642 research outputs found
Framework for quantitative evaluation of 3D vessel segmentation approaches using vascular phantoms in conjunction with 3D landmark localization and registration
White matter fiber-based analysis of T1w/T2w ratio map
Purpose: To develop, test, evaluate and apply a novel tool for the white matter fiber-based analysis of T1w/T2w ratio maps quantifying myelin content. Background: The cerebral white matter in the human brain develops from a mostly non-myelinated state to a nearly fully mature white matter myelination within the first few years of life. High resolution T1w/T2w ratio maps are believed to be effective in quantitatively estimating myelin content on a voxel-wise basis. We propose the use of a fiber-tract-based analysis of such T1w/T2w ratio data, as it allows us to separate fiber bundles that a common regional analysis imprecisely groups together, and to associate effects to specific tracts rather than large, broad regions. Methods: We developed an intuitive, open source tool to facilitate such fiber-based studies of T1w/T2w ratio maps. Via its Graphical User Interface (GUI) the tool is accessible to non-technical users. The framework uses calibrated T1w/T2w ratio maps and a prior fiber atlas as an input to generate profiles of T1w/T2w values. The resulting fiber profiles are used in a statistical analysis that performs along-tract functional statistical analysis. We applied this approach to a preliminary study of early brain development in neonates. Results: We developed an open-source tool for the fiber based analysis of T1w/T2w ratio maps and tested it in a study of brain development
Improved registration of DCE-MR images of the liver using a prior segmentation of the region of interest
In Dynamic Contrast-Enhanced MRI (DCE-MRI) of the liver, a series of images is acquired over a period of 20 minutes. Due to the patient's breathing, the liver is subject to a substantial displacement between acquisitions. Furthermore, due to its location in the abdomen, the liver also undergoes marked deformation. The large deformations combined with variation in image contrast make accurate liver registration challenging. We present a registration framework that incorporates a liver segmentation to improve the registration accuracy. The segmented liver serves as region-of-interest to our in-house developed registration method called ALOST (autocorrelation of local image structure). ALOST is a continuous optimization method that uses local phase features to overcome space-variant intensity distortions. The proposed framework can confine the solution field to the liver and allow for ALOST to obtain a more accurate solution. For the segmentation part, we use a level-set method to delineate the liver in a so-called contrast enhancement map. This map is obtained by computing the difference between the last and registered first volume from the DCE series. Subsequently, we slightly dilate the segmentation, and apply it as the mask to the other DCE-MRI volumes during registration. It is shown that the registration result becomes more accurate compared with the original ALOST approach.ImPhys/Quantitative Imagin
Automatic estimation of retinal nerve fiber bundle orientation in SD-OCT images using a structure-oriented smoothing filter
Optical coherence tomography (OCT) yields high-resolution, three-dimensional images of the retina. A better understanding of retinal nerve fiber bundle (RNFB) trajectories in combination with visual field data may be used for future diagnosis and monitoring of glaucoma. However, manual tracing of these bundles is a tedious task. In this work, we present an automatic technique to estimate the orientation of RNFBs from volumetric OCT scans. Our method consists of several steps, starting from automatic segmentation of the RNFL. Then, a stack of en face images around the posterior nerve fiber layer interface was extracted. The image showing the best visibility of RNFB trajectories was selected for further processing. After denoising the selected en face image, a semblance structure-oriented filter was applied to probe the strength of local linear structure in a discrete set of orientations creating an orientation space. Gaussian filtering along the orientation axis in this space is used to find the dominant orientation. Next, a confidence map was created to supplement the estimated orientation. This confidence map was used as pixel weight in normalized convolution to regularize the semblance filter response after which a new orientation estimate can be obtained. Finally, after several iterations an orientation field corresponding to the strongest local orientation was obtained. The RNFB orientations of six macular scans from three subjects were estimated. For all scans, visual inspection shows a good agreement between the estimated orientation fields and the RNFB trajectories in the en face images. Additionally, a good correlation between the orientation fields of two scans of the same subject was observed. Our method was also applied to a larger field of view around the macula. Manual tracing of the RNFB trajectories shows a good agreement with the automatically obtained streamlines obtained by fiber tracking.ImPhys/Quantitative Imagin
Multi-voxel algorithm for quantitative bi-exponential MRI T<sub>1</sub> estimation
Quantification of the spin-lattice relaxation time, T1, of tissues is important for characterization of tissues in clinical magnetic resonance imaging (MRI). In T1 mapping, T1 values are estimated from a set of T1-weighted MRI images. Due to the limited spatial resolution of the T1-weighted images, one voxel might consist of two tissues, causing partial volume effects (PVE). In conventional mono-exponential T1 estimation, these PVE result in systematic errors in the T1 map. To account for PVE, single-voxel bi-exponential estimators have been suggested. Unfortunately, in general, they suffer from low accuracy and precision. In this work, we propose a joint multi-voxel bi-exponential T1 estimator (JMBE) and compare its performance to a single-voxel bi-exponential T1 estimator (SBE). Results show that, in contrast to the SBE, and for clinically achievable single-voxel SNRs, the JMBE is accurate and efficient if four or more neighboring voxels are used in the joint estimation framework. This illustrates that, for clinically realistic SNRs, accurate results for quantitative biexponential T1 estimation are only achievable if information of neighboring voxels is incorporated.Team Michel Verhaege
