, according to our initial pH characterisation measurements. The attained accuracy and resolution of our system as well as its low-cost manufacturability, high processing speed and portability make it a competitive solution for applications requiring rapid and accurate results at remote locations; a necessity for Point-of-Care (POC) diagnostic platforms

    High-performance PCB-based capillary pumps for affordable Point-of-Care diagnostics

    Get PDF
    Capillary pumps are integral components of passive microfluidic devices. They can displace precise volumes of liquid, avoiding the need for external active components, providing a solution for sample preparation modules in Point-of-Care (PoC) diagnostic platforms. In this work, we describe a variety of high-performance capillary pump designs, suitable for the Lab-on-Printed-Circuit-Board technology (LoPCB). Pumps are fabricated entirely on Printed Circuit Board (PCB) substrates via commercially available manufacturing processes. We demonstrate the concept of LoPCB technology and detail the fabrication method of different architectures of PCB-based capillary pumps. The capillary pumps are combined with microfluidic channels of various hydraulic resistances and characterised experimentally for different micropillar shapes and minimum feature size. Their performance, in terms of flow-rate is reported. Due to the superhydrophilic properties of oxygen plasma treated FR-4 PCB substrate, the capillary pump flow-rates are much higher (138 μL/min, for devices comprising micropillar arrays without preceding microchannel) than comparable devices based on glass, silicon or other polymers. Finally, we comment on the technology’s prospects, such as incorporating more complicated microfluidic networks that can be tailored for assays

    Neuromorphic log-domain silicon synapse circuits obey Bernoulli dynamics: a unifying tutorial analysis

    Get PDF
    The field of neuromorphic silicon synapse circuits is revisited and a parsimonious mathematical framework able to describe the dynamics of this class of log-domain circuits in the aggregate and in a systematic manner is proposed. Starting from the Bernoulli Cell Formalism (BCF), originally formulated for the modular synthesis and analysis of externally linear, time-invariant logarithmic filters, and by means of the identification of new types of Bernoulli Cell (BC) operators presented here, a generalized formalism (GBCF) is established. The expanded formalism covers two new possible and practical combinations of a MOS transistor (MOST) and a linear capacitor. The corresponding mathematical relations codifying each case are presented and discussed through the tutorial treatment of three well-known transistor-level examples of log-domain neuromorphic silicon synapses. The proposed mathematical tool unifies past analysis approaches of the same circuits under a common theoretical framework. The speed advantage of the proposed mathematical framework as an analysis tool is also demonstrated by a compelling comparative circuit analysis example of high order, where the GBCF and another well-known log-domain circuit analysis method are used for the determination of the input-output transfer function of the high (4th) order topolog
    corecore