    A new hold-down device for seismic applications in CLT buildings: Design, testing, analytical and numerical assessment

    No full text
    An hold-down device was designed and tested experimentally for seismic applications (Seismic Hold-Down, SHD). The magnitude of axial strength as well as the up-lift displacement capacity is mainly oriented to cross-laminated-timber (CLT) buildings with medium-to-high ductility. There is consensus in the design practice of hold-down devices for promoting, as dissipative mechanism, flexural yielding of the dowel-type connectors (e.g. nails, screws) combined to timber's embedment. Few are the applications aiming at hold-down's optimization as it emerges from up-to-date literature review. In this framework, SHD was conceived such that tension break-out of steel was promoted at a reduced segment (fuse) of the vertical flange. In the context of capacity design, a convenient overstrength was assumed for other failure mechanisms, e.g. anchor's pullout, laterally-loaded steel-to-timber connection, shear-plug of timber. The mechanical response under axial load was consistently predicted by an application of the component method, i.e. global stiffness and strength were analytically-derived using simplified series of non-linear mechanical springs. Three-dimensional finite elements model was employed to investigate buckling of the fuse which might occur, during cycles, when up-lift displacement is recovering. In practical circumstances, it is recommend to design SHD devices of a CLT wall similarly to diagonal elements of steel bracings, i.e. neglecting the contribution of the compressed element. Finally, SHD is compared to traditionally-designed hold-down, which mostly dissipates (and fails) at steel-to-timber connection. Overall hysteretic response is somehow similar, although the inelastic mechanisms involved are different. For example, both the devices show pinching during cycles which for SHD is mainly caused by buckling of the fuse while, for traditional hold-down, is dominated by timber's embedment

    Influence of Specimen Geometry on the Response of Post-Installed Anchors Subjected to Constant Load under Crack Opening and Crack Cycles

    No full text
    It is generally acknowledged that one of the most critical tests to capture the behavior of a post-installed fastener under seismic action is the so-called “seismic crack movement test,” which consists in applying a constant load to a single fastener installed in a crack subjected to opening and full closing cycles. This article presents experimental results of crack movement tests on large size post-installed anchors that show a strong influence of the geometry of the concrete specimen in which the anchor is installed. To improve the regularity of the crack plane, a feedback control using the crack opening signal is applied to the servo-hydraulic actuators. Results of seismic crack movement tests using two different test setups were compared. The major aspects are as follows: (i) splitting force generated by the anchor affects the restoring of the zero crack opening when increasing the number of cycles, and (ii) increasing the size of concrete element limits the effects of bending induced in the concrete specimen. The issue of residual crack opening at the zero actuator’s load is observed experimentally and is further approached both analytically and numerically. The parameters that mostly affect the crack closure phase, i.e., steel ratio, transfer length, and de-bonding length, are finally discussed

    SEISMIC DESIGN AND EXPERIMENTAL INVESTIGATION OF A NEW TIMBER HOLD-DOWN CONNECTION

    No full text
    Timber connections made with hold-down are usually adopted for timber wall to foundation connection at the edges of the wall to restraint the possible overturning moment (due to rocking) which can occur by applying a horizontal force to the panel (e.g. under seismic action). The main components of the connection are the steel plate fastened to the panel via threaded screws or nails and the anchor system to the concrete foundation. As such, the connection behavior under seismic loading is characterized by the contemporarily contribution of different resistant mechanisms, i.e. (i) laterally loaded timber screws or nails; (ii) axially loaded steel plate; (iii) axially loaded anchor in concrete. The former has been basically neglected in past investigations having anchored the hold-down with steel bolt directly to the strong floor. However, the design of the anchor should be considered as crucial when it comes to capacity design, especially in case of narrow foundations (edge failure) and post-installed anchors when the resistance is highly reduced with respect to steel bolt capacity. Moreover, the overall dissipative performance might be affected by the anchor’s displacement. An innovative hold-down connection has been designed to promote steel failure of the axially loaded plate. The plate’s geometry has been optimized such that capacity design rules according to Eurocode 8 can be applied. Additionally, a target displacement requirement is addressed, and the stretch length is defined accordingly. The whole connection is tested against cyclic loading and results show enhanced performances with respect to standard configuration. In particular, brittle mechanism such as concrete-cone failure of the anchors and splitting of timber are prevented. The paper discusses the experimental results for different type and size of the anchor, also the size of the optimized steel plate is considered as a parameter

    Comparison of post-installed and cast-in rebars under monotonic and cyclic loads

    No full text
    In current design practice post - installed rebars are widely used in structural applications. Their design rules are limited by international codes to the performance of the corresponding cast-in reinforcement bars, albeit they show a higher bond strength. Moreover, the use of straight bars is definitely forbidden in dissipation zone such as beam-to-column joints. The presented paper is intended to assess the performance of cast-in and post-installed rebars designed according to reference codes under the application of cyclic and monotonic loads. To this purpose, experimental tests using a modified beam-end specimen were performed. Two different diameters were selected (db = 12, 16 mm); bonding lengths were determined to account for the promotion of steel failure. Cyclic tests were conducted by applying a repeated stepwise increasing load history (up to fifty-nine repetitions), adapted from test protocols used in the seismic assessment of post-installed anchors

    Haunch retrofit of RC beam–column joints: Linear stress field analysis and Strut-and-Tie method application