Intraoperative three-dimensional fluoroscopic cholangiography
Precise intraoperative assessment of the architecture of the biliary tree could reduce lesions to intra- or extrahepatic bile ducts. The aim of this study was to test feasibility of intraoperative three-dimensional imaging during liver resections. Isocentric C-arm fluoroscopy acquires three-dimensional images during a 190 degrees orbital rotation. The bile ducts were displayed three-dimensionally by realtime rotational projections or multiplanar reconstructions. The technique was established ex vivo in a preserved cadaveric human liver. Intraoperative three-dimensional cholangiography was performed in five patients with centrally located liver malignancies. Complete data acquisition in 3 patients depicted precise anatomical details of the architecture of the biliary tree up to third order divisions. Biliary imaging can be improved by the application of real-time intraoperative three-dimensional cholangiography. For the development of computer-aided navigation in hepatobiliary procedures, this technique could be an important prerequisite for defining landmarks of the liver in a three-dimensional space
Loosely coupled level sets for retinal layers and drusen segmentation in subjects with dry age-related macular degeneration
Optical coherence tomography (OCT) is used to produce high-resolution three-dimensional images of the retina, which permit the investigation of retinal irregularities. In dry age-related macular degeneration (AMD), a chronic eye disease that causes central vision loss, disruptions such as drusen and changes in retinal layer thicknesses occur which could be used as biomarkers for disease monitoring and diagnosis. Due to the topology disrupting pathology, existing segmentation methods often fail. Here, we present a solution for the segmentation of retinal layers in dry AMD subjects by extending our previously presented loosely coupled level sets framework which operates on attenuation coefficients. In eyes affected by AMD, Bruch’s membrane becomes visible only below the drusen and our segmentation framework is adapted to delineate such a partially discernible interface. Furthermore, the initialization stage, which tentatively segments five interfaces, is modified to accommodate the appearance of drusen. This stage is based on Dijkstra's algorithm and combines prior knowledge on the shape of the interface, gradient and attenuation coefficient in the newly proposed cost function. This prior knowledge is incorporated by varying the weights for horizontal, diagonal and vertical edges. Finally, quantitative evaluation of the accuracy shows a good agreement between manual and automated segmentation.ImPhys/Quantitative Imagin
Heritability analysis of surface-based cortical thickness estimation on a large twin cohort
The aim of this paper is to assess the heritability of cerebral cortex, based on measurements of grey matter (GM) thickness derived from structural MR images (sMRI). With data acquired from a large twin cohort (328 subjects), an automated method was used to estimate the cortical thickness, and EM-ICP surface registration algorithm was used to establish the correspondence of cortex across the population. An ACE model was then employed to compute the heritability of cortical thickness. Heritable cortical thickness measures various cortical regions, especially in frontal and parietal lobes, such as bilateral postcentral gyri, superior occipital gyri, superior parietal gyri, precuneus, the orbital part of the right frontal gyrus, right medial superior frontal gyrus, right middle occipital gyrus, right paracentral lobule, left precentral gyrus, and left dorsolateral superior frontal gyrus
A framework for incorporating DTI Atlas Builder registration into Tract-Based Spatial Statistics and a simulated comparison to standard TBSS
Tract-based spatial statistics (TBSS) is a software pipeline widely used in comparative analysis of the white matter integrity of groups of diffusion tensor imaging (DTI) datasets. However, several components of TBSS have been criticized over the years. Many of these criticisms stem, in part, from its white matter skeletonization and projection and the lack of directional data in its calculations. In addition, currently there exist no accepted, unbiased methods for comparing TBSS to its counterparts, and there is clearly a need for a more intuitive user-friendly software interface for running TBSS. In this study, I have altered existing diffusion atlas building software and integrated it into TBSS named DAB-TBSS (DTI Atlas Builder Tract-Based Spatial Statistics) by using advanced registration offered by DTI Atlas Builder and incorporating blurring into the skeletal projection step. Here, I also propose a framework for simulating population
differences for diffusion tensor imaging data, providing a more substantive means
of empirically comparing DTI group analysis programs such as TBSS.Bachelor of Scienc
Estimation of aortic valve leaflets from 3D CT images using local shape dictionaries and linear coding
Aortic valve (AV) disease is a significant cause of morbidity and mortality. The preferred treatment modality for severe AV disease is surgical resection and replacement of the native valve with either a mechanical or tissue prosthetic. In order to develop effective and long-lasting treatment methods, computational analyses, e.g., structural finite element (FE) and computational fluid dynamic simulations, are very effective for studying valve biomechanics. These computational analyses are based on mesh models of the aortic valve, which are usually constructed from 3D CT images though many hours of manual annotation, and therefore an automatic valve shape reconstruction method is desired. In this paper, we present a method for estimating the aortic valve shape from 3D cardiac CT images, which is represented by triangle meshes. We propose a pipeline for aortic valve shape estimation which includes novel algorithms for building local shape dictionaries and for building landmark detectors and curve detectors using local shape dictionaries. The method is evaluated on real patient image dataset using a leave-one-out approach and achieves an average accuracy of 0.69 mm. The work will facilitate automatic patient-specific computational modeling of the aortic valve
- …