    Full text link
    This paper addresses the stress field of reinforced concrete (RC) beam–column joints retrofitted with haunches. Design of such solution currently assumes internal forces evaluated by the so called β-factor approach, which was originally conceived targeting the enhancement of steel moment-resisting frames. Extension to RC is subsequent as it emerges from the literature survey. The analytical model is first critically rediscussed. Inconsistencies of the adopted structural scheme, with respect to the actual mechanical behavior, may lie on the compatibility conditions which are imposed between the haunch and concrete beam (or column). In this regard, two-dimensional finite element models (FEM), using linear-elastic materials, are employed to study the stress field of two benchmark specimens derived from literature. A partial validation is carried out against experimentally derived internal forces. Results show that, for haunches with extended flat plates and stiff diagonals, compressive diffusion affects the entire haunch region. Consequently, beam's kinematic hypothesis of linear strains is no longer valid. The predicted joint shear demand resulted underestimated by β-factor approach by 50%. Since 2D FEM may be not efficient for many practical circumstances, an application of Strut-and-Tie is alternatively proposed. Finally, both the limitations and possible extensions of the proposed approaches are stated transparently

    RC Beam-Column Joints as Membrane Elements: An Application of MCFT

    No full text
    This paper addresses the evaluation of resistance of Reinforced Concrete (RC) beam-column joints by applying the Modified Compression Field Theory (MCFT). First, non-linear FEM analysis are used to discuss the stress field of the joint panel when the beam-column sub-assemblage is subjected to seismic loading. Benchmarks are considered from literature to validate the numerical models. Second, domain reduction is made by assimilating the joint panel to an isolated RC membrane subjected to shear and compressive stresses. Third, MCFT is applied to the reduced joint panel by using the freeware software Membrane 2000, developed at the University of Toronto. Finally, the obtained results are compared both to the first and second Level of Approximation design methods, to evaluate the joint shear strength, recently proposed by Fardis and included in the draft of the fib Model Code 2020

    RC beam-column joints, discussion of the provisions in the second generation Eurocode 8

    Full text link
    This paper reviews the provisions given in the draft of the second-generation Eurocode 8 (EC8) for the design and assessment of RC beam-column joint against seismic conditions. The analytical bases were recently published by Michael Fardis. A critical discussion of the analytical models, supported by a numerical example, is given. Validation against an independent database of exterior joints is made. A final comparison with respect to (i) current EC8 provisions and (ii) other Building Codes is presented

    Comparative Assessment of Shear Demand for RC Beam-Column Joints under Earthquake Loading

    Full text link
    This paper focuses on the evaluation of bi-axial shear demand for reinforced concrete (RC) beam–column joints assuming: (i) the SPEAR frame as a benchmark; and (ii) different structural analysis methods which share the same seismic input. A numerical model was implemented using lumped plasticity. The joints were modeled as rigid offsets of beams and columns. The shear demand at a joint is evaluated as a post-process of the beam’s nodal moment. The discussion focuses on the differences between the estimated shear demand considering modal-response-spectrum analysis (MRSA), non-linear static analysis (NLSA) and non-linear time history (NLTH). Strength assessment of joints is discussed as well. Significant strength differences were recognized by using different building codes targeted to existing structures which, in general, behaved on the safe side. The elliptical shear strength domain resulted in being conservative when compared to NLTH shear demand orbits. NLSA, using modal combination, proved to estimate the larger shear demand with respect to MRSA and NLTH

    Influence of head-size on concrete cone capacity: A comparison for two cast-in solutions

    No full text
    The request of flexibility coupled with the complexity of modern buildings has gradually moved the construction practice toward post-installed fasteners. However, there are structural applications, in which cast-in place anchors are still preferred. Headed studs are a common cast-in solution, which transfers the applied load to the base material mainly by bearing. In literature, it was found how increasing of the head-size leads to an increasing of the ultimate load but with reduced displacement capacity. Within this context, the influence of the head-size on concrete cone capacity was investigated for two cast-in solutions. Experimental tests and numerical analyses are discussed, accounting for the differences in the strain gradient in correspondence of the bearing head

    Experimental investigation of 3d RC exterior joint retrofitted with fully-fastened-haunch-retrofit-solution

    Full text link
    In recent years, the use of post-installed anchors to connect the haunch elements with the structural members has been investigated proficiently. It represents a promising alternative for strengthening of joints of existing reinforce concrete (RC) structures (moment resisting frames) with low invasion. The efficacy of the fully-fastened-haunch-retrofit (FFHR) solution has been proven by past works for two-dimensional RC beam-to-column joints, subjected to cyclic loading, without transverse beam and slab. In these cases, the presence of the haunch, providing a suitable design of the anchoring system, modifies the strength hierarchy shifting the mode of failure from joint's shear breakout to the formation of the plastic hinge in the beam. However, due to the presence of the slab and transverse beam, as the authors discussed elsewhere, an increase both (i) in the joint resistance and (ii) in the beam flexural resistance must be expected, but particular care must be taken to the non-symmetric behavior. In this regard, results obtained for two RC beam-to-column sub-assemblies with transverse beam and slab retrofitted using FFHR are presented. The structural behavior under cyclic load is compared with the as-built identical specimen. The applicability of the FFHR to existing RC structures, is confirmed but, at high level of ductility demand, both anchorage break-down and reduced displacement capacity are observed